In this paper, a passive structural health monitoring (SHM) method capable of detecting the presence of damage in carbon fibre/epoxy composite plates is developed. The method requires the measurement of strains from the considered structure, which are used to set up, train, and test artificial neural networks (ANNs). At the end of the training phase, the networks find correlations between the given strains, which represent the ‘fingerprint’ of the structure under investigation. Changes in the distribution of these strains is captured by assessing differences in the previously identified strain correlations. If any cause generates damage that alters the strain distribution, this is considered as a reason for further detailed structural inspection. The novelty of the strain algorithm comes from its independence from both the choice of material and the loading condition. It does not require the prior knowledge of material properties based on stress-strain relationships and, as the strain correlations represent the structure and its mechanical behaviour, they are valid for the full range of operating loads. An implementation of such approach is herein presented based on the usage of a distributed optical fibre sensor that allows to obtain strain measurement with an incredibly high resolution.
Studying, controlling and extrapolating the indoor microclimate of historical buildings have always been at the forefront among numerous preventive conservation strategies, especially in case of buildings made of organic hygroscopic materials, e.g., wood. The variations and fluctuations of the microclimatic variables, namely temperature (T) and relative humidity (RH), could have a detrimental effect on the mechanical properties of wooden objects, works of art and structures. For this reason, through the years, several guidelines have been provided by standards and protocols about the optimal microclimatic conditions that should be ensured to avoid the decay and the eventual catastrophic failure of heritage objects and buildings. In this work, two historical buildings entirely made of Scots pine wood have been analysed: the Ringebu and Heddal stave churches (Norway). These churches store several wooden medieval statues and paintings that are also susceptible to the effects of the microclimate. For this reason, the timeseries of the indoor relative humidity of the two churches have been analysed, in the framework of the indications provided by the standards. The criticalities of the existing protocols have been pointed out, emphasizing the need for systematically and periodically updated specifications, tailorable to a given case study of concern, without forgetting the ever-present needs of energy- and money-saving approaches.