Spin defects in solid-state materials are strong candidate systems for quantum information technology and sensing applications. Here we explore in details the recently discovered negatively charged boron vacancies (VB−) in hexagonal boron nitride (hBN) and demonstrate their use as atomic scale sensors for temperature, magnetic fields and externally applied pressure. These applications are possible due to the high-spin triplet ground state and bright spin-dependent photoluminescence of the VB−. Specifically, we find that the frequency shift in optically detected magnetic resonance measurements is not only sensitive to static magnetic fields, but also to temperature and pressure changes which we relate to crystal lattice parameters. We show that spin-rich hBN films are potentially applicable as intrinsic sensors in heterostructures made of functionalized 2D materials.
Transparent crystalline scintillators such as cerium-doped YAG or LuAG are widely used in X-ray imaging for the indirect detection of X-rays. The application of reflective coatings on the front side to improve the optical gain is common practice for flat panel detectors with CsI or Gd2O2S powder scintillators but still largely unknown for crystalline scintillators such as LuAG. This work shows experimentally and quantitatively how a black and reflective coating on the X-ray side of a 2 mm LuAG:Ce scintillator improves the image quality compared to a 2 mm LuAG:Ce scintillator without a coating. The measurements have been done for two different distances, with 2 m and 29.7 m on the BM18 beamline of the European Synchrotron. The Modulation Transfer Function (MTF) and the Signal-to-Noise-Ratio (SNR2) power spectrum as well as contrast-to-noise ratio are used for comparing image quality. Propagation-based phase contrast strongly enhances the SNR2 amplitudes (gain ≈10 from 2 m to 29.7 m object-detector distance) of the raw images’ spectrum independent of the scintillator coating. For both detector positions, the reflective coating is able to raise SNR2 by up to 80% through the improved optical gain, while black coating does the opposite (decrease SNR2 by 20%) with respect to no coating. With the tested optical setups, changes in MTF /sharpness between the coatings are minor. Comparing CNR2 in CT scans of a multi-material sample, in this case an electric motor, we observe the reflective coating yielding better material contrast for plastic and air. Application and effect of Wiener-deconvolution, along with Paganin-type phase retrieval, are also discussed in the context of CT image quality.
Holotomography is an extension of computed tomography where samples with low X-ray absorption can be investigated with higher contrast. In order to achieve this, the imaging system must yield an optical resolution of a few micrometers or less, which reduces the measurement area (field of view = FOV) to a few mm at most. If the sample size, however, exceeds the field of view (called local tomography or region of interest = ROI CT), filter problems arise during the CT reconstruction and phase retrieval in holotomography. In this paper, we will first investigate the practical impact of these filter problems and discuss approximate solutions. Secondly, we will investigate the effectiveness of a technique we call “multiscalar holotomography”, where, in addition to the ROI CT, a lower resolution non-ROI CT measurement is recorded. This is used to avoid the filter problems while simultaneously reconstructing a larger part of the sample, albeit with a lower resolution in the additional area.
Scattered light makes up a significant amount of recorded intensities during tomographic imaging, thereby leading to severe misinterpretation and artifacts in the reconstructed volume images. Correcting artificial intensities that stem from scattered light, therefore, is of primary interest and demands quantitative measurements. While numerous methods have been developed to reduce X-ray scattering artifacts, fewer methods deal with optical scattering. In this study, a measurement method for determining optical scattering in scintillators is presented with the aim of further developing correction algorithms. A theoretical model based on internal multiple reflections was developed for this purpose. This model assumes an additive exponential kernel with a certain scattering length to the system’s point spread function. This assumption was confirmed, and the scatter length was estimated from three new different kinds of experiments (hgap, rect, and LSF) on the BM18 beamline of the European synchrotron. The experiments further revealed significant differences in scattering proportion and length when different coatings are applied to the front and back faces of crystalline LuAG scintillators. Anti-reflective coatings on the backside show an effect of reducing the scattering magnitude while reflective coatings on the front side increase the proportion of the unscattered signal and, thus, show proportionally less scattering than black coating or no front coating. In particular, roughened black coating is found to worsen optical scattering. In summary, our results indicate that a combination of reflective (front) and anti-reflective (back) coatings yields the least optical scattering and, hence, the best image quality.
Optimizing phase-contrast micro-computed tomography (µCT) for a given object is not trivial if the radiation is polychromatic and the object multi-material. This study demonstrates how an optimal combination of propagation distance and mean energy (set by attenuation filters) may be derived for such an object (an electromotor scanned on beamline BM18 at ESRF in Grenoble, France). In addition to appropriate image quality metrics, it is mandatory to define a task. In that respect, raising Emean from 100 keV to 164 keV mitigates beam hardening by metal parts, yet raising Emean further to 230 keV deteriorates CNR2 (where CNR is contrast-to-noise ratio) due to higher image noise. Propagation distances between d = 2 m and 25.3 m are evaluated crosswise with energy. While longer propagation distances generally yield higher CNR2, shorter distances appear favorable when discerning plastic near metal parts. SNR2 (where SNR is signal-to-noise ratio) power spectra and modulation transfer (MTF) are evaluated independently from two-dimensional projections supporting volume image analysis for which image sharpness depends strongly on the digital filters (Paganin and Wiener) which are applied along with filtered back-projection. In summary, optimizing synchrotron µCT scans remains a very complex task which differs from object to object. A physically accurate model of the complete imaging process may not only allow for optimization by simulation but also ideally improve CT image reconstruction in the near future.