Kirk Shelley

Dr. Kirk Shelley


Research Focus & Metrics

Academic Career Length

47Years (1980-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2007 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
KSKirk Shelley
Kirk Shelley
In this article, I examine the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis. The PPG waveform was first described in the 1930s. Although considered an interesting ancillary monitor, the “pulse waveform” never underwent intensive investigation. Its importance in clinical medicine was greatly increased with the introduction of the pulse oximeter into routine clinical care in the 1980s. Its waveform is now commonly displayed in the clinical setting. Active research efforts are beginning to demonstrate a utility beyond oxygen saturation and heart rate determination. Future trends are being heavily influenced by modern digital signal processing, which is allowing a re-examination of this ubiquitous waveform. Key to unlocking the potential of this waveform is an unfettered access to the raw signal, combined with standardization of its presentation, and methods of analysis. In the long run, we need to learn how to consistently quantify the characteristics of the PPG in such a way as to allow the results from research efforts be translated into clinically useful devices.

7 November 2007 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
SLSheng Lu
Sheng Lu
HZHe Zhao
He Zhao
KJKihwan Ju
Kihwan Ju
KSKunson Shin
Kunson Shin
MLMyoungho Lee
Myoungho Lee
KCKi H. Chon
Ki H. Chon

1 December 2014 in Best Practice & Research Clinical Anaesthesiology
Verified
Journal Article
Closed access
AAAymen Alian
Aymen Alian
KSKirk Shelley
Kirk Shelley

17 October 2007 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
AAAymen Alian
Aymen Alian
AHAla S. Haddadin
Ala S. Haddadin
HTHossam Tantawy
Hossam Tantawy
TBTarek M. Badr
Tarek M. Badr
RSRobert G. Stout
Robert G. Stout
KSKirk Shelley
Kirk Shelley

1 June 2001 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
AAAymen A. Awad
Aymen A. Awad
MGM. Ashraf M. Ghobashy
M. Ashraf M. Ghobashy
WOWagih Ouda
Wagih Ouda
RSRobert G. Stout
Robert G. Stout
DSDavid G. Silverman
David G. Silverman
KSKirk Shelley
Kirk Shelley
The cold pressor test is often used to assess vasoconstrictive responses because it simulates the vasoconstrictive challenges commonly encountered in the clinical setting. With IRB approval, 12 healthy volunteers, aged 25–50 yr, underwent baseline plethysmographic monitoring on the finger and ear. The contralateral hand was immersed in ice water for 30 s to elicit a systemic vasoconstrictive response while the recordings were continued. The changes in plethysmographic amplitude for the first 30 s of ice water immersion (period of maximum response) of the finger and ear were compared. The data indicate a significant disparity between the finger and the ear signals in response to the cold stimulus. The average finger plethysmographic amplitude measurement decreased by 48% ± 19%. In contrast, no significant change was seen in the ear plethysmographic amplitude measurement, which decreased by 2% ± 10%. We conclude that the ear is relatively immune to the vasoconstrictive effects. These findings suggest that the comparison of the ear and finger pulse oximeter wave forms might be used as a real-time monitor of sympathetic tone and that the ear plethysmography may be a suitable monitor of the systemic circulation.

1 August 2011
Verified
Conference Paper
Closed access
NSNandakumar Selvaraj
Nandakumar Selvaraj
YMYitzhak Mendelson
Yitzhak Mendelson
KSKirk Shelley
Kirk Shelley
DSDavid G. Silverman
David G. Silverman
KCK. H. Chon
K. H. Chon
Motion and noise artifacts (MNA) have been a serious obstacle in realizing the potential of Photoplethysmogram (PPG) signals for real-time monitoring of vital signs. We present a statistical approach based on the computation of kurtosis and Shannon Entropy (SE) for the accurate detection of MNA in PPG data. The MNA detection algorithm was verified on multi-site PPG data collected from both laboratory and clinical settings. The accuracy of the fusion of kurtosis and SE metrics for the artifact detection was 99.0%, 94.8% and 93.3% in simultaneously recorded ear, finger and forehead PPGs obtained in a clinical setting, respectively. For laboratory PPG data recorded from a finger with contrived artifacts, the accuracy was 88.8%. It was identified that the measurements from the forehead PPG sensor contained the most artifacts followed by finger and ear. The proposed MNA algorithm can be implemented in real-time as the computation time was 0.14 seconds using Matlab®.