S.M. Hamidi

Prof. S.M. Hamidi


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2022 in Optical Materials Express
Verified
Journal Article
Closed access
MCMohammad Javad Haji Najafi Chemerkouh
Mohammad Javad Haji Najafi Chemerkouh
SSSeyedeh Bita Saadatmand
Seyedeh Bita Saadatmand
SHS.M. Hamidi
S.M. Hamidi
We propose a new Kretschmann configuration-based SPR biosensor using the combination of SrTiO3 (STO) and two-dimensional (2D) materials. Using STO and single-layer graphene (SLG) enhanced the sensitivity by about 187% compared to conventional SPR biosensors in the angle interrogation method. This enhancement is related to the 44 nm of silver/13 nm of STO/SLG structure with a sensitivity of 333.2 °/RIU and conventional Ag-based SPR biosensor has a sensitivity of 116 °/RIU. Although the highest achieved sensitivity is 409 °/RIU for the 40 nm of Ag/14 nm of STO but for biosensor applications, 2D materials are needed to act as a Biomolecule Recognition Element (BRE). Furthermore, numerical modeling of ellipsometry integrated with the SPR technique is used, and it showed extraordinary enhancement in the overall performance of the proposed biosensor. Firstly, using Ψ can help to enhance the quality factor (QF) of the 2D materials-based SPR biosensor by more than 50%. Furthermore, using differential phase from numerical modeling of ellipsometry, by providing the extraordinary sensitivity of about 32140 °/RIU, improve the sensitivity more than 270-fold compared to conventional Ag-based SPR biosensors. These results show that our proposed structure and method will be beneficial in biomedical applications.

28 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SSSeyedeh Bita Saadatmand
Seyedeh Bita Saadatmand
MCMohammad Javad Haji Najafi Chemerkouh
Mohammad Javad Haji Najafi Chemerkouh
VAVahid Ahmadi
Vahid Ahmadi
SHS.M. Hamidi
S.M. Hamidi
Using appropriate interlayers, the sensitivity and performance of conventional surface plasmon resonance (SPR) sensors can be improved in the Kretschmann configuration. In this paper, nano-layered SrTiO 3 is proposed as an interlayer, which besides protecting silver from oxidation, due to the high refractive index and zero loss in the visible region, increases field intensity and sensitivity. The use of Ti 3 C 2 T x MXene layer also leads to better adsorption of biomolecules due to high binding energies and large area. Using structural engineering, we optimized the physical parameters of the device. The theoretical results show that the proposed sensor has a sensitivity of 301.2°/RIU which is 164% higher than the Ag-only sensor, a detection accuracy of 0.119 Degree -1 , a quality factor of 35.84 RIU -1 , a detection range of 1.33-1.3377 and near-zero minimum reflectance for 43 nm Ag, 12 nm SrTiO 3 , and a monolayer of MXene. Therefore, the proposed sensor is promising to be used in diagnostic applications and portable biosensors. Although, we can reach the highest sensitivity and quality factor of 438.4°/RIU and 103.9 RIU -1 for 48 nm Ag and 13 nm SrTiO 3 without any MXene layer for non-bio (other) applications. However, using two-dimensional materials such as MXene, increases the adsorption efficiency of the biosensor. Furthermore, by using the reflectance intensity difference method, we reach the sensitivity of 8000%/RIU.

5 December 2022 in Journal of the Optical Society of America B
Verified
Journal Article
Closed access
SSSeyedeh Bita Saadatmand
Seyedeh Bita Saadatmand
MCMohammad Javad Haji Najafi Chemerkouh
Mohammad Javad Haji Najafi Chemerkouh
VAVahid Ahmadi
Vahid Ahmadi
SHS.M. Hamidi
S.M. Hamidi
Much effort is being made to improve the performance of the techniques currently used to detect biomolecules. One of the new fields that has attracted the attention of researchers is the use of graphene-based surface plasmon resonance (SPR), a real-time, label-free technique. In this field, there is still a need to introduce low-cost sensors that offer higher sensitivity. In this paper, to reduce the cost to fabricate the grating for phase matching, we use a low-cost 1D grating extracted from a digital video disc (DVD) without any lithography process. In addition, to improve the performance of the graphene-based SPR sensors after describing the plasmonic response, we use the surface plasmon enhanced by ellipsometry as a strong and sensitive characterization method. Using Ψ can help enhance the quality factor of the 2D materials-based SPR biosensor and the study of the delta parameter leads to a significant improvement in the sensitivity and minimum detectable concentration. The response of the delta parameter indicates that a slight change in miRNA-21 concentration, about 30 fM, leads to a sensitivity of 44.4 deg/100 fM, which is a significant change in the delta parameter. The results show that if appropriate complementary bioreceptors for the target’s biomolecules are used, the proposed sensor is attractive for use in biodetection and to measure a very small concentration of biomolecules.

18 March 2020 in Optical Materials Express
Verified
Journal Article
Closed access
MGMasih Ghasemi
Masih Ghasemi
NRN. Roostaei
N. Roostaei
FSF. Sohrabi
F. Sohrabi
SHS.M. Hamidi
S.M. Hamidi
PCP.K. Choudhury
P.K. Choudhury
Thin film grating meta-stadium nanocombs were fabricated and experimentally investigated for the purpose of glucose monitoring. The method of ellipsometry was used to study the sensitivity of the structure to the alterations in glucose concentration in aqueous solution. The existence of Tamm surface waves was demonstrated at the interface of two dielectric mediums (PDMS and SiO2) with acceptable resolution. The results revealed the best sensitivity achieved at a 48° angle of incidence over 350 − 450 nm visible wavelength span when the glucose concentration was varied in the range of 50 mg/l to 100 mg/l. Though the present work emphasizes on the monitoring of glucose, the structure can be used for sensing applications of other biological fluids as well.

29 May 2024 in ACS Omega
Verified
Journal Article
Open access
SSSeyedeh Bita Saadatmand
Seyedeh Bita Saadatmand
SSSamad Shokouhi
Samad Shokouhi
VAVahid Ahmadi
Vahid Ahmadi
SHS.M. Hamidi
S.M. Hamidi
In this study, we investigate the opto-electro-mechanical properties, thermodynamic stability, and moisture stability of the Ruddlesden-Popper (RP) two-dimensional perovskites of L2PbI4 (L = PEA, FPEA, BA, and BZA) using density functional theory. The goal is to explore their potential application in metastructures. The results show that the stability of FPEA2PbI4 is better than that of PEA2PbI4, BA2PbI4, and BZA2PbI4 due to the replacement of a hydrogen atom with a fluorine atom. On the other hand, BA2PbI4 is more flexible than other materials because it lacks an aromatic ring in its spacer cation, but it is less stable. We introduce a new kind of metastructure composed of an RP perovskite film and conduct an extensive investigation of the quasi-bound states in the continuum (q-BIC) characteristics by near-field analysis and multipole decomposition calculations. The q-BIC resonances in BZA2PBI4 have a greater quality factor due to its larger refractive index in comparison to other materials. Therefore, based on these results, the perovskite materials can be selected for the metastructures from different aspects of stability, flexibility, and refractive index.

7 February 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NRN. Roostaei
N. Roostaei
SHS.M. Hamidi
S.M. Hamidi
Color blindness, or color vision deficiency (CVD), is an ocular disease that suppresses the recognition of different colors. Recently, tinted glasses and lenses have been studied as hopeful devices for color blindness correction. In this study, 2D biocompatible and flexible plasmonic contact lenses were fabricated using polydimethylsiloxane (PDMS) and a low-cost, and simple design based on the soft nano-lithography method and investigated for correction of red–green (deuteranomaly) color blindness. In addition, the stability test of the fabricated plasmonic contact lenses was investigated into the phosphate buffered saline (PBS) solution and the proposed lens offers an excellent stability into the PBS solution. The plasmonic contact lens proposed herein is based on the plasmonic surface lattice resonance (SLR) phenomenon and offers a good color filter for color blindness correction. The biocompatibility, low cost, stability, and simple fabrication of these contact lenses can offer new insights for applications of color blindness correction.