Yue Zhou

Dr. Yue Zhou


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Rehabilitation and Assistive Technologies Engineering
Verified
Journal Article
Open access
PDF file
TDTyler Desplenter
Tyler Desplenter
YZYue Zhou
Yue Zhou
BEBrandon Pr Edmonds
Brandon Pr Edmonds
MLMyles Lidka
Myles Lidka
AGAllison Goldman
Allison Goldman
Ana Luisa TrejosAna Luisa Trejos
Ana Luisa Trejos
Recently, there has been a trend toward assistive mechatronic devices that are wearable. These devices provide the ability to assist without tethering the user to a specific location. However, there are characteristics of these devices that are limiting their ability to perform motion tasks and the adoption rate of these devices into clinical settings. The objective of this research is to perform a review of the existing wearable assistive devices that are used to assist with musculoskeletal and neurological disorders affecting the upper limb. A review of the existing literature was conducted on devices that are wearable, assistive, and mechatronic, and that provide motion assistance to the upper limb. Five areas were examined, including sensors, actuators, control techniques, computer systems, and intended applications. Fifty-three devices were reviewed that either assist with musculoskeletal disorders or suppress tremor. The general trends found in this review show a lack of requirements, device details, and standardization of reporting and evaluation. Two areas to accelerate the evolution of these devices were identified, including the standardization of research, clinical, and engineering details, and the promotion of multidisciplinary culture. Adoption of these devices into their intended application domains relies on the continued efforts of the community.

1 May 2017 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
YZYue Zhou
Yue Zhou
MNMichael D. Naish
Michael D. Naish
MJMary E. Jenkins
Mary E. Jenkins
Ana Luisa TrejosAna Luisa Trejos
Ana Luisa Trejos

25 July 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
YZYue Zhou
Yue Zhou
MJM. E. Jenkins
M. E. Jenkins
MNMichael Naish
Michael Naish
Ana Luisa TrejosAna Luisa Trejos
Ana Luisa Trejos
Recent progress in wearable technology has made wearable tremor suppression devices (WTSDs) for Parkinson's patients a potentially viable alternative solution for tremor management. So far, in contrast to wrist and elbow tremor, finger tremors have not been studied in depth despite the huge impact that they have on a patient's daily life. In addition, more evidence has been found showing that the performance of current tremor estimators may be limited by their model order due to the multiple harmonics present in tremor. The aim of this paper is to characterize finger and wrist tremor in both the time and frequency domains, and to propose a high-order tremor estimation algorithm. Tremor magnitudes are reported in the forms of linear acceleration, angular velocity, and angular displacement. The activation of forearm flexor and extensor muscles is also investigated. The frequency analysis shows that Parkinsonian tremors produce oscillations of the hand with pronounced harmonics. At last, a high-order weighted-frequency Fourier linear combiner (WFLC)-based Kalman filter is proposed. The percentage estimation accuracy achieved from the proposed estimator is 96.3 ± 1.7%, showing average improvements of 28.5% and 48.9% over its lower-order counterpart and the WFLC. The proposed estimator shows promise for use in a WTSD.

13 July 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
AIAnas Ibrahim
Anas Ibrahim
YZYue Zhou
Yue Zhou
MJMary E. Jenkins
Mary E. Jenkins
Ana Luisa TrejosAna Luisa Trejos
Ana Luisa Trejos
MNMichael Naish
Michael Naish
Wearable tremor suppression devices (WTSD) have been considered as a viable solution to manage parkinsonian tremor. WTSDs showed their ability to improve the quality of life of individuals suffering from parkinsonian tremor, by helping them to perform activities of daily living (ADL). Since parkinsonian tremor has been shown to be nonstationary, nonlinear, and stochastic in nature, the performance of the tremor models used by WTSDs is affected by their inability to adapt to the nonlinear behaviour of tremor. Another drawback that the models have is their limitation to estimate or predict one step ahead, which introduces delay when used in real time with WTSDs, which compromises performance. To address these issues, this work proposes a deep neural network model that learns the correlations and nonlinearities of tremor and voluntary motion, and is capable of multi-step prediction with minimal delay. A generalized model that is task and user-independent is presented. The model achieved an average estimation percentage accuracy of 99.2%. The average future voluntary motion prediction percentage accuracy with 10, 20, 50, and 100 steps ahead was 97.0%, 94.0%, 91.6%, and 89.9%, respectively, with prediction time as low as 1.5 ms for 100 steps ahead. The proposed model also achieved an average of 93.8% ± 1.5% in tremor reduction when it was tested in an experimental setup in real time. The tremor reduction showed an improvement of 25% over the Weighted Fourier Linear Combiner (WFLC), an estimator commonly used with WTSDs.

17 May 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YZYue Zhou
Yue Zhou
AIAnas Ibrahim
Anas Ibrahim
KHKenneth G. Hardy
Kenneth G. Hardy
MJMary E. Jenkins
Mary E. Jenkins
MNMichael Naish
Michael Naish
Ana Luisa TrejosAna Luisa Trejos
Ana Luisa Trejos
Objective: Approximately 25% of individualsliving with parkinsonian tremor do not respond to traditional treatments. Wearable tremor suppression devices (WTSD) provide an alternative approach, however, tremor in the fingers has not been given as much attention as tremor in the elbow and the wrist. Therefore, the objective of this study is to design a wearable tremor suppression glove that can suppress tremor simultaneously, but independently, in multiple hand joints without restricting the user's voluntary motion. Methods: A WTSD was designed for managing tremor in the index finger metacarpophalangeal (MCP) joint, thumb MCP joint, and the wrist. The prototype was tested and assessed on a participant living with parkinsonian tremor. Results: The experimental evaluation showed an overall suppression of 73.1%, 80.7%, and 85.5% in resting tremor, 70.2%, 79.5%, and 81% in postural tremor, and 60.0%, 58.7%, and 65.0% in kinetic tremor in the index finger MCP joint, the thumb MCP joint, and the wrist, respectively. Conclusion: This first assessment of a WTSD for people living with Parkinson's disease provides confirmation of the feasibility of the approach. The next step requires a comprehensive validation on a broader population in order to evaluate the performance of the WTSD. Significance: This study demonstrates the feasibility of using a WTSD to manage hand and finger tremor. The device enriches the field of upper-limb tremor management, as the first WTSD for multiple joints of the hand.

27 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
GFGhazal Farhani
Ghazal Farhani
YZYue Zhou
Yue Zhou
MJMary E. Jenkins
Mary E. Jenkins
MNMichael Naish
Michael Naish
Ana Luisa TrejosAna Luisa Trejos
Ana Luisa Trejos
Hand tremor is one of the dominating symptoms of Parkinson’s disease (PD), which significantly limits activities of daily living. Along with medications, wearable devices have been proposed to suppress tremor. However, suppressing tremor without interfering with voluntary motion remains challenging and improvements are needed. The main goal of this work was to design algorithms for the automatic identification of the tremor type and voluntary motions, using only surface electromyography (sEMG) data. Towards this goal, a bidirectional long short-term memory (BiLSTM) algorithm was implemented that uses sEMG data to identify the motion and tremor type of people living with PD when performing a task. Moreover, in order to automate the training process, hyperparamter selection was performed using a regularized evolutionary algorithm. The results show that the accuracy of task classification among 15 people living with PD was 84±8%, and the accuracy of tremor classification was 88±5%. Both models performed significantly above chance levels (20% and 33% for task and tremor classification, respectively). Thus, it was concluded that the trained models, based on using purely sEMG signals, could successfully identify the task and tremor types.