Brad Fossum

Mr. Brad Fossum

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2022 in Medicina
Verified
Journal Article
Open access
PDF file
ABAlex W. Brady
Alex W. Brady
JTJakub Tatka
Jakub Tatka
LFLorenzo Fagotti
Lorenzo Fagotti
BKBryson R. Kemler
Bryson R. Kemler
BFBrad Fossum
Brad Fossum
Background and Objectives: Intraoperative fluoroscopy can be used to increase the accuracy of the acetabular component positioning during total hip arthroplasty. However, given the three-dimensional nature of cup positioning, it can be difficult to accurately assess inclination and anteversion angles based on two-dimensional imaging. The purpose of this study is to validate a novel method for calculating the 3D orientation of the acetabular cup from 2D fluoroscopic imaging. Materials and Methods: An acetabular cup was implanted into a radio-opaque pelvis model in nine positions sequentially, and the inclination and anteversion angles were collected in each position using two methods: (1) a coordinate measurement machine (CMM) was used to establish a digitalized anatomical coordinate frame based on pelvic landmarks of the cadaveric specimen, and the 3D position of the cup was then expressed with respect to the anatomical planes; (2) AP radiographic images were collected, and a mathematical formula was utilized to calculate the 3D inclination and anteversion based on the 2D images. The results of each method were compared, and interrater and intrarater reliably of the 2D method were calculated. Results: Interrater reliability was excellent, with an interclass correlation coefficient (ICC) of 0.988 (95% CI 0.975–0.994) for anteversion and 0.997 (95% CI 0.991–0.999) for inclination, as was intrarater reliability, with an ICC of 0.995 (95% CI 0.985–0.998) for anteversion and 0.998 (95% CI 0.994–0.999) for inclination. Intermethod accuracy was excellent with an ICC of 0.986 (95% CI: 0.972–0.993) for anteversion and 0.993 (95% CI: 0.989–0.995) for inclination. The Bland–Altman limit of agreement, which represents the error between the 2D and 3D methods, was found to range between 2 to 5 degrees. Conclusions: This data validates the proposed methodology to calculate 3D anteversion and inclination angles based on 2D fluoroscopic images to within five degrees. This method can be utilized to improve acetabular component placing intraoperatively and to check component placement postoperatively.

29 June 2022 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
FPFletcher R. Preuss
Fletcher R. Preuss
BFBrad Fossum
Brad Fossum
APAnnalise M. Peebles
Annalise M. Peebles
SEStephanie K. Eble
Stephanie K. Eble
MPMatthew T. Provencher
Matthew T. Provencher
There is no consensus on whether to repair the subscapularis in the setting of reverse total shoulder arthroplasty (rTSA). There have been an assortment of studies showing mixed results regarding shoulder stability and postoperative strength outcomes when looking at subscapularis repair in rTSA. The purpose of this systematic review was to investigate differences in biomechanical strength outcomes of cadaveric subscapularis repair vs. no repair in rTSA.Increased force will be required to move the shoulder through normal range of motion (ROM) in cadaveric rTSA shoulders with the subscapularis repaired when compared with no subscapularis repair. A comprehensive literature review was conducted in accordance with the 2009 Preferred Reporting Items for Systematic Review and Meta-Analysis statement. The databases used to search the keywords used for the concepts of subscapularis, reverse total shoulder arthroplasty, and muscle strength were PubMed (includes MEDLINE), Embase, Web of Science, Cochrane Reviews and Trials, and Scopus. Original, English-language cadaveric studies evaluating rTSA and subscapularis management were included, with subscapularis repair surgical techniques and strength outcomes being evaluated for each article meeting inclusion criteria. The search yielded 4113 articles that were screened for inclusion criteria by 4 authors. Two articles met inclusion criteria and were subsequently included in the final full-text review. A total of 11 shoulders were represented between these 2 studies. Heterogeneity of the data across the 2 studies did not allow for meta-analysis. Hansen et al found that repair of the subscapularis with rTSA significantly increased the mean joint reaction force and the force required by the posterior deltoid, total deltoid, infraspinatus, teres minor, total posterior rotator cuff, and pectoralis major muscles. Giles et al found that rotator cuff repair and glenosphere lateralization both increased total joint load. The present review of biomechanical literature shows that repair of the subscapularis in the setting of rTSA can effectively restore shoulder strength by increasing joint reactive forces and ROM force requirements of other rotator cuff muscles and of the deltoid muscle. Available biomechanical evidence is limited, and further biomechanical studies evaluating the strength of various subscapularis repair techniques are needed to evaluate the effects of these techniques on joint reactive forces and muscle forces required for ROM.

1 January 2024 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
PBPongpak Bhumiwat
Pongpak Bhumiwat
BFBrad Fossum
Brad Fossum
RHRony-Orijit Dey Hazra
Rony-Orijit Dey Hazra
PGPhob Ganokroj
Phob Ganokroj
Inferior pole fractures of the patella are a type of patellar fracture that has various complexities. Most current techniques are associated with hardware-related complications, which is one of the main concerns when treating this complex fracture. We present a new technique that does not require metal implant removal, causes little to no irritation of the quadriceps muscle, and provides strong fixation that allows for early range of motion postoperatively.

2 July 2025 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
BFBrad Fossum
Brad Fossum
MBMichael D. Baird
Michael D. Baird
DYDaniel Z. You
Daniel Z. You
JSJohn W. Sperling
John W. Sperling

27 July 2026 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
DYDaniel Z. You
Daniel Z. You
SRSamuel S. Rudisill
Samuel S. Rudisill
BFBrad Fossum
Brad Fossum
MBMichael D. Baird
Michael D. Baird
SDShawn W. O’ Driscoll
Shawn W. O’ Driscoll
MMMark E. Morrey
Mark E. Morrey

1 June 2026 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
SRSamuel S. Rudisill
Samuel S. Rudisill
DYDaniel Z. You
Daniel Z. You
BFBrad Fossum
Brad Fossum
SOShawn W. O'DRiscoll
Shawn W. O'DRiscoll
JSJoaquin Sanchez-Sotelo
Joaquin Sanchez-Sotelo
MMMark E. Morrey
Mark E. Morrey