Syazana Lim

Dr. Syazana Lim


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
SLSyazana Lim
Syazana Lim
MAMinhaz Uddin Ahmed
Minhaz Uddin Ahmed
In recent years, tremendous advances have been made in biosensors based on nanoscale electrochemical immunosensors for use in the fields of agriculture, food safety, biomedicine, quality control, and environmental and industrial monitoring.

1 June 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MRMohammad Rizwan
Mohammad Rizwan
SESyazwani Elma
Syazwani Elma
SLSyazana Lim
Syazana Lim
MAMinhaz Uddin Ahmed
Minhaz Uddin Ahmed

29 October 2014 in RSC Advances
Verified
Journal Article
Closed access
PDF file
SLSyazana Lim
Syazana Lim
HYHiroyuki Yoshikawa
Hiroyuki Yoshikawa
ETEiichi Tamiya
Eiichi Tamiya
HYHartini Mohd Yasin
Hartini Mohd Yasin
MAMinhaz Uddin Ahmed
Minhaz Uddin Ahmed
This study describes a highly sensitive electrochemical immunosensor for the detection of human chorionic gonadotropin (hCG) that uses gold nanoparticles (AuNP) as the electrochemical label and graphene as electrode material. The primary antibody was first immobilized on the graphene working electrode surface by physical adsorption. Antigen hCG was then added and sandwiched with a secondary antibody labelled with AuNPs. After this, a series of sandwich-type immunoreactions were performed on the electrode, AuNPs were quantified by subjecting the immunocomplex to a preoxidation process of high potential at 1.2 V for 40 s and immediately reduced and scanned by differential pulse voltammtery (DPV). Electrodeposition of gold during the reduction stage of the redox reaction was determined by cyclic voltammetry (CV) that showed a linear relationship with the different hCG concentrations. In this study, a linear relationship between reduction peak current signals and hCG concentration from 0 to 500 pg mL−1 (correlation coefficient of 0.97351) with a detection limit of 5 pg mL−1 was obtained.


22 April 2020 in Journal of Food Safety
Verified
Journal Article
Closed access
PDF file
AAAfiqah Nabihah Ahmad
Afiqah Nabihah Ahmad
SLSyazana Lim
Syazana Lim
NNNamasivayam Navaranjan
Namasivayam Navaranjan

1 August 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SLSyazana Lim
Syazana Lim
MAMinhaz Uddin Ahmed
Minhaz Uddin Ahmed