Wichana Chamroonrat

Dr. Wichana Chamroonrat

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2016 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SASasithorn Amnuaywattakorn
Sasithorn Amnuaywattakorn
CSChanika Sritara
Chanika Sritara
CUChirawat Utamakul
Chirawat Utamakul
WCWichana Chamroonrat
Wichana Chamroonrat
AKArpakorn Kositwattanarerk
Arpakorn Kositwattanarerk
BOBoonsong Ongphiphadhanakul
Boonsong Ongphiphadhanakul
Trabecular bone score (TBS), which has been proposed to be used in complementary with bone mineral density (BMD) to improve the assessment of fracture risk, is negatively associated with body mass index (BMI). The effect of soft tissue, which is expected to be thicker in subjects with high BMI, on TBS was studied using three scan types: Hologic with fast array mode (Hfa), Hologic with high definition mode (Hhd), and GE-Lunar iDXA. A spine phantom provided by Hologic for routine quality control procedure was scanned using three scan types: Hfa, Hhd, and iDXA. The phantom was scanned with an overlying soft tissue equivalent material (bolus used in radiotherapy) of 0 (without), 1, 2.5, 3.5, 5 and 7.5 cm thick. For each setting, 30 acquisitions were performed in the same way as for the quality control procedure. TBS was calculated using TBS iNsight® software version 2.1 on the same regions of interest as those used for lumbar spine BMD. Mean ± SD TBS of the phantom (without overlying soft tissue) were 1.379 ± 0.018, 1.430 ± 0.009, and 1.423 ± 0.005 using Hfa, Hhd, and iDXA, respectively. A one-way repeated measures ANOVA showed that there were statistically differences in TBS due to different thicknesses of soft tissue equivalent materials for all three scan types (p < 0.001). A Tukey post-hoc test revealed that the decrease in TBS was statistically significant (p < 0.001) when the soft tissue thickness was 1 cm (−0.0246 ± 0.0044, −0.0319 ± 0.0036, and −0.0552 ± 0.0015 for Hfa, Hhd, and iDXA, respectively). Although to a lesser degree, the effects were also statistically significant for BMD (p < 0.05): an increase for Hfa and Hhd but a decrease for iDXA. However, these changes did not exceed the least significant change (LSC) derived from patients. Increased soft tissue thickness results in lower TBS value. Although BMD is also affected, it is unlikely to pose a clinical problem because the change is unlikely to exceed the patient-derived LSC.

3 August 2022 in Molecules
Verified
Journal Article
Open access
PDF file
CSChaninart Sakulpisuti
Chaninart Sakulpisuti
PCPutthiporn Charoenphun
Putthiporn Charoenphun
WCWichana Chamroonrat
Wichana Chamroonrat
Differentiated thyroid cancer (DTC), arising from thyroid follicular epithelial cells, is the most common type of thyroid cancer. Despite the well-known utilization of radioiodine treatment in DTC, i.e., iodine-131, radioiodine imaging in DTC is typically performed with iodine-123 and iodine-131, with the current hybrid scanner performing single photon emission tomography/computed tomography (SPECT/CT). Positron emission tomography/computed tomography (PET/CT) provides superior visualization and quantification of functions at the molecular level; thus, lesion assessment can be improved compared to that of SPECT/CT. Various types of cancer, including radioiodine-refractory DTC, can be detected by 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG), the most well-known and widely used PET radiopharmaceutical. Several other PET radiopharmaceuticals have been developed, although some are limited in availability despite their potential clinical utilizations. This article aims to summarize PET radiopharmaceuticals in DTC, focusing on molecular pathways and applications.

18 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
MCMolaya Chaisen
Molaya Chaisen
CSChanika Sritara
Chanika Sritara
NCNiyata Chitrapazt
Niyata Chitrapazt
CSChaiyawat Suppasilp
Chaiyawat Suppasilp
WCWichana Chamroonrat
Wichana Chamroonrat
KTKanungnij Thamnirat
Kanungnij Thamnirat
Background: Osteoporosis is commonly evaluated using dual-energy X-ray absorptiometry (DXA) for bone mineral density (BMD). Non-contrast computed tomography (CT) scans provide an alternative for opportunistic osteoporosis assessment. This study aimed to evaluate screening thresholds for osteoporosis based on CT attenuation values in Hounsfield units (HU) of L1–L4 vertebrae from CT scans of the abdominal region, compared to DXA assessments of the lumbar spine and hips. Methods: Conducted retrospectively over approximately two years, the analysis included 109 patients who had both CT and DXA scans within 12 months, excluding those with metal artifacts affecting the vertebrae. CT attenuation values in the trabecular region of the vertebrae were measured and compared among three groups based on the lowest T-score from DXA. Results: In a predominantly female cohort (mean age 66.3 years), the lowest CT attenuation values for L1–L4 vertebrae showed a moderate correlation with the lowest T-score, with a Pearson correlation coefficient of 0.542 (95% CI: 0.388, 0.667). A HU threshold of ≤142 at the L1 vertebra showed 91.9% sensitivity and 48.4% specificity, while a threshold of ≤160 HU showed 97.3% sensitivity and 31.3% specificity for screening osteoporosis. Conclusions: This study supports the use of non-contrast CT with these HU thresholds as an opportunistic tool for osteoporosis assessment.

1 September 2020 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
KAKingthong Anurat
Kingthong Anurat
CKChaiyos Khongkhatithum
Chaiyos Khongkhatithum
OPOraluck Pattanaprateep
Oraluck Pattanaprateep
WCWichana Chamroonrat
Wichana Chamroonrat
ABAtthaporn Boongird
Atthaporn Boongird
LTLunliya Thampratankul
Lunliya Thampratankul


1 March 2016 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
YAYoch Anongpornjossakul
Yoch Anongpornjossakul
CUChirawat Utamakul
Chirawat Utamakul
WCWichana Chamroonrat
Wichana Chamroonrat
AKArpakorn Kositwattanarerk
Arpakorn Kositwattanarerk
KTKanungnij Thamnirat
Kanungnij Thamnirat
CSChanika Sritara
Chanika Sritara
A 72-year-old woman with papillary thyroid cancer post-total thyroidectomy was referred for post-I treatment whole-body scan. Images revealed focal uptake within the gallbladder. Cholecystectomy was subsequently performed, and the pathology report showed well-differentiated adenocarcinoma. Given a history of papillary thyroid cancer, the iodine uptake was reasonably explained as metastasis; however, gallbladder metastasis was extremely infrequent. Literature described the incidental radioiodine retention in the gallbladder as false-positive findings, which can be normal variants or benign hepatobiliary conditions. Primary gallbladder malignancy could be counted for another possibility despite controversial mechanism of uptake.