Left ventricular assist device (LVAD) use has continued to grow. Despite recent advances in technology, LVAD patients continue to suffer from devastating complications, including stroke and device thrombosis. Among several variables affecting thrombogenicity, we hypothesize that insertion depth of the inflow cannula into the left ventricle (LV) influences hemodynamics and thrombosis risk. Blood flow patterns were studied in a patient-derived computational model of the LV, mitral valve (MV), and LVAD inflow cannula using unsteady computational fluid dynamics (CFD). Hundreds of thousands of platelets were tracked individually, for two inflow cannula insertion depth configurations (12 mm—reduced and 27 mm—conventional) using platelet-level (Lagrangian) metrics to quantify thrombogenicity. Particularly in patients with small LV dimensions, the deeper inflow cannula insertion resulted in much higher platelet shear stress histories (SH), consistent with markedly abnormal intraventricular hemodynamics. A larger proportion of platelets in this deeper insertion configuration was found to linger in the domain for long residence times (RT) and also accumulated much higher SH. The reduced inflow depth configuration promoted LV washout and reduced platelet SH. The increase of both SH and RT in the LV demonstrates the impact of inflow cannula depth on platelet activation and increased stroke risk in these patients. Inflow cannula depth of insertion should be considered as an opportunity to optimize surgical planning of LVAD therapy.
Objective: To develop a new method for the prediction of interface pressure applied by medical compression bandages Methods: A finite element simulation of bandage application was designed, based on patient-specific leg geometries. For personalized interface pressure prediction, a model reduction approach was proposed, which included the parameterization of the leg geometry. Pressure values computed with this reduced model were then confronted to experimental pressure values. Results: The most influencing parameters were found to be the bandage tension, the skin-to-bandage friction coefficient and the leg morphology. Thanks to the model reduction approach, it was possible to compute interface pressure as a linear combination of these parameters. The pressures computed with this reduced model were in agreement with experimental pressure values measured on 66 patients' legs. Conclusion: This methodology helps to predict patient-specific interface pressure applied by compression bandages within a few minutes whereas it would take a few days for the numerical simulation. The results of this method show less bias than Laplace's Law, which is for now the only other method for interface pressure computation.
Flow in sidewall cerebral aneurysms can be ideally modelled as the combination of flow over a spherical cavity and flow in a curved circular pipe, two canonical flows. Flow in a curved pipe is known to depend on the Dean number in the free stream. The circulation in the cavity was higher for steady inflow than for the equivalent average Reynolds number and Dean number pulsatile inflow, with very limited impact of the Womersley number in the range studied. A second part of this study, that focuses on the changes in fluid dynamics when the intracranial aneurysm is treated with a flow-diverting stent, can be found in this issue (Barbour et al., J. Fluid Mech., vol. 915, 2021, A124).
The flow in a spherical cavity on a curved round pipe is a canonical flow that describes well the flow inside a sidewall aneurysm on an intracranial artery. Intracranial aneurysms are often treated with a flow-diverting stent (FDS), a low-porosity metal mesh that covers the entrance to the cavity, to reduce blood flow into the aneurysm sac and exclude it from mechanical stresses imposed by the blood flow. Successful treatment is highly dependent on the degree of reduction of flow inside the cavity, and the resulting altered fluid mechanics inside the aneurysm following treatment. Using stereoscopic particle image velocimetry, we characterize the fluid mechanics in a canonical configuration representative of an intracranial aneurysm treated with a FDS: a spherical cavity on the side of a curved round pipe covered with a metal mesh formed by an actual medical FDS. This porous mesh coverage is the focus of Part 2 of the paper, characterizing the effects of parent vessel , and this can be a fluid mechanics criterion to guide treatment selection.