A framework of "Common Criteria" (i.e. a series of questions) has been developed to inform the use and evaluation of biomonitoring data in the context of human exposure and risk assessment. The data-rich chemical benzene was selected for use in a case study to assess whether refinement of the Common Criteria framework was necessary, and to gain additional perspective on approaches for integrating biomonitoring data into a risk-based context. The available data for benzene satisfied most of the Common Criteria and allowed for a risk-based evaluation of the benzene biomonitoring data. In general, biomarker (blood benzene, urinary benzene and urinary S-phenylmercapturic acid) central tendency (i.e. mean, median and geometric mean) concentrations for non-smokers are at or below the predicted blood or urine concentrations that would correspond to exposure at the US Environmental Protection Agency reference concentration (30 µg/m(3)), but greater than blood or urine concentrations relating to the air concentration at the 1 × 10(-5) excess cancer risk (2.9 µg/m(3)). Smokers clearly have higher levels of benzene exposure, and biomarker levels of benzene for non-smokers are generally consistent with ambient air monitoring results. While some biomarkers of benzene are specific indicators of exposure, the interpretation of benzene biomonitoring levels in a health-risk context are complicated by issues associated with short half-lives and gaps in knowledge regarding the relationship between the biomarkers and subsequent toxic effects.
1 September 1995 in Occupational and Environmental Medicine
OBJECTIVES--Comparison of the suitability of two minor urinary metabolites of benzene, trans,trans-muconic acid (tt-MA) and S-phenylmercapturic acid (S-PMA), as biomarkers for low levels of benzene exposure. METHODS--The sensitivity of analytical methods of measuring tt-MA and S-PMA were improved and applied to 434 urine samples collected from 188 workers in 12 studies in different petrochemical industries and from 52 control workers with no occupational exposure to benzene. In nine studies airborne benzene concentrations were assessed by personal air monitoring. RESULTS--Strong correlations were found between tt-MA and S-PMA concentrations in samples from the end of the shift and between either of these variables and airborne benzene concentrations. It was calculated that exposure to 1 ppm (8 hour time weighted average (TWA)) benzene leads to an average concentration of 1.7 mg tt-MA and 47 micrograms S-PMA/g creatinine in samples from the end of the shift. It was estimated that, on average, 3.9% (range 1.9%-7.3%) of an inhaled dose of benzene was excreted as tt-MA with an apparent elimination half life of 5.0 (SD 2.3) hours and 0.11% (range 0.05%-0.26%) as S-PMA with a half life of 9.1 (SD 3.7) hours. The mean urinary S-PMA in 14 moderate smokers and 38 non-smokers was 3.61 and 1.99 micrograms/g creatinine, respectively and the mean urinary tt-MA was 0.058 and 0.037 mg/g creatinine, respectively. S-PMA proved to be more specific and more sensitive (P = 0.030, Fisher's exact test) than tt-MA. S-PMA, but not tt-MA, was always detectable in the urine of smokers who were not occupationally exposed. S-PMA was also detectable in 20 of the 38 non-smokers from the control group whereas tt-MA was detectable in only nine of these samples. The inferior specificity of tt-MA is due to relatively high background values (up to 0.71 mg/g creatinine in this study) that may be found in non-occupationally exposed people. CONCLUSIONS--Although both tt-MA and S-PMA are sensitive biomarkers, only S-PMA allows reliable determination of benzene exposures down to 0.3 ppm (8 h TWA) due to its superior specificity. Because it has a longer elimination half life S-PMA is also a more reliable biomarker than tt-MA for benzene exposures during 12 hour shifts. For biological monitoring of exposure to benzene concentrations higher than 1 ppm (8 h TWA) tt-MA is also suitable and may even be preferred due to its greater ease of measurement.
1 August 2008 in Regulatory Toxicology and Pharmacology
1,3-Butadiene (BD) is carcinogenic in mice and rats, with mice being considerably more sensitive than rats. Urine metabolites are 1,2-dihydroxybutyl mercapturic acid (DHBMA) and a mixture of monohydroxy-3-butenyl mercapturic acids (MHBMA). The reactive metabolite 1,2-epoxy-3-butene forms 1- and 2-hydroxy-3-butenyl valine adducts in hemoglobin (MHBVal). The objectives of the study were (1) to compare the suitability of MHBMA, DHBMA, and MHBVal as biomarkers for low levels of exposure to BD, and (2) to explore relative pathways of metabolism of BD in humans for comparison with mice and rats, which is important in relation to cancer risk assessment in man. Analytical methods of measuring MHBMA, DHBMA, and MHBVal were modified and applied in 2 studies to workers engaged in the manufacture and use of BD. Airborne BD concentrations were assessed by personal air monitoring. MHBMA in urine was more sensitive for monitoring recent exposures to BD when compared to DHBMA and could measure 8-h time weighted average exposures as low as 0.13 ppm. Relatively high natural background levels in urine restricted the sensitivity of DHBMA. The origin of this background is currently unknown. The measurement of MHBVal adducts in hemoglobin was a sensitive method for monitoring cumulative exposures to BD at or above 0.35 ppm. Statistically significant relationships were found between urinary MHBMA and DHBMA concentrations, between either of these variables and 8-h airborne BD levels and between MHBVal adducts and average airborne BD levels over 60 days. The data on biomarkers demonstrated a much higher rate of hydrolytic metabolism of 1,2-epoxy-3-butene in humans compared to mice and rats, which was reflected in a much higher DHBMA/(DHBMA + MHBMA) ratio and in much lower levels of MHBVal in humans. Assuming a genotoxic mechanism, the data of this study, coupled with other published data on DNA and hemoglobin binding in mice and rats, suggest that the cancer risk for man from exposure to BD is expected to be less than for the rat and much less than for the mouse.
11 September 2009 in Critical Reviews in Toxicology
The formation of deoxyribonucleic acid (DNA) adducts can have important and adverse consequences for cellular and whole organism function. Available methods for identification of DNA damage and quantification of adducts are reviewed. Analyses can be performed on various samples including tissues, isolated cells, and intact or hydrolyzed (digested) DNA from a variety of biological samples of interest for monitoring in humans. Sensitivity and specificity are considered key factors for selecting the type of method for assessing DNA perturbation. The amount of DNA needed for analysis is dependent upon the method and ranges widely, from <1 microg to 3 mg. The methods discussed include the Comet assay, the ligation-mediated polymerase reaction, histochemical and immunologic methods, radiolabeled ((14)C- and (3)H-) binding, (32)P-postlabeling, and methods dependent on gas chromatography (GC) or high-performance liquid chromatography (HPLC) with detection by electron capture, electrochemical detection, single or tandem mass spectrometry, or accelerator mass spectrometry. Sensitivity is ranked, and ranges from approximately 1 adduct in 10(4) to 10(12) nucleotides. A brief overview of oxidatively generated DNA damage is also presented. Assay limitations are discussed along with issues that may have impact on the reliability of results, such as sample collection, processing, and storage. Although certain methodologies are mature, improving technology will continue to enhance the specificity and sensitivity of adduct analysis. Because limited guidance and recommendations exist for adduct analysis, this effort supports the HESI Committee goal of developing a framework for use of DNA adduct data in risk assessment.