This paper describes the most important results of a theoretical, experimental and in situ investigation developed in connection with a water supply pumping pipeline failure. This incident occurred after power failure of the pumping system that caused the burst of a prestressed concrete cylinder pipe (PCCP). Subsequently, numerous hydraulic transient simulations for different scenarios and various air pockets combinations were carried out in order to fully validate the diagnostic. As a result, it was determined that small air pocket volumes located along the pipeline profile were recognized as the direct cause of the PCCP rupture. Further, a detail survey of the pipeline was performed using a combination of non-destructive technologies in order to determine if immediate intervention was required to replace PCC pipes. In addition, a hydraulic model was employed to analyze the behavior of air pockets located at high points of the pipeline.
This paper presents numerical and experimental investigations of the combined effect on pressure transients of air pockets and homogenous water–air bubble mixtures. An air pocket can accumulate at a high point of a pipeline along the control section located at the transition between pipes with sub- and supercritical slope, forcing open channel flow conditions underneath the pocket that ends in a hydraulic jump at the downward sloping pipe. The turbulence action at the jump generates small air bubbles that are entrained and transported along the pipe producing a two-component bubbly flow within the continuous liquid phase. A numerical model is developed, combining the explicit–implicit scheme proposed by McGuire and Morris and the method of characteristics for solving the quasi-linear hyperbolic partial differential equations for transient two-phase flow expressed in conservation form. To verify the proposed model, an experimental apparatus made of PVC was used to carry out hydraulic transient experiments. Tests were conducted in a tank–pipe–valve system and a valve with a pneumatic actuator at the downstream end generated transients. Numerical results at the test section pipe compares favorably with experimental data. The results show that pressure transients are significantly reduced with increasing air-pocket volumes and bubbly flow air content.
Crest piers placed on overflow spillways induce standing waves at the downstream end of them and the supercritical flow expands after flowing past the rear of the pier. The expanding flow from each side of a pier will intersect and form disturbances or shock waves that travel laterally as they move downstream and eventually reach the chute sidewalls. Recently, investigations regarding crest piers are related with artificial aeration on stepped spillways to eliminate the risk of cavitation damage. However, there is a lack of studies on standing and shock waves in smooth spillways concerning the air entrainment into the flow in presence of crest piers. This paper presents the study of the combined effect on air entrainment of a crest pier and an aerator on the bottom of a smooth spillway (configuration 1). For comparison, experimental tests were developed in the spillway without pier, that is in presence of aerator only (configuration 2). The configuration 1 results show that the air concentration distribution on the spillway bottom across the width and length of the chute increases in comparison with configuration 2, reducing even more the risk of cavitation damage and enhancing the safety of the hydraulic structure.
This paper presents a case study of an existing wastewater rising main (WWRM) in which an extreme transient event produced by simultaneous power failure of the pumps caused the rupture of a 1.2 m (48 in) prestressed concrete cylinder pipe (PCCP), causing an important leakage of sewage. The event and the methodology followed in order to validate the diagnostics of the failure are described. The detail study included in situ observation of the system, experimental investigation in a setup, hydraulic analysis, as well as details of the structural strength of the WWRM. After the extensive investigation and several simulations of fluid transients for different scenarios and flow conditions, it was found that stationary small gas pockets accumulated at high points of the WWRM were identified as the principal contributory factor of the failure. This case study serves as clear warning of the consequences of operating a WWRM with gas pockets at its high points.
This paper examines the dual impact of trapped air on fluid transients in pressurised conduits, highlighting both its beneficial and detrimental impacts. This research analyses transient pressures caused by rapid valve closure in pipelines that contain air pockets and small bubbles dispersed within the liquid phase, by a hydraulic jump occurring at the downstream edge of the pockets. Experiments and numerical simulations were conducted with the valve positioned at the ends of the test section on both the inflow and outflow sides. A numerical model utilising the four-point centred scheme and method of characteristics was developed to resolve the governing equations of two-phase flow and was experimentally validated. The results indicate that entrapped air significantly influences hydraulic transients. When the valve is positioned downstream, air pockets and bubbles reduce pressure transients, illustrating a favourable effect. Conversely, when the valve is positioned upstream, adverse pressure transients occur, highlighting a detrimental impact. These outcomes underscore the importance of considering trapped air in pipeline systems, as its existence can either mitigate or exacerbate transient pressures depending on the configuration of the pipeline. The research highlights the significance of considering entrapped air in the design and evaluation of pressurised conduits to improve performance and prevent adverse effects.
This paper presents a case study of an existing water pipeline with five pumping stations each equipped with five pumps. In order to study the pipeline behavior prior to putting the system into operation, several transient simulations for different scenarios were developed. Results revealed that the most serious situation occurred when a simultaneous failure of the five pumps occur at each station caused by power cut, producing negative pressure waves because the system for control of hydraulic transients of the pipeline was insufficient to suppress downsurge pressures, due to the moment of inertia of all the pumps being erroneously considered during the design stage. The necessity to start supplying water to the population led to attempt an unconventional form of protecting the line against low pressures. The solution was to operate two of the five pumps per plant, and permit air to enter through combination air valves located along the pipeline. Air entrained formed pockets that remained stationary at the air valves locations, acting as air cushions that absorbed the energy of transient pressure waves. Computational simulations were conducted considering that two pumps are in operation at each plant and suddenly these fail simultaneously caused by power failure. The program was verified by comparing the calculated results with those registered during field pressure measurements. It was noticed that the surge modelling results are in good agreement with the measured data; furthermore, these show the air pockets in combination with existing devices for transient control protect the system adequately, avoiding potential damage to the pipeline.