Jason Fisher

Mr. Jason Fisher

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LILeonidas G. Ioannou
Leonidas G. Ioannou
UCUrša Ciuha
Urša Ciuha
JFJason Fisher
Jason Fisher
LTLydia Tsoutsoubi
Lydia Tsoutsoubi
KTKunihito Tobita
Kunihito Tobita
IMIgor Mekjavic
Igor Mekjavic
Background: Prevention plays a key role in ensuring health and safety and is particularly important in scenarios when life is threatened. Adverse thermal conditions are experienced by billions of people daily, affecting the human capacity for thermoregulation and increasing the risks of life-threatening accidents, diseases, and fatalities. The aim of this study was to develop and validate a new, freely accessible method that will ultimately allow health, as well as exercise and labour organizations, to predict and potentially mitigate the physiological strain experienced by people who exercise or work in thermally stressful environmental conditions. Methods: First, we used concurrent technological advances and thermophysiological modelling to (i) develop a mobile phone application that predicts the physiological heat strain experienced by individuals conducting physical activity in adverse environmental conditions, and (ii) provide them with individualized heat mitigation strategies. Second, to examine the construct validity of the newly developed mobile phone application, core body temperature was recorded using gastrointestinal thermometry in 37 healthy soldiers during different activities. These data were used to examine the predictive capacity of our application in pre-classifying individuals with an increased risk of experiencing elevated physiological heat strain during work based on the guidelines (core body temperature ≥ 38 °C) of the World Health Organization. Results: The core body temperature predictions made by the mobile phone application were positively related (r = 0.57, p < 0.05) with the actual physiological measurements taken by our participants (mean absolute error: 0.28 °C). More importantly, our application correctly predicted 93% of occurrences of elevated physiological heat strain and 90% of those that were not (overall accuracy: 92%). Conclusions: Mobile phone applications integrating thermophysiological models can predict the physiological heat strain experienced by an individual, but it remains to be studied whether the suggested heat mitigation strategies can reduce or prevent adverse impacts.

22 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JFJason Fisher
Jason Fisher
UCUrša Ciuha
Urša Ciuha
MTMike Tipton
Mike Tipton
LILeonidas G. Ioannou
Leonidas G. Ioannou
IMIgor Mekjavic
Igor Mekjavic
There is a need to rapidly screen individuals for heat strain and fever using skin temperature (Tsk) as an index of deep body temperature (Tb). This study’s aim was to assess whether Tsk could serve as an accurate and valid index of Tb during a simulated heatwave. Seven participants maintained a continuous schedule over 9-days, in 3-day parts; pre-/post-HW (25.4 °C), simulated-HW (35.4 °C). Contact thermistors measured Tsk (Tforehead, Tfinger); radio pills measured gastrointestinal temperature (Tgi). Proximal-distal temperature gradients (ΔTforehead–finger) were also measured. Measurements were grouped into ambient conditions: 22, 25, and 35 °C. Tgi and Tforehead only displayed a significant relationship in 22 °C (r: 0.591; p < 0.001) and 25 °C (r: 0.408; p < 0.001) conditions. A linear regression of all conditions identified Tforehead and ΔTforehead–finger as significant predictors of Tgi (r2: 0.588; F: 125.771; p < 0.001), producing a root mean square error of 0.26 °C. Additional residual analysis identified Tforehead to be responsible for a plateau in Tgi prediction above 37 °C. Contact Tforehead was shown to be a statistically suitable indicator of Tgi in non-HW conditions; however, an error of ~1 °C makes this physiologically redundant. The measurement of multiple sites may improve Tb prediction, though it is still physiologically unsuitable, especially at higher ambient temperatures.

3 August 2024 in Journal of Thermal Biology
Verified
Journal Article
Open access
JFJason Fisher
Jason Fisher
UCUrša Ciuha
Urša Ciuha
IMIgor Mekjavic
Igor Mekjavic
Under simultaneous ambient temperature and postural stressors, integrated regional blood flow responses are required to maintain blood pressure and thermoregulatory homeostasis. The aim of the present study was to assess the effect of ambient temperature and body posture on regional regulation of microvascular blood flow, specifically in the arms and legs. Participants (N = 11) attended two sessions in which they experienced transient ambient conditions, in a climatic chamber. During each 60-min trial, ambient temperature increased from 15.7 (0.6) °C to 38.9 (0.6) °C followed by a linear decrease, and the participants were either standing or in a supine position throughout the trial; relative humidity in the chamber was maintained at 25.9 (6.6) %. Laser doppler flowmetry of the forearm (SkBFarm) and calf (SkBFcalf), and haemodynamic responses (heart rate, HR; stroke volume, SV; cardiac output, CO; blood pressure, BP), were measured continuously. Analyses of heart rate variability and wavelet transform were also conducted. SkBFarm increased significantly at higher ambient temperatures (p = 0.003), but not SkBFcalf. The standing posture caused lower overall SkBF in both regions throughout the protocol, regardless of temperature (p < 0.001). HR and BP were significantly elevated, and SV significantly lowered, in response to separate and combined effects of higher ambient temperatures and a standing position (all p < 0.05); CO remained unchanged. Mechanistic analyses identified greater sympathetic nerve activation, and higher calf myogenic activation at peak temperatures, in the standing condition. Mechanistically and functionally, arm vasculature responds to modulation from both thermoregulation and baroreceptor activity. The legs, meanwhile, are more sensitive to baroreflex regulatory mechanisms.

2 April 2025 in European Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
JFJason Fisher
Jason Fisher
UCUrša Ciuha
Urša Ciuha
PDPierre Denise
Pierre Denise
AMAdam C. McDonnell
Adam C. McDonnell
HNHervé Normand
Hervé Normand
IMIgor Mekjavic
Igor Mekjavic
Under simultaneous environmental and gravitational stressors, integrated vascular responses maintain homeostatic balance via coordinated baro- and thermo-regulatory action. The effect of temperature and hypoxia at an elevated gravitational vector on the interaction of these systems was examined. Ten male participants experienced either cool (18.4 °C) or warm (29.1 °C) ambient temperatures in normoxia (partial pressure of oxygen, PIO2 = 133 mmHg) or hypoxia (PIO2 = 92 mmHg). Cardiovascular (heart rate, HR; arterial pressure, MAP; cardiac output, CO; stroke volume, SV; skin blood flow, SkBF) and thermoregulatory (skin temperature; core temperature) responses were monitored during standing (NG), and supine centrifugation at ground reaction forces (GRF) measured with a force platform at 1GRF and 2GRF. At 2GRF, warm and hypoxic conditions reduced the test duration by 16%. No differences were observed between NG and 1GRF in any variable; however, 2GRF significantly raised HR by 29.3% and MAP by 12.6%, and lowered SV by 22.2%. Warm condition significantly increased HR, and significantly decreased MAP and SV compared to the cool condition, by 17.8%, 6.1%, and 5.8%, respectively. Hypoxia had no effect on any variable. Arm SkBF significantly decreased by 33.3% with increasing artificial gravity, whereas leg SkBF increased by 38.7%. Higher ambient temperatures had no effect on leg SkBF, but significantly increased arm SkBF by 38.7%. Human tolerance to passive centrifugation is significantly lower at 2GRF, and further affected by the ambient conditions. Haemodynamic and leg SkBF responses in higher temperature and Gz conditions were frequently unable to prevent pre-syncopal symptoms. Finally, arm SkBF was modulated by both baroreflex and thermoregulation, and the baroreflex alone in leg SkBF.