Chiara Bregoli

Dr. Chiara Bregoli

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Monica TiboniMonica Tiboni
Monica Tiboni
Alberto BorboniAlberto Borboni
Alberto Borboni
FVFabien Vérité
Fabien Vérité
CBChiara Bregoli
Chiara Bregoli
Cinzia AmiciCinzia Amici
Cinzia Amici
Exoskeletons are robots that closely interact with humans and that are increasingly used for different purposes, such as rehabilitation, assistance in the activities of daily living (ADLs), performance augmentation or as haptic devices. In the last few decades, the research activity on these robots has grown exponentially, and sensors and actuation technologies are two fundamental research themes for their development. In this review, an in-depth study of the works related to exoskeletons and specifically to these two main aspects is carried out. A preliminary phase investigates the temporal distribution of scientific publications to capture the interest in studying and developing novel ideas, methods or solutions for exoskeleton design, actuation and sensors. The distribution of the works is also analyzed with respect to the device purpose, body part to which the device is dedicated, operation mode and design methods. Subsequently, actuation and sensing solutions for the exoskeletons described by the studies in literature are analyzed in detail, highlighting the main trends in their development and spread. The results are presented with a schematic approach, and cross analyses among taxonomies are also proposed to emphasize emerging peculiarities.

1 June 2024 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
CBChiara Bregoli
Chiara Bregoli
CBCarlo Alberto Biffi
Carlo Alberto Biffi
ATAusonio Tuissi
Ausonio Tuissi
FBFederica Buccino
Federica Buccino
Research at the mesoscale bone trabeculae arrangement yields intriguing results that, due to their clinical resolution, can be applied in clinical field, contributing significantly to the diagnosis of bone-related diseases. While the literature offers quantitative morphometric parameters for a thorough characterization of the mesoscale bone network, there is a gap in understanding relationships among them, particularly in the context of various bone pathologies. This research aims to bridge these gaps by offering a quantitative evaluation of the interplay among morphometric parameters and mechanical response at mesoscale in osteoporotic and non-osteoporotic bones. Bone mechanical response, dependent on trabecular arrangement, is defined by apparent stiffness, computationally calculated using the Gibson-Ashby model. Key findings indicate that: (i) in addition to bone density, measured using X-ray absorptiometry, trabecular connectivity density, trabecular spacing and degree of anisotropy are crucial parameters for characterize osteoporosis state; (ii) apparent stiffness values exhibit strong correlations with bone density and connectivity density; (iii) connectivity density and degree of anisotropy result the best predictors of mechanical response. Despite the inherent heterogeneity in bone structure, suggesting the potential benefit of a larger sample size in the future, this approach presents a valuable method to enhance discrimination between osteoporotic and non-osteoporotic samples. Graphical Abstract

7 May 2022 in Orthopaedic Surgery
Verified
Journal Article
Open access
CBChiara Bregoli
Chiara Bregoli
CBCarlo Alberto Biffi
Carlo Alberto Biffi
KMKavin Morellato
Kavin Morellato
EGEmanuele Gruppioni
Emanuele Gruppioni
MPMatteo Primavera
Matteo Primavera
ATAusonio Tuissi
Ausonio Tuissi
Digital trauma amputations and digital agenesis strongly affect the functionality and aesthetic appearance of the hand. Autologous reconstruction is the gold standard of treatment. Unfortunately, microsurgical options and transplantation procedures are not possible for patients who present contraindications or refuse to undergo transplantation from the toe (e.g. toe‐to‐thumb transplantation). To address these issues, osseointegrated finger prostheses are a promising alternative. The functional assessments registered during follow‐up confirmed the promising outcomes of osseointegrated prostheses in the treatment of hand finger amputees. This review outlines (a) a detailed analysis of osseointegrated finger metallic components of the implants, (b) the surgical procedures suggested in the literature, and (c) the functional assessments and promising outcomes that demonstrate the potential of these medical osseointegrated devices in the treatment of finger amputees.

23 March 2022 in Advanced Engineering Materials
Verified
Journal Article
Open access
CBCarlo Alberto Biffi
Carlo Alberto Biffi
JFJacopo Fiocchi
Jacopo Fiocchi
CBChiara Bregoli
Chiara Bregoli
SGSofia Gambaro
Sofia Gambaro
FCFrancesco Copes
Francesco Copes
ATAusonio Tuissi
Ausonio Tuissi
Biodegradable metallic alloys are promising materials for the development of temporary medical implants, including cardiovascular and orthopedic devices. The present work explores the surface modification of a biodegradable Fe–20Mn alloy by means of ultrashort laser texturing and the correlation between the laser‐induced surface morphology and the degradation behavior. In detail, the effect of different processing parameters on surface morphology is explored and compared with the unprocessed surface. It is found that laser texturing can tune the degradation rate, selectively inducing positive (+29%) or negative (−31%) change with respect to the untreated surface.

12 September 2024 in Materialia
Verified
Journal Article
Open access
CBChiara Bregoli
Chiara Bregoli
JFJacopo Fiocchi
Jacopo Fiocchi
Mehrshad MehrpouyaMehrshad Mehrpouya
Mehrshad Mehrpouya
LVLaura Maria Vergani
Laura Maria Vergani
ATAusonio Tuissi
Ausonio Tuissi
CBCarlo Alberto Biffi
Carlo Alberto Biffi

5 July 2023 in Medical Engineering & Physics
Verified
Journal Article
Closed access
CBChiara Bregoli
Chiara Bregoli
FSFederico Stacchiotti
Federico Stacchiotti
JFJacopo Fiocchi
Jacopo Fiocchi
RFRubens Ferrari
Rubens Ferrari
CBCarlo Alberto Biffi
Carlo Alberto Biffi
ATAusonio Tuissi
Ausonio Tuissi
Thumb amputations leads to 50 % loss in hand functionality. To date, silicone vacuum prosthesis and autologous transplantation are the most adopted treatment solutions: nevertheless, vacuum prostheses lack in stability and cause skin issue and surgical treatment is not always accepted by patients. Osseointegrated implants were demonstrated to enhance stability, restore osseoperception and increase the time of prosthesis use. Thumb amputations present varying stump sizes: a standard size implant cannot address specificity of each patient, while a patient matched solution can meet surgeon requirements, by geometrical features of implant. The fixture presented in the current paper is the first additively manufactured patient matched osseointegrated implant for the treatment of thumb amputees. The current work aims to verify and validate a predictive finite element model (FEM) for mechanical strength of the presented fixture. FEM was demonstrated to correctly evaluate the mechanical strength of patient matched device. Minimum strength requirements were calculated in different core diameters: FEM were experimentally validated. Safety factor of 1.5 was guaranteed. Finally, considerations on performance of the prototype were carried out by means of insertion tests in Sawbones and axial pull-out force assessment. Cadaver tests to evaluate the entire procedure and production process are ongoing.