Francesca Toto

Dr. Francesca Toto

Cardiocentro Ticino Institute, 6900, Lugano
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FTFrancesca Toto
Francesca Toto
TTTiziano Torre
Tiziano Torre
LTLucia Turchetto
Lucia Turchetto
VCViviana Lo Cicero
Viviana Lo Cicero
SSSabrina Soncin
Sabrina Soncin
Enrico FerrariEnrico Ferrari
Enrico Ferrari
(1) Introduction: Intraoperative preservation solutions for saphenous vein grafts may influence the endothelial structure and increase the risk of graft failure after coronary surgery. The aim of the study was to compare the efficacy of three solutions in maintaining the endothelial cell integrity of venous segments. (2) Methods: We tested the efficacy of physiological saline solution (PSS), heparinized autologous blood (HAB) and DuraGraft® in preserving the endothelium of vein segments by evaluating the degree of endothelial cell apoptosis. Two incubation times (2 and 4 h from harvesting) were used for each solution. The quantification of apoptotic cells was computed as the intensity nuclei/intensity area ratio. (3) Results: After 2 h of ischemia, the degree of apoptosis decreased progressively across the use of DuraGraft, HAB and PSS (p = 0.004), although only the difference between DuraGraft and PSS yielded a statistical significance (p = 0.002). After 4 h, a similar decrease in apoptosis was shown across the three media; however, statistical significance was not reached. The analysis of the elapsed time (2 or 4 h of incubation) showed that this was a relevant factor in maintaining the endothelial structural integrity independently from the storage solution (test for interaction of media and time p = 0.010). (4) Conclusion: Within 2 h of incubation, endothelial structural integrity depended on the incubating medium. DuraGraft better protected the SVG against ischemic-induced apoptosis when compared to saline solution. Prolonged ischemia was associated with extended endothelium damage and none of the studied solutions protected the vein graft.

20 March 2024 in Asian Cardiovascular and Thoracic Annals
Verified
Journal Article
Closed access
TTTiziano Torre
Tiziano Torre
HSHervé Schlotterbeck
Hervé Schlotterbeck
FFFrancesco Ferraro
Francesco Ferraro
CKCatherine Klersy
Catherine Klersy
GSGiuseppina Surace
Giuseppina Surace
SDStefanos Demertzis
Stefanos Demertzis
Background: Blood glucose level variability has been associated with increased risk of complication in the postoperative setting of cardiovascular surgery. Although interesting for optimization of blood glucose management in this context, continuous blood glucose (CBG) devices can have a limited reliability in this context, in particular because of the use of paracetamol. The aim of this study was to evaluate the reliability of Dexcom G6®, a recently developed continuous glucose monitoring device. Methods: We performed a prospective, observational, non-randomized, single-centre study comparing Dexcom G6® CBG level monitoring with the standard methods routinely used in this context. The standard blood glucose values were paired to the time corresponding values measured with Dexcom G6®. Agreement between the two methods and potential correlation in case of paracetamol use were calculated. Results: From May 2020 to August 2021, 36 out of 206 patients operated for isolated coronary artery bypass grafting were enrolled; 673 paired blood glucose level were analyzed. Global agreement (ρc) was 0.85 (95% C.I.: 0.84–0.86), intensive care unit agreement was 0.78 (95%C.I.: 0.74–0.82) and ward agreement was 0.91 (95%C.I.: 0.89–0.93). In the diabetic population, it was 0.87 (95%C.I.: 0.85–0.90). When paracetamol was used, the difference was 0.02 mmol/l (95%C.I.: 0.29–0.33). Conclusions: Dexcom G6® provides good blood glucose level accuracy in the postoperative context of cardiac surgery compared to the standard methods of measurements. The results are particularly reliable in the ward where the need for repeated capillary glucose measurements implies patient discomfort and time-consuming manipulations for the nursing staff.

10 December 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Elena CaporaliElena Caporali
Elena Caporali
RLRoberto Lorusso
Roberto Lorusso
TTTiziano Torre
Tiziano Torre
FTFrancesca Toto
Francesca Toto
APAlberto Guido Pozzoli
Alberto Guido Pozzoli
Enrico FerrariEnrico Ferrari
Enrico Ferrari
Background: Surgical aortic valve replacement with rapid deployment bioprosthesis guarantees good hemodynamic results but carries the risk of paravalvular leaks. To address this issue, an annulus stabilization technique has been recently developed. Methods: Clinical and hemodynamic parameters from patients treated for aortic valve replacement with the rapid deployment bioprosthesis and a concomitant annulus stabilization technique were prospectively collected and retrospectively analyzed. Echocardiographic data at discharge and at 1-year follow-up were collected and analysed. Results: A total of 57 patients (mean age 74.3 ± 6.1 years) with symptomatic aortic valve stenosis underwent aortic valve replacement with the rapid deployment bioprosthesis and concomitant annulus stabilization technique (mean valve size: 23.8 ± 1.9 mm). Combined procedures accounted for 56.1%. Hospital mortality was 1.8% and a new pacemaker for conduction abnormalities was implanted in 10 patients. The pre-discharge echocardiographic control showed absence of paravalvular leaks of any degree in all patients with mean valve gradient of 9.6 ± 4.0 mmHg. The 1-year echocardiographic control confirmed the good valve hemodynamic (mean gradient of 8.0 ± 2.8 mmHg) and absence of leaks. Conclusion: In this preliminary clinical experience, the annulus stabilization technique prevents postoperative paravalvular leaks after rapid deployment aortic valve implantation, up to 1-year postoperatively. Studies on larger series are of paramount importance to confirm the long-term efficacy of this new surgical technique.

Verified
Journal Article
Open access
PDF file
Enrico FerrariEnrico Ferrari
Enrico Ferrari
APAlberto Guido Pozzoli
Alberto Guido Pozzoli
CKCatherine Marie Klersy
Catherine Marie Klersy
FTFrancesca Toto
Francesca Toto
TTTiziano Torre
Tiziano Torre
SDStefanos Demertzis
Stefanos Demertzis
Objective: Transcatheter aortic valve replacement (TAVR) through alternative access routes is indicated in patients with severe aortic valve stenosis and diseased peripheral arteries. We analysed and compared the outcome of patients undergoing transapical (TA) and direct transaortic (TAO) TAVR procedures. Methods: Preoperative characteristics, procedural details, and thirty-day outcome of patients undergoing transapical (TA-TAVR group) and direct transaortic (TAO-TAVR group) TAVR procedures were prospectively collected and retrospectively analysed. Results: From March 2012 to March 2022, 81 TA and 82 TAO-TAVR (total: 163 cases) were performed with balloon-expanding (n = 120; 73.6%) and self-expandable (n = 43; 26.4%) valves. The mean age was 79.7 ± 6.2 and 81.9 ± 6.7 years for the TA- and TAO-TAVR groups, respectively (p = 0.032). Females were more represented in the TAO-TAVR group (56% vs. 32%; p = 0.003) while TA-TAVR patients showed a higher prevalence of previous vascular surgery (20% vs. 6%; p = 0.01), previous cardiac surgery (51% vs. 3.6%; p < 0.001), and porcelain aorta (22% vs. 5%; p = 0.001). The mean ejection fraction was 49.0 ± 14.6% (TA) and 53.5 ± 12.2% (TAO) (p = 0.035) while mean gradients were 35.6 ± 13.2 mmHg (TA) and 40.4 ± 16.1 mmHg (TAO) (p = 0.045). The median EuroSCORE-II was 5.0% (IQR: 3.0–11.0) and 3.9% (IQR: 2.5–5.4) for the TA- and TAO-TAVR groups, respectively (p = 0.005). The procedural time was shorter for TA procedures (97 min (IQR: 882–118) vs. 102 min (IQR: 88–129); p = 0.133). Mortality at day 30 was 6% in both groups (p = 1.000); the permanent pacemaker implantation rate was similar (8.6% vs. 9.7%; p = 1.000), and hospital stay was shorter for the TAO group (8 days (IQR: 6–11) vs. 10 days (IQR: 7–13); p = 0.025). Conclusions: Our results show that transapical and direct transaortic TAVR in high-risk patients with diseased peripheral arteries provide satisfactory clinical results with similar thirty-day outcomes.

24 October 2023 in Asian Cardiovascular and Thoracic Annals
Verified
Journal Article
Closed access
APAlberto Guido Pozzoli
Alberto Guido Pozzoli
GSGiuseppina Gabriella Surace
Giuseppina Gabriella Surace
TTTiziano Torre
Tiziano Torre
PBPietro Bagnato
Pietro Bagnato
MGMichele Gallo
Michele Gallo
SDStefanos Demertzis
Stefanos Demertzis
Background: The quality of a myocardial protection of a single-dose del Nido cardioplegia versus multiple dose blood-based cardioplegia on myocardial injury, outcomes and operative times in patients undergoing minimally invasive aortic valve replacement is basically unreported. Methods and Results: Preoperative and post-operative data, as well as technical details from isolated minimally invasive aortic valve replacements, performed using single-dose or multiple-dose cardioplegia were prospectively collected and retrospectively analysed. A total of 110 patients undergoing minimally invasive valve replacements at our institution composed two groups: 55 patients in the blood cardioplegia group (BloCa) and 55 in the del Nido group (DeNiCa). The two-matched groups were comparable in terms of preoperative variables. In the DeNiCa group, there was a statistically significant less need for cardiac defibrillation after aortic cross-clamp release ( p < 0.001). Moreover, the BloCa group received intraoperatively more blood transfusions ( p = 0.001) and more insulin administration for higher glucose levels ( p < 0.001). The BloCa group showed higher intraoperative lactate levels ( p = 0.01). Need for post-operative inotropic and vasoactive support, Creatine Kinase-MB levels after 6 and 12 h, onset of post-operative atrial fibrillation and length of stay were similar. No deaths occurred in neither groups. Conclusion: Single-dose del Nido cardioplegia in the setting of minimally invasive aortic surgery seems to offer adequate myocardial protection, comparable to multiple dose hematic cardioplegia. It has been documented a lower peri-operative need of defibrillation after cross-clamp release, lactate- and glucose peak values, as well as less blood transfusions compared to blood cardioplegic strategy.

Verified
Journal Article
Open access
PDF file
FTFrancesca Toto
Francesca Toto
LLLaura Anna Leo
Laura Anna Leo
CKCatherine Marie Klersy
Catherine Marie Klersy
TTTiziano Torre
Tiziano Torre
TTThomas Theologou
Thomas Theologou
Enrico FerrariEnrico Ferrari
Enrico Ferrari
Aims of the Study: We evaluated the clinical outcome and the hemodynamic and freedom from structural valve degeneration of two standard aortic bioprostheses. Methods: Clinical results, echocardiographic findings and follow-up data of patients operated for isolated or combined aortic valve replacement with the Perimount or the Trifecta bioprosthesis were prospectively collected, retrospectively analysed and compared. We weighted all the analyses by the inverse of the propensity of choosing either valves. Results: Between April 2015 and December 2019, 168 consecutive patients (all comers) underwent aortic valve replacement with Trifecta (n = 86) or Perimount (n = 82) bioprostheses. Mean age was 70.8 ± 8.6 and 68.8 ± 8.6 years for the Trifecta and Perimount groups, respectively (p = 0.120). Perimount patients presented a greater body mass index (27.6 ± 4.5 vs. 26.0 ± 4.2; p = 0.022), and 23% of them suffered from angina functional class 2–3 (23.2% vs. 5.8%; p = 0.002). Mean ejection fraction was 53.7 ± 11.9% (Trifecta) and 54.5 ± 10.4% (Perimount) (p = 0.994), with mean gradients of 40.4 ± 15.9 mmHg (Trifecta) and 42.3 ± 20.6 mmHg (Perimount) (p = 0.710). Mean EuroSCORE-II was 7 ± 11% and 6 ± 9% for the Trifecta and Perimount group, respectively (p = 0.553). Trifecta patients more often underwent isolated aortic valve replacement (45.3% vs. 26.8%; p = 0.016) and annulus enlargement (10.5% vs. 2.4%; p = 0.058). All-cause mortality at 30 days was 3.5% (Trifecta) and 8.5% (Perimount), (p = 0.203) while new pacemaker implantation (1.2% vs. 2.5%; p = 0.609) and stroke rate (1.2% vs. 2.5%; p = 0.609) were similar. Acute MACCE were observed in 5% (Trifecta) and 9% (Perimount) of patients with an unweighted OR of 2.22 (95%CI 0.64–7.66; p = 0.196) and a weighted OR of 1.10 (95%CI: 0.44–2.76, p = 0.836). Cumulative survival at 24 months was 98% (95%CI: 0.91–0.99) and 96% (95%CI: 0.85–0.99) for Trifecta and Perimount groups, respectively (log-rank test; p = 0.555). The 2-year freedom from MACCE was 94% (95%CI: 0.65–0.99) for Trifecta and 96% (95%CI: 0.86–0.99) for Perimount (log-rank test; p = 0.759, HR 1.46 (95%CI: 0.13–16.48)) in the unweighted analysis (not estimable in the weighted analysis). During the follow-up (median time: 384 vs. 593 days; p = 0.0001) there were no re-operations for structural valve degeneration. Mean valve gradient at discharge was lower for Trifecta across all valve sizes (7.9 ± 3.2 vs. 12.1 ± 4.7 mmHg; p < 0.001), but the difference did not persist during follow-up (8.2 ± 3.7 mmHg for Trifecta, 8.9 ± 3.6 mmHg for Perimount; p = 0.224); Conclusions: Postoperative outcome and mid-term follow-up were similar. An early better hemodynamic performance was detected for the Trifecta valve but did not persist over time. No difference in the reoperation rate for structural valve degeneration was found.