Fumin Guo

Dr. Fumin Guo


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
RZRan Zhou
Ran Zhou
FGFumin Guo
Fumin Guo
MAM. Reza Azarpazhooh
M. Reza Azarpazhooh
SHSamineh Hashemi
Samineh Hashemi
XCXinyao Cheng
Xinyao Cheng
Aaron FensterAaron Fenster
Aaron Fenster
Measurement of total-plaque-area (TPA) is important for determining long term risk for stroke and monitoring carotid plaque progression. Since delineation of carotid plaques is required, a deep learning method can provide automatic plaque segmentations and TPA measurements; however, it requires large datasets and manual annotations for training with unknown performance on new datasets. A UNet++ ensemble algorithm was proposed to segment plaques from 2D carotid ultrasound images, trained on three small datasets (n = 33, 33, 34 subjects) and tested on 44 subjects from the SPARC dataset (n = 144, London, Canada). The ensemble was also trained on the entire SPARC dataset and tested with a different dataset (n = 497, Zhongnan Hospital, China). Algorithm and manual segmentations were compared using Dice-similarity-coefficient (DSC), and TPAs were compared using the difference (ΔTPA), Pearson correlation coefficient (r) and Bland-Altman analyses. Segmentation variability was determined using the intra-class correlation coefficient (ICC) and coefficient-of-variation (CoV). For 44 SPARC subjects, algorithm DSC was 83.3-85.7%, and algorithm TPAs were strongly correlated (r = 0.985-0.988; p <; 0.001) with manual results with marginal biases (0.73-6.75) mm$^2$ using the three training datasets. Algorithm ICC for TPAs (ICC = 0.996) was similar to intra- and inter-observer manual results (ICC = 0.977, 0.995). Algorithm CoV = 6.98% for plaque areas was smaller than the inter-observer manual CoV (7.54%). For the Zhongnan dataset, DSC was 88.6% algorithm and manual TPAs were strongly correlated (r = 0.972, p <; 0.001) with ΔTPA = -0.44±4.05 mm$^2$ and ICC = 0.985. The proposed algorithm trained on small datasets and segmented a different dataset without retraining with accuracy and precision that may be useful clinically and for research.

29 December 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MNMatthew Ng
Matthew Ng
FGFumin Guo
Fumin Guo
LBLabonny Biswas
Labonny Biswas
SPSteffen Petersen
Steffen Petersen
SPStefan K. Piechnik
Stefan K. Piechnik
GWGraham Wright
Graham Wright
Objective: Convolutional neural networks (CNNs) have demonstrated promise in automated cardiac magnetic resonance image segmentation. However, when using CNNs in a large real-world dataset, it is important to quantify segmentation uncertainty and identify segmentations which could be problematic. In this work, we performed a systematic study of Bayesian and non-Bayesian methods for estimating uncertainty in segmentation neural networks. Methods: We evaluated Bayes by Backprop, Monte Carlo Dropout, Deep Ensembles, and Stochastic Segmentation Networks in terms of segmentation accuracy, probability calibration, uncertainty on out-of-distribution images, and segmentation quality control. Results: We observed that Deep Ensembles outperformed the other methods except for images with heavy noise and blurring distortions. We showed that Bayes by Backprop is more robust to noise distortions while Stochastic Segmentation Networks are more resistant to blurring distortions. For segmentation quality control, we showed that segmentation uncertainty is correlated with segmentation accuracy for all the methods. With the incorporation of uncertainty estimates, we were able to reduce the percentage of poor segmentation to 5% by flagging 31–48% of the most uncertain segmentations for manual review, substantially lower than random review without using neural network uncertainty (reviewing 75–78% of all images). Conclusion: This work provides a comprehensive evaluation of uncertainty estimation methods and showed that Deep Ensembles outperformed other methods in most cases. Significance: Neural network uncertainty measures can help identify potentially inaccurate segmentations and alert users for manual review.

1 April 2020 in Medical Image Analysis
Verified
Journal Article
Closed access
FGFumin Guo
Fumin Guo
MNMatthew Ng
Matthew Ng
MGMaged Goubran
Maged Goubran
SPSteffen Petersen
Steffen Petersen
SPStefan K. Piechnik
Stefan K. Piechnik
GWGraham Wright
Graham Wright

28 February 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
RZRan Zhou
Ran Zhou
FGFumin Guo
Fumin Guo
MAM. Reza Azarpazhooh
M. Reza Azarpazhooh
JSJ. David Spence
J. David Spence
EUEranga Ukwatta
Eranga Ukwatta
Aaron FensterAaron Fenster
Aaron Fenster
Vessel-wall-volume (VWV) is an important three-dimensional ultrasound (3DUS) metric used in the assessment of carotid plaque burden and monitoring changes in carotid atherosclerosis in response to medical treatment. To generate the VWV measurement, we proposed an approach that combined a voxel-based fully convolution network (Voxel-FCN) and a continuous max-flow module to automatically segment the carotid media-adventitia (MAB) and lumen-intima boundaries (LIB) from 3DUS images. Voxel-FCN includes an encoder consisting of a general 3D CNN and a 3D pyramid pooling module to extract spatial and contextual information, and a decoder using a concatenating module with an attention mechanism to fuse multi-level features extracted by the encoder. A continuous max-flow algorithm is used to improve the coarse segmentation provided by the Voxel-FCN. Using 1007 3DUS images, our approach yielded a Dice-similarity-coefficient (DSC) of 93.2±3.0% for the MAB in the common carotid artery (CCA), and 91.9±5.0% in the bifurcation by comparing algorithm and expert manual segmentations. We achieved a DSC of 89.5±6.7% and 89.3±6.8% for the LIB in the CCA and the bifurcation respectively. The mean errors between the algorithm- and manually-generated VWVs were 0.2±51.2 mm3 for the CCA and -4.0±98.2 mm3 for the bifurcation. The algorithm segmentation accuracy was comparable to intra-observer manual segmentation but our approach required less than 1s, which will not alter the clinical work-flow as 10s is required to image one side of the neck. Therefore, we believe that the proposed method could be used clinically for generating VWV to monitor progression and regression of carotid plaques.

16 July 2022 in Medical Image Analysis
Verified
Journal Article
Closed access
FGFumin Guo
Fumin Guo
MNMatthew Ng
Matthew Ng
GKGrey Kuling
Grey Kuling
GWGraham Wright
Graham Wright

1 February 2021 in Radiology
Verified
Journal Article
Closed access
DCDante Capaldi
Dante Capaldi
FGFumin Guo
Fumin Guo
LXLei Xing
Lei Xing
GPGrace Parraga
Grace Parraga
In participants with diverse pulmonary pathologic findings, a deep learning approach generated pulmonary ventilation maps from free-breathing proton MRI that showed a strong correlation with noble ... Background Hyperpolarized noble gas MRI helps measure lung ventilation, but clinical translation remains limited. Free-breathing proton MRI may help quantify lung function using existing MRI system...