In this paper, based on the composite laminated plate theory and a strain energy model, the damping capacity of a Carbon Fiber Reinforced Plastics (CFRP) raft frame was studied. According to the finite element analysis (FEA) and damping ratio prediction model, the influences of different layups on the damping capacity of the raft frame and its components (top/bottom plate and I-support) were discussed. Comparing the FEA results with the test results, it can be figured out that the CFRP laminate layup has a great influence on the damping ratio of the raft frame, and the maximum error of the first-order natural frequency and damping ratio of the top/bottom plate were 5.6% and 15.1%, respectively. The maximum error of the first-order natural frequency of the I-support between the FEA result and the test result was 7.5%, suggesting that because of the stress concentration, the error of the damping ratio was relatively large. As for the raft frame, the damping performance was affected by the I-support arrangement and the simulation analysis was in good agreement with the experimental results. This study can provide a useful reference for improving the damping performance of CFRP raft frames.
19 October 2023 in IEEE Transactions on Instrumentation and Measurement
The flow maldistribution inside plate-fin heat exchangers is a decisive factor leading to the deterioration of heat transfer performance. This paper proposes the configurations of flat and curved baffles with different holes to optimize flow distribution. The invasive method using fiber Bragg grating (FBG)sensors for monitoring the local flow velocity in heat exchangers is first proposed. Multiple FBG sensors are embedded in the plate-fin core to measure the flow velocity of each channel. The effectiveness in balancing the flow velocity of flat and curved baffle configurations is compared against a header configuration without a baffle. The results indicate that adding a baffle, whether it is flat or curved, is profitable to facilitate the flow field inside the plate-fin core. Compared with no baffle configuration, the flat and curved baffle configurations achieve a decrease rate of 61% and 66% in the sum flow nonuniformity of heat exchangers. The standard deviation has been reduced by 60% and 80%, respectively. The energy loss caused by the curved plate configuration is relatively low. The embedded FBG sensors address real-time monitoring of local flow velocity in the plate-fin heat exchanger. The ameliorative baffle structure in the header and FBG sensing technology provide ideas for optimizing and monitoring the internal flow field inside plate-fin heat exchangers.
3 March 2025 in IEEE Transactions on Instrumentation and Measurement
A novel non-invasive real-time monitoring heat flux measurement with only one measuring point based on tapered metallized fiber Bragg grating (T-MFBG) has been proposed in this paper. The preparation of T-MFBG involves magnetron sputtering of the first metal layer Ti and electroplating of the second metal layer Ni. The axially increased diameter of T-MFBG broadens the spectrum with the increase of heat flux. The heat flux sensing theoretical model and working principle of T-MFBG are established to analyze the sensing characteristics of T-MFBG. Numerical analysis and theoretical calculation show that the full width at half maximum (FWHM) of T-MFBG with a length of 10 mm and a diameter of 500-550 μm increases linearly with the heat flux, and the stable transformation of heat flux and FWHM can be realized. A heat flux calibration platform was built and its feasibility was verified by simulation. The outlet pipe section heat flux of the piston pump in the hydraulic system was quantitatively measured by the T-MFBG heat flux measurement method. When monitoring the heat flux of stainless steel, the sensitivity of T-MFBG is 0.0025 pm / (W/ m2). The measurement range is 0-6795 W/ m2. The heat flux measurement method based on T-MFBG with a length of 1 cm and a maximum diameter of 1 mm has the advantages of heat flux-FWHM linear conversion, single point, real-time, small installation space, and non-invasive. It can provide theoretical guidance for the design of fiber grating heat flux sensor and facilitate the design of a series of sensors for specific measurement requirements.
In modern aerospace cockpits, the display and control console (DCC) serves as a critical human–machine interface. Light weight is particularly important in this industry, especially for key equipment such as the DCC. To address the excessive weight of aluminum alloy DCCs while achieving desirable mechanical properties and vibration-damping performance, this study developed a Carbon Fiber Reinforced Polymer (CFRP) DCC; its superior performance was verified through finite element analysis (FEA) and a vibration test. Compared with conventional aluminum alloy structures, the newly designed DCC achieves approximately a 40% weight reduction while meeting all rigidity, strength, and vibration requirements. This study successfully demonstrates the feasibility of using CFRP to replace aluminum alloy in aircraft DCC and provides a systematic design methodology for similar structures.