Teruo Fujii

Prof. Teruo Fujii


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Drug Metabolism and Pharmacokinetics
Verified
Journal Article
Open access
Hiroshi KimuraHiroshi Kimura
Hiroshi Kimura
YSYasuyuki Sakai
Yasuyuki Sakai
TFTeruo Fujii
Teruo Fujii
Although animal experiments are indispensable for preclinical screening in the drug discovery process, various issues such as ethical considerations and species differences remain. To solve these issues, cell-based assays using human-derived cells have been actively pursued. However, it remains difficult to accurately predict drug efficacy, toxicity, and organs interactions, because cultivated cells often do not retain their original organ functions and morphologies in conventional in vitro cell culture systems. In the μTAS research field, which is a part of biochemical engineering, the technologies of organ-on-a-chip, based on microfluidic devices built using microfabrication, have been widely studied recently as a novel in vitro organ model. Since it is possible to physically and chemically mimic the in vitro environment by using microfluidic device technology, maintenance of cellular function and morphology, and replication of organ interactions can be realized using organ-on-a-chip devices. So far, functions of various organs and tissues, such as the lung, liver, kidney, and gut have been reproduced as in vitro models. Furthermore, a body-on-a-chip, integrating multi organ functions on a microfluidic device, has also been proposed for prediction of organ interactions. We herein provide a background of microfluidic systems, organ-on-a-chip, Body-on-a-chip technologies, and their challenges in the future.

4 April 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Hiroshi KimuraHiroshi Kimura
Hiroshi Kimura
TYTakatoki Yamamoto
Takatoki Yamamoto
HSHitomi Sakai
Hitomi Sakai
YSYasuyuki Sakai
Yasuyuki Sakai
TFTeruo Fujii
Teruo Fujii
Conventional cell-based assays in life science and medical applications can be difficult to maintain functionally over long periods. Microfluidics is an emerging technology with potential to provide integrated environments for cell maintenance, continuous perfusion, and monitoring. In this study, we developed an integrated microfluidic device with on-chip pumping and detection functionalities. The microfluidic structure in the device is divided into two independent channels separated by a semipermeable membrane on which cells are inoculated and cultured. Perfusion and fluorescence measurements of culture media for each channel can be conducted by the on-chip pumping system and optical fiber detection system. Performance of the device was examined through long-term culture and monitoring of polarized transport activity of intestinal tissue models (Caco-2 cells). The cells could be cultured for more than two weeks, and monolayer transport of rhodamine 123 was successfully monitored by on-line fluorescent measurement. This device may have applications in toxicity testing and drug screening.

19 February 2016 in Scientific Reports
Verified
Journal Article
Open access
MKMitsuru Komeya
Mitsuru Komeya
Hiroshi KimuraHiroshi Kimura
Hiroshi Kimura
HNHiroko Nakamura
Hiroko Nakamura
TYTetsuhiro Yokonishi
Tetsuhiro Yokonishi
TSTakuya Sato
Takuya Sato
TOTakehiko Ogawa
Takehiko Ogawa
In contrast to cell cultures, particularly to cell lines, tissues or organs removed from the body cannot be maintained for long in any culture conditions. Although it is apparent that in vivo regional homeostasis is facilitated by the microvascular system, mimicking such a system ex vivo is difficult and has not been proved effective. Using the culture system of mouse spermatogenesis, we addressed this issue and devised a simple microfluidic device in which a porous membrane separates a tissue from the flowing medium, conceptually imitating the in vivo relationship between the microvascular flow and surrounding tissue. Testis tissues cultured in this device successfully maintained spermatogenesis for 6 months. The produced sperm were functional to generate healthy offspring with micro-insemination. In addition, the tissue kept producing testosterone and responded to stimulation by luteinizing hormone. These data suggest that the microfluidic device successfully created in vivo-like conditions, in which testis tissue maintained its physiologic functions and homeostasis. The present model of the device, therefore, would provide a valuable foundation of future improvement of culture conditions for various tissues and organs, and revolutionize the organ culture method as a whole.

5 February 2003 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
SCS. Camou
S. Camou
HFH. Fujita
H. Fujita
TFTeruo Fujii
Teruo Fujii
In this paper, the fabrication and characterization of PDMS 2D-optical lenses are reported. These lenses are designed in order to improve the performance of fluorescent spectroscopy detection performed on a portable chip using optical fibers. The fabrication process of the PDMS layer is first detailed, and the patterns are then checked with a SEM. By comparing various interfacial structures, it is shown that the beam properties of the light coming out from the fiber can be modified depending on the lens curvature radius. As a consequence, for a constant dye concentration, the use of such lenses can increase the intensity of fluorescent response close to the fiber or far from the fiber, compared to the same design with a flat interface. This excitation improvement corresponding to a stronger response from the dye then consequently leads to around three times higher sensitivity of the on-chip detection method for fluorescent spectroscopy.

1 June 2011 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
YNYosuke Nakao
Yosuke Nakao
Hiroshi KimuraHiroshi Kimura
Hiroshi Kimura
YSYasuyuki Sakai
Yasuyuki Sakai
TFTeruo Fujii
Teruo Fujii
In this study, we propose a microfluidic cell culture device mimicking the microscopic structure in liver tissue called hepatic cords. The cell culture area of the device was designed to align hepatocytes in two lines in a similar way to hepatic cords. Thanks to the structural design together with a cell seeding procedure, rat primary hepatocytes were successfully aligned in two lines and cultured under perfusion condition. It is shown that aligned hepatocytes gradually self-organize and form bile canaliculi along the hepatic cord-like structure. The present technique to culture hepatocytes with functional bile canaliculi could be used as an alternative to animal testing in the field of drug discovery and toxicological studies, and also be beneficial to tissue engineering applications.

1 June 2015 in SLAS Technology
Verified
Journal Article
Open access
Hiroshi KimuraHiroshi Kimura
Hiroshi Kimura
TITakashi Ikeda
Takashi Ikeda
HNHidenari Nakayama
Hidenari Nakayama
YSYasuyuki Sakai
Yasuyuki Sakai
TFTeruo Fujii
Teruo Fujii
Testing of drug effects and cytotoxicity by using cultured cells has been widely performed as an alternative to animal testing. However, the estimation of pharmacokinetics by conventional cell-based assay methods is difficult because of the inability to evaluate multiorgan effects. An important challenge in the field is to mimic the organ-to-organ network in the human body by using a microfluidic network connecting small-scale tissues based on recently emerging MicroTAS (Micro Total Analysis Systems) technology for prediction of pharmacokinetics. Here, we describe an on-chip small intestine–liver coupled model for pharmacokinetic studies. To construct an in vitro pharmacokinetic model that appropriately models in vivo conditions, physiological parameters such as the structure of internal circulation, volume ratios of each organ, and blood flow ratio of the portal vein to the hepatic artery were mimicked using microfluidic networks. To demonstrate interactions between organs in vitro in pharmacokinetic studies, Caco-2, HepG2, and A549 cell cultures were used as organ models of the small intestine, liver, and lung, respectively, and connected to each other through a microporous membrane and microchannels to prepare a simple model of a physiological organ-to-organ network. The on-chip organ model assay using three types of substrate—epirubicine (EPI), irinotecan (CPT-11), and cyclophosphamide (CPA)—were conducted to model the effects of orally administered or biologically active anticancer drugs. The result suggested that the device can replicate physiological phenomena such as activity of the anticancer drugs on the target cells. This microfluidic device can thus be used as an in vitro organ model to predict the pharmacokinetics of drugs in the human body and may thus provide not only an alternative to animal testing but also a method of obtaining parameters for in silico models of physiologically based pharmacokinetics.