Seyed Amir Hosseini

Dr. Seyed Amir Hosseini

Electrical and Computer Engineering Group, Golpayegan College of Engineering, Isfahan University of Technology, Golpayegan, Iran
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ASAlireza Sistani
Alireza Sistani
SHSeyed Amir Hosseini
Seyed Amir Hosseini
VSVahideh Sadat Sadeghi
Vahideh Sadat Sadeghi
BTBehrooz Taheri
Behrooz Taheri
Variations in fault currents, short times to clear the fault, and a lack of a natural current zero-crossing point are the most important challenges that DC microgrid protection faces. This challenge becomes more complicated with the presence of electric vehicles and energy storage systems due to their uncertainties. For this reason, in this paper, a new method for fault detection in DC microgrids with the presence of electric vehicles and energy storage systems is proposed. The new proposed method uses the combination of dynamic mode decomposition and instantaneous frequency for fault detection. In this method, first, a reference signal is made using the voltage and current signal sampled from the DC microgrid using the dynamic mode decomposition method. Next, in order to detect the fault, the instantaneous frequency value of the reference signal is calculated by the Hilbert transform. The simultaneous use of voltage and current signals reduces the transient effects of the control system on the proposed protection method. In order to measure voltage and current signals, only one intelligent electronic device unit is used in this paper. The proposed new method has been tested on a single-bus DC microgrid with the presence of electric vehicles and energy storage systems in MATLAB 2019b software. The results show that this method can detect all types of faults in DC microgrids, electric vehicles, and photovoltaics. Also, this method is immune to the uncertainties of the generation of distributed generation resources and the existence of noise distortions in the measured signals.

17 December 2022 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
BTBehrooz Taheri
Behrooz Taheri
SHSeyed Amir Hosseini
Seyed Amir Hosseini
SSSirus Salehimehr
Sirus Salehimehr
Nowadays, due to the simplicity of operation and proper coordination characteristics, distance relays are being extensively used in the protection of power transmission lines. Despite many advantages, the distance relay is exposed to a maloperation when a power swing phenomenon occurs. Power swings may occur due to major disturbances, such as switching lines, generator interruptions, and connecting or disconnecting a large part of the loads, causing outages in healthy lines. Detecting power swing and preventing distance relay maloperation has always been a challenge. In addition, different parameters can have a great impact on the performance of power swing detection methods. In this paper, these parameters and their effects are examined along with various methods for detecting power swings. Accordingly, this comprehensive review covers all aspects of power swing phenomenon and its detection, including causes of power swings, power swing detection methods, determining threshold values in power swing methods, effecting of compensated lines and wind farms in power swing detection methods, and testing power swing function in the distance relays. It is hoped that this study will be helpful for researchers in power system protection to find relevant references and develop new methods for power swing function.

29 June 2023 in Electric Power Systems Research
Verified
Journal Article
Closed access
ANAli Akbar Nazari
Ali Akbar Nazari
SHSeyed Amir Hosseini
Seyed Amir Hosseini
BTBehrooz Taheri
Behrooz Taheri

12 February 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
BTBehrooz Taheri
Behrooz Taheri
SHSeyed Amir Hosseini
Seyed Amir Hosseini
HHHamed Hashemi-Dezaki
Hamed Hashemi-Dezaki
This paper introduces an innovative method for the intelligent protection of AC microgrids that incorporate renewable energy sources and electric vehicle charging stations. To extract relevant features, current signals from both sides of the distribution line are sampled. Subsequently, the differential current is calculated, and the resultant signals are processed using Compressed Sensing Theory and Variational Mode Decomposition to extract key features. These extracted features serve as input data for training the proposed wide and deep learning model. The proposed method was evaluated on a microgrid that incorporated electric vehicle chargers and wind turbines. The results indicate that this approach can effectively identify and categorize different types of faults in AC microgrids. Moreover, it demonstrates stable and dependable performance in the face of typical transients, and its accuracy is not influenced by uncertainties in the microgrid topology.

20 November 2024 in e-Prime - Advances in Electrical Engineering, Electronics and Energy
Verified
Journal Article
Open access
SHSeyed Amir Hosseini
Seyed Amir Hosseini
BTBehrooz Taheri
Behrooz Taheri
SSSeyed Hossein Hesamedin Sadeghi
Seyed Hossein Hesamedin Sadeghi
ANAdel Nasiri
Adel Nasiri

1 January 2025 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
BTBehrooz Taheri
Behrooz Taheri
SHSeyed Amir Hosseini
Seyed Amir Hosseini
This paper presents a new statistical approach for reliably detecting power swings and faults in transmission lines that include grid‐following (GFL) inverters. The method combines the strengths of the cumulative sum control chart (CUSUM) and entropy analysis (EA), using CUSUM's ability to quickly pick up on signal changes and EA's insight into system complexity. To test the proposed method, simulations were carried out in PSCAD/MATLAB on a modified IEEE 14‐bus system with a GFL‐type inverter‐based resource. The results show that the method can effectively detect both faults and power swings, even in the presence of additive white Gaussian noise (signal‐to‐noise ratio = 10 dB). It also accurately distinguishes between different transient events, such as load switching, generator trips, and capacitor bank switching, with a 100% success rate in identifying non‐fault conditions. Furthermore, it consistently detects faults across a range of fault resistances (0 to 10 Ω) with perfect accuracy. Compared to existing techniques, this approach performs better in systems that integrate GFL inverters and offers a more efficient solution with lower computational requirements for power system protection.