Tardu Özkartal

Dr. Tardu Özkartal

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TÖTardu Özkartal
Tardu Özkartal
ADandrea demarchi
andrea demarchi
MCMaria Luce Caputo
Maria Luce Caputo
EBEnrico Baldi
Enrico Baldi
GCGiulio Conte
Giulio Conte
AAAngelo Auricchio
Angelo Auricchio
With the demographic evolution of the population, patients undergoing surgery today are older and have an increasing number of sometimes complex comorbidities. Cardiac implantable electronic devices (CIED) are also getting more and more complex with very sophisticated programming algorithms. It may be generally assumed that magnet application reverts pacing to an asynchronous mode in pacemakers and disables tachycardia detection/therapy in internal cardioverter-defibrillators. However, depending on device type, manufacturer and model, the response to magnet application may differ substantially. For these reasons, perioperative management of CIED patients is getting more and more challenging. With this review article we provide an overview of optimal perioperative management of CIED patients with a detailed description of CIED response to magnet application depending on manufacturer and device-type, which may help in providing a safe perioperative management plan for the CIED patient.

19 January 2021 in Journal of the American Heart Association
Verified
Journal Article
Open access
PDF file
AAAngelo Auricchio
Angelo Auricchio
TÖTardu Özkartal
Tardu Özkartal
FSFrancesca Salghetti
Francesca Salghetti
LNLaura Neumann
Laura Neumann
SPSimone Pezzuto
Simone Pezzuto
GCGiulio Conte
Giulio Conte
Background: Short ECG P‐wave duration has recently been demonstrated to be associated with higher risk of atrial fibrillation (AF). The aim of this study was to assess the rate of AF recurrence after pulmonary vein isolation in patients with a short P wave, and to mechanistically elucidate the observation by computer modeling. Methods and Results: A total of 282 consecutive patients undergoing a first single‐pulmonary vein isolation procedure for paroxysmal or persistent AF were included. Computational models studied the effect of adenosine and sodium conductance on action potential duration and P‐wave duration (PWD). About 16% of the patients had a PWD of 110 ms or shorter (median PWD 126 ms, interquartile range, 115 ms–138 ms; range, 71 ms–180 ms). At Cox regression, PWD was significantly associated with AF recurrence ( P =0.012). Patients with a PWD <110 ms (hazard ratio [HR], 2.20; 95% CI, 1.24–3.88; P =0.007) and patients with a PWD ≥140 (HR, 1.87, 95% CI, 1.06–3.30; P =0.031) had a nearly 2‐fold increase in risk with respect to the other group. In the computational model, adenosine yielded a significant reduction of action potential duration 90 (52%) and PWD (7%). An increased sodium conductance (up to 200%) was robustly accompanied by an increase in conduction velocity (26%), a reduction in action potential duration 90 (28%), and PWD (22%). Conclusions: One out of 5 patients referred for pulmonary vein isolation has a short PWD which was associated with a higher rate of AF after the index procedure. Computer simulations suggest that shortening of atrial action potential duration leading to a faster atrial conduction may be the cause of this clinical observation.

17 September 2021 in EP Europace
Verified
Journal Article
Closed access
ADAndrea Demarchi
Andrea Demarchi
LNLaura Neumann
Laura Neumann
RRRoberto Rordorf
Roberto Rordorf
GCGiulio Conte
Giulio Conte
ASAntonio Sanzo
Antonio Sanzo
AAAngelo Auricchio
Angelo Auricchio
Aims: Data regarding the efficacy of catheter ablation in heart failure patients with severely dilated left atrium and reduced left ventricular ejection fraction (LVEF) are scanty. We sought to assess the efficacy of catheter ablation in patients with reduced LVEF and severe left atrial (LA) enlargement, and to compare it to those patients with preserved left ventricular function and equally dilated left atrium. Methods and results: Three patient groups with paroxysmal or persistent atrial fibrillation (AF) undergoing a first pulmonary vein isolation (PVI) were considered: Group 1 included patients with normal or mildly abnormal LA volume (≤41 mL/m2) and normal LVEF; Group 2 included patients with severe LA enlargement (>48 mL/m2) and normal LVEF; and Group 3 included patients with severe LA enlargement and reduced LVEF. Time to event analysis was used to investigate AF recurrences. The study cohort includes 439 patients; Group 3 had a higher prevalence of cardiovascular risk factors. LA enlargement was associated with a two-fold in risk of AF recurrence, on the contrary only a smaller non-significant increase of 30% was shown with the further addition of LVEF reduction. Conclusions: The long-term outcome of patients with severe LA dilatation and reduced LVEF is comparable to those with severe LA enlargement but preserved LVEF. Long-term efficacy of PVI is certainly affected by the enlargement of the left atrium, but less so by the addition of a reduced LVEF. CA remains the best strategy for rhythm control both in paroxysmal and persistent AF in this subgroup of patients.

10 November 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
AAAngelo Auricchio
Angelo Auricchio
ADAndrea Demarchi
Andrea Demarchi
TÖTardu Özkartal
Tardu Özkartal
DCDaniela Campanale
Daniela Campanale
MCMaria Luce Caputo
Maria Luce Caputo
GCGiulio Conte
Giulio Conte
To investigate the role of genetic testing in patients with idiopathic atrioventricular conduction disease requiring pacemaker (PM) implantation before the age of 50 years. All consecutive PM implantations in Southern Switzerland between 2010 and 2019 were evaluated. Inclusion criteria were: (i) age at the time of PM implantation: < 50 years; (ii) atrioventricular block (AVB) of unknown aetiology. Study population was investigated by ajmaline challenge and echocardiographic assessment over time. Genetic testing was performed using next-generation sequencing panel, containing 174 genes associated to inherited cardiac diseases, and Sanger sequencing confirmation of suspected variants with clinical implication. Of 2510 patients who underwent PM implantation, 15 (0.6%) were young adults (median age: 44 years, male predominance) presenting with advanced AVB of unknown origin. The average incidence of idiopathic AVB computed over the 2010–2019 time window was 0.7 per 100 000 persons per year (95% CI 0.4–1.2). Most of patients (67%) presented with specific genetic findings (pathogenic variant) or variants of uncertain significance (VUS). A pathogenic variant of PKP2 gene was found in one patient (6.7%) with no overt structural cardiac abnormalities. A VUS of TRPM4, MYBPC3, SCN5A, KCNE1, LMNA, GJA5 genes was found in other nine cases (60%). Of these, three unrelated patients (20%) presented the same heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene. Diagnostic re-assessment over time led to a diagnosis of Brugada syndrome and long-QT syndrome in two patients (13%). No cardiac events occurred during a median follow-up of 72 months. Idiopathic AVB in adults younger than 50 years is a very rare condition with an incidence of 0.7 per 100 000 persons/year. Systematic investigations, including genetic testing and ajmaline challenge, can lead to the achievement of a specific diagnosis in up to 20% of patients. Heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene was found in an additional 20% of unrelated patients, suggesting possible association of the variant with the disease.

1 November 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
GCGiulio Conte
Giulio Conte
KSKyoko Soejima
Kyoko Soejima
Carlo de AsmundisCarlo de Asmundis
Carlo de Asmundis
GCGian-Battista Chierchia
Gian-Battista Chierchia
MBMatteo Badini
Matteo Badini
AAAngelo Auricchio
Angelo Auricchio

28 March 2024 in European Heart Journal
Verified
Journal Article
Open access
PDF file
TÖTardu Özkartal
Tardu Özkartal
ADAndrea Demarchi
Andrea Demarchi
GCGiulio Conte
Giulio Conte
DPDamiano Pongan
Damiano Pongan
CKCatherine Marie Klersy
Catherine Marie Klersy
AAAngelo Auricchio
Angelo Auricchio
Bloodstream infection (BSI) of any cause may lead to device infection in cardiac implantable electronic device (CIED) patients. Aiming for a better understanding of the diagnostic approach, treatment, and outcome, patients with an implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy and defibrillator (CRT-D) hospitalized with BSI were investigated. This is a single-centre, retrospective, cohort analysis including consecutive ICD/CRT-D patients implanted between 2012 and 2021. These patients were screened against a list of all hospitalized patients having positive blood cultures consistent with diagnosed infection in any department of a local public hospital. The total cohort consisted of 515 patients. Over a median follow-up of 59 months (interquartile range 31–87 months), there were 47 BSI episodes in 36 patients. The majority of patients with BSI (92%) was admitted to non-cardiology units, and in 25 episodes (53%), no cardiac imaging was performed. Nearly all patients (85%) were treated with short-term antibiotics, whereas chronic antibiotic suppression therapy (n = 4) and system extraction (n = 3) were less frequent. Patients with BSI had a nearly seven-fold higher rate (hazard ratio 6.7, 95% confidence interval 3.9–11.2; P < .001) of all-cause mortality. Diagnostic workup of defibrillator patients with BSI admitted to a non-cardiology unit is often insufficient to characterize lead-related endocarditis. The high mortality rate in these patients with BSI may relate to underdiagnosis and consequently late/absence of system removal. Efforts to increase an interdisciplinary approach and greater use of cardiac imaging are necessary for timely diagnosis and adequate treatment. Mortality in patients with and without BSI. Blue line, patients without BSI; red line, patients with BSI. BSI, bloodstream infection; CI, confidence interval; CRT-D, cardiac resynchronization therapy and defibrillator; HR, hazard ratio; ICD, implantable cardioverter defibrillator.