Luis Felipe Contreras Vásquez

Dr. Luis Felipe Contreras Vásquez

Technical University of Ambato
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
LVLuis Felipe Contreras Vásquez
Luis Felipe Contreras Vásquez
YLYinzhe Liu
Yinzhe Liu
CPChristos Paterakis
Christos Paterakis
DRDaniel Reed
Daniel Reed
DBDavid Book
David Book

1 August 2017 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
YLYinzhe Liu
Yinzhe Liu
DRDaniel Reed
Daniel Reed
CPChristos Paterakis
Christos Paterakis
LVLuis Felipe Contreras Vásquez
Luis Felipe Contreras Vásquez
MBMarcello Baricco
Marcello Baricco
DBDavid Book
David Book

22 January 2022 in Metals
Verified
Journal Article
Open access
PDF file
LVLuis Felipe Contreras Vásquez
Luis Felipe Contreras Vásquez
CRCelia MARGARITA Mayacela Rojas
Celia MARGARITA Mayacela Rojas
ABAlberto Bustillos
Alberto Bustillos
Leonardo RenterìaLeonardo Renterìa
Leonardo Renterìa
DBDavid Book
David Book
The formation and hydrogen sorption properties of the NaMgH3 perovskite/type hydride have been examined. Samples were mechanically ball milled under argon for 2, 5 and 15 h; then characterized by X-ray diffraction (XRD), differential scanning calorimetry (DSC), and thermogravimetric analysis (TGA) coupled with a mass spectrometer (MS). Lattice parameters and cell volume of the main NaMgH3 phase increase as a function of milling. Dehydrogenation proceeded in two-step reactions for the NaMgH3. The maximum amount of released hydrogen was achieved for the 2 h milled NaMgH3 hydride accounting for 5.8 wt.% of H2 from 287 °C to 408 °C. Decomposed NaMgH3 samples were reversibly hydrogenated under 10 bar H2 at ~200 °C.

1 August 2018 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
YLYinzhe Liu
Yinzhe Liu
Michael HeereMichael Heere
Michael Heere
LVLuis Felipe Contreras Vásquez
Luis Felipe Contreras Vásquez
CPChristos Paterakis
Christos Paterakis
MSMagnus H. Sørby
Magnus H. Sørby
DBDavid Book
David Book

1 August 2017 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
CPChristos Paterakis
Christos Paterakis
SGSheng Guo
Sheng Guo
Michael HeereMichael Heere
Michael Heere
YLYinzhe Liu
Yinzhe Liu
LVLuis Felipe Contreras Vásquez
Luis Felipe Contreras Vásquez
DBDavid Book
David Book

17 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
WRWladimir Josè Ramírez
Wladimir Josè Ramírez
CRCelia MARGARITA Mayacela Rojas
Celia MARGARITA Mayacela Rojas
LVLuis Felipe Contreras Vásquez
Luis Felipe Contreras Vásquez
MMMicaela Shambi Minda
Micaela Shambi Minda
FRFrancisco Ramírez
Francisco Ramírez
JCJonatan Chacón
Jonatan Chacón
Permeable concrete is a material that allows water filtration, reduces surface runoff, and maintains the natural water cycle. Previous studies have shown that its mechanical properties, particularly its compressive and flexural tensile strengths, are generally lower than those of conventional concrete, with significant variability observed among similar tests. This study investigates the compressive strength, flexural strength, and permeability of polypropylene fiber-reinforced permeable concrete specimens at two water–cement ratios (0.30 and 0.35). The mix design was conducted using the ACI 522R-10 method. Forty-eight cylinders measuring 200 mm × 100 mm were fabricated for permeability and compression tests. Additionally, 12 beams measuring 100 mm × 100 mm × 350 mm were produced and subjected to simple flexural testing in accordance with ASTM C78 guidelines. Compressive strength versus permeability and load versus deflection graphs were plotted, and the fracture energy was calculated for various deflections. The results indicate that the addition of fibers increased permeability and tensile strength but decreased compressive strength. Furthermore, an increase in the water–cement ratio led to higher compressive and flexural tensile strengths.