Martin Bucher

Dr. Martin Bucher

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2022 in Radiation
Verified
Journal Article
Open access
PDF file
DHDaniela Hladik
Daniela Hladik
MBMartin Bucher
Martin Bucher
DEDavid Endesfelder
David Endesfelder
UOUrsula Oestreicher
Ursula Oestreicher
Biological dosimetry is an internationally recognized method for quantifying and estimating radiation dose following suspected or verified excessive exposure to ionising radiation. In severe radiation accidents where a large number of people are potentially affected, it is possible to distinguish irradiated from non-irradiated people in order to initiate appropriate medical care if necessary. In addition to severe incidents caused by technical failure, environmental disasters, military actions, or criminal abuse, there are also radiation accidents in which only one or a few individuals are affected in the frame of occupational or medical exposure. The requirements for biological dosimetry are fundamentally different for these two scenarios. In particular, for large-scale radiation accidents, pre-screening methods are necessary to increase the throughput of samples for a rough first-dose categorization. The rapid development and increasing use of omics methods in research as well as in individual applications provides new opportunities for biological dosimetry. In addition to the discovery and search for new biomarkers, dosimetry assays based on omics technologies are becoming increasingly interesting and hold great potential, especially for large-scale dosimetry. In the following review, the different areas of biological dosimetry, the problems in finding suitable biomarkers, the current status of biomarker research based on omics, the potential applications of assays using omics technologies, and also the limitations for the different areas of biological dosimetry are discussed.

14 February 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MBMartin Bucher
Martin Bucher
DEDavid Endesfelder
David Endesfelder
SPStefan Pojtinger
Stefan Pojtinger
ABAns Baeyens
Ans Baeyens
JBJoan-Francesc Barquinero
Joan-Francesc Barquinero
UOUrsula Oestreicher
Ursula Oestreicher
In previous RENEB interlaboratory comparisons based on the manual scoring of dicentric chromosomes, a tendency for systematic overestimation for doses > 2.5 Gy was found. However, these exercises included only very few doses in the high dose range, and they were heterogeneous in terms of radiation quality and evaluation mode, and comparable only to a limited extent. Here, this presumed deviation was explored by investigating three doses > 2.5 Gy. Blood samples were irradiated (2.56, 3.41 and 4.54 Gy) using a 60Co source and sent to 14 member laboratories of the RENEB network, which performed the dicentric chromosome assay (manual and/or semi-automatic scoring) and reported dose estimates. Most participants provided estimates that agreed very well with the physical reference doses and all provided dose estimates were in the correct clinical category (> 2 Gy). The previously observed tendency for a systematic bias across all laboratories was not confirmed. However, tendencies for systematic underestimation were detected for dose estimations for reference doses given in terms of absorbed dose to blood and for some participants, a laboratory-specific trend of systematic under- or overestimation was observed. The importance of regularly performed quality checks for a broad dose range became obvious to avoid misinterpretation of results.

1 January 2021 in Mutation Research - Genetic Toxicology and Environmental Mutagenesis
Verified
Journal Article
Open access
MBMartin Bucher
Martin Bucher
DEDavid Endesfelder
David Endesfelder
URUte Roessler
Ute Roessler
ABArndt Borkhardt
Arndt Borkhardt
GDGregor Dückers
Gregor Dückers
MGMaria Gomolka
Maria Gomolka
Ataxia-telangiectasia (AT) is a rare inherited recessive disorder which is caused by a mutated Ataxia-telangiectasia mutated (ATM) gene. Hallmarks include chromosomal instability, cancer predisposition and increased sensitivity to ionizing radiation. The ATM protein plays an important role in signaling of DNA double-strand breaks (DSB), thereby phosphorylating the histone H2A.X. Non-functional ATM protein leads to defects in DNA damage response, unresolved DSBs and genomic instability. The aim of this study was to evaluate chromosomal aberrations and γH2A.X foci as potential radiation sensitivity biomarkers in AT patients. For this purpose, lymphocytes of 8 AT patients and 10 healthy controls were irradiated and induced DNA damage and DNA repair capacity were detected by the accumulation of γH2A.X foci. The results were heterogeneous among AT patients. Evaluation revealed 2 AT patients with similar γH2A.X foci numbers as controls after 1 h while 3 patients showed a lower induction. In regard to DNA repair, 3 of 5 AT patients showed poor damage repair. Therefore, DNA damage induction and DNA repair as detected by H2A.X phosphorylation revealed individual differences, seems to depend on the underlying individual mutation and thus appears not well suited as a biomarker for radiation sensitivity. In addition, chromosomal aberrations were analyzed by mFISH. An increased frequency of spontaneous chromosomal breakage was characteristic for AT cells. After irradiation, significantly increased rates for non-exchange aberrations, translocations, complex aberrations and dicentric chromosomes were observed in AT patients compared to controls. The results of this study suggested, that complex aberrations and dicentric chromosomes might be a reliable biomarker for radiation sensitivity in AT patients, while non-exchange aberrations and translocations identified both, spontaneous and radiation-induced chromosomal instability.

18 April 2023 in Cytogenetic and Genome Research
Verified
Journal Article
Closed access
PDF file
DEDavid Endesfelder
David Endesfelder
UKUlrike Kulka
Ulrike Kulka
MBMartin Bucher
Martin Bucher
UGUlrich Giesen
Ulrich Giesen
GGGuy Garty
Guy Garty
UOUrsula Oestreicher
Ursula Oestreicher
In the case of a radiological or nuclear event, biological dosimetry can be an important tool to support clinical decision-making. During a nuclear event, individuals might be exposed to a mixed field of neutrons and photons. The composition of the field and the neutron energy spectrum influence the degree of damage to the chromosomes. During the transatlantic BALANCE project, an exposure similar to a Hiroshima-like device at a distance of 1.5 km from the epicenter was simulated, and biological dosimetry based on dicentric chromosomes was performed to evaluate the participants ability to discover unknown doses and to test the influence of differences in neutron spectra. In a first step, calibration curves were established by irradiating blood samples with 5 doses in the range of 0–4 Gy at two different facilities in Germany (Physikalisch-Technische Bundesanstalt [PTB]) and the USA (the Columbia IND Neutron Facility [CINF]). The samples were sent to eight participating laboratories from the RENEB network and dicentric chromosomes were scored by each participant. Next, blood samples were irradiated with 4 blind doses in each of the two facilities and sent to the participants to provide dose estimates based on the established calibration curves. Manual and semiautomatic scoring of dicentric chromosomes were evaluated for their applicability to neutron exposures. Moreover, the biological effectiveness of the neutrons from the two irradiation facilities was compared. The calibration curves from samples irradiated at CINF showed a 1.4 times higher biological effectiveness compared to samples irradiated at PTB. For manual scoring of dicentric chromosomes, the doses of the test samples were mostly successfully resolved based on the calibration curves established during the project. For semiautomatic scoring, the dose estimation for the test samples was less successful. Doses >2 Gy in the calibration curves revealed nonlinear associations between dose and dispersion index of the dicentric counts, especially for manual scoring. The differences in the biological effectiveness between the irradiation facilities suggested that the neutron energy spectrum can have a strong impact on the dicentric counts.

16 October 2021 in Medical Physics
Verified
Journal Article
Open access
PDF file
MBMartin Bucher
Martin Bucher
STSebastian Trinkl
Sebastian Trinkl
DEDavid Endesfelder
David Endesfelder
TWTina Weiss
Tina Weiss
MGMaria Gomolka
Maria Gomolka
AGAugusto Giussani
Augusto Giussani
Purpose: X‐ray cabinets are replacing 137Cs/60Co sources in radiation biology research due to advantages in size, handling, and radiation protection. However, because of their different physical properties, X‐ray cabinets are more susceptible to experimental influences than conventional sources. The aim of this study was to examine the variations related to the experimental setups typically used to investigate biological radiation effects with X‐ray cabinets.Materials and methods: A combined approach of physical dose measurements by thermoluminescence dosimetry and detection of biological effects by quantification of γH2AX and 53BP1 foci was used to analyze field inhomogeneity and evaluate the influence of the components of the experimental setup.Results: Irradiation was performed using an X‐ray tube (195 kV, 10 mA, 0.5‐mm‐thick copper filter, dose rate of 0.59 Gy/min). Thermoluminescence dosimetry revealed inhomogeneity and a dose decrease of up to 42.3% within the beam area (diameter 31.1 cm) compared to the dose at the center. This dose decrease was consistent with the observed decline in the number of radiation‐induced foci by up to 55.9 %. Uniform dose distribution was measured after reducing the size of the radiation field (diameter 12.5 cm). However, when using 15‐ml test tubes placed at different positions within this field, the dose decreased by up to 17% in comparison to the central position. Analysis of foci number revealed significant differences between the tubes for γH2AX (1 h) and 53BP1 (4 h) at different time points after irradiation. Neither removal of some tubes nor of the caps improved the dose decrease significantly. By contrast, when using 1.5‐ml tubes, dose differences were less than 4%, and no significant differences in foci number were detected.Conclusion: X‐ray cabinets are user‐friendly irradiation units for investigating biological radiation effects. However, field inhomogeneities and experimental setup components considerably affect the delivered irradiation doses. For this reason, strict dosimetric monitoring of experimental irradiation setups is mandatory for reliable studies.

24 July 2020 in International Journal of Radiation Biology
Verified
Journal Article
Open access
MBMartin Bucher
Martin Bucher
LDLukas Duchrow
Lukas Duchrow
DEDavid Endesfelder
David Endesfelder
URUte Roessler
Ute Roessler
MGMaria Gomolka
Maria Gomolka
In case of population exposure by ionizing radiation, a fast and reliable dose assessment of exposed and non-exposed individuals is crucial important. In initial triage, physicians have to take fast decisions whom to treat with adequate medical care. In addition, worries about significant exposure can be taken away from hundreds to thousands non- or low exposed individuals. Studies have shown that the γH2A.X radiation-induced foci assay is a promising test for fast triage decisions. However, in a large-scale scenario most biodosimetry laboratories will quickly reach their capacity limit. The aim of this study was to evaluate the benefit of inexperienced experimenters to speed up the foci assay and manual foci scoring. The participants of two training courses performed the radiation-induced foci assay (γH2A.X) under the guidance of experts and scored foci (γH2A.X and 53BP1) on sham-irradiated and irradiated blood samples (0.05-1.5 Gy). The outcome of laboratory experiments and manual foci scoring by 26 operators with basic experience in laboratory work was statistically analyzed in comparison to the results from experts. Inexperienced operators prepared slides with significant dose-effects (0, 0.1 and 1.0 Gy) for semi-automatic microscopic analyses. Manual foci scoring by inexperienced scorer resulted in a dose-effect curve for γH2A.X, 53BP1 and co-localized foci. In addition, inexperienced scorers were able to distinguish low irradiation doses from unirradiated cells. While 53BP1 foci scoring was in accordance to the expert counting, differences between beginners and expert increased for γH2A.X or co-localized foci. In case of a large-scale radiation event, inexperienced staff is useful to support laboratories in slide preparation for semi-automatic foci counting as well as γH2A.X and 53BP1 manual foci scoring for triage-mode biodosimetry. Slides can be clearly classified in the non-, low- or high-exposed category.