Victor Kohn

Dr. Victor Kohn

orcid

Research Focus & Metrics

Academic Career Length

52Years (1975-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 1995 in Review of Scientific Instruments
Verified
Journal Article
Closed access
ASA. Snigirev
A. Snigirev
ISI. Snigireva
I. Snigireva
VKVictor Kohn
Victor Kohn
SKS. Kuznetsov
S. Kuznetsov
ISI. Schelokov
I. Schelokov
Coherent properties of the x-ray beam delivered at the ESRF allow the observation of very weak perturbations of the wave front, resulting in the phase contrast. A straightforward experimental setup for phase contrast imaging is proposed and used to record holographic images from organic samples of 10–100 μm at energy 10–50 keV with the contrast up to 50%–100%. The theory of phase contrast imaging is considered and some theoretical estimations are made to reveal the performance of the proposed technique in terms of resolution, sensitivity, geometrical requirements, and energy range applicability. It is found that for carbon-based fibers a detectable size with 2% contrast is 0.1 μm for 10 keV and −1 μm for 100 keV. It is demonstrated that the fine interference structure of the image is very sensitive to the shape, density variation, and internal structure of the sample. Some prospects for the practical use and future development of the new coherent techniques such as phase contrast microscopy, microtomography, holography, and interferometry at high energies are also discussed.

1 November 1996 in Nature
Verified
Journal Article
Closed access
ASA. Snigirev
A. Snigirev
VKVictor Kohn
Victor Kohn
ISI. Snigireva
I. Snigireva
BLB. Lengeler
B. Lengeler

1 February 1979 in Journal of Physics C: Solid State Physics
Verified
Journal Article
Closed access
YKYu Kagan
Yu Kagan
AAA M Afanas'EV
A M Afanas'EV
VKVictor Kohn
Victor Kohn

1 March 2000 in Hyperfine Interactions
Verified
Journal Article
Closed access
PDF file
VKVictor Kohn
Victor Kohn
ACA.I. Chumakov
A.I. Chumakov

23 September 1996 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CRC. Raven
C. Raven
ASA. Snigirev
A. Snigirev
ISI. Snigireva
I. Snigireva
PSP. Spanne
P. Spanne
ASA. Souvorov
A. Souvorov
VKVictor Kohn
Victor Kohn
Cross-sectional information on low electron density materials can be obtained by probing a sample with a 60 keV coherent synchrotron x-ray beam in an in-line holography setup. Such objects are practically transparent to high energy x rays and create a phase shift of the wave front only. Images of a 100 μm diameter boron fiber were recorded in the extreme near field region, where contrast occurs only at interfaces between regions with different decrements of refractive index. Theoretical simulations are in good agreement with the measured intensities. In a tomographic reconstruction the 15 μm diameter core of the fiber is clearly visible, demonstrating the possibility of reconstructing three dimensional interfaces between low density materials.

1 February 1998 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ASA. Snigirev
A. Snigirev
VKVictor Kohn
Victor Kohn
ISI. Snigireva
I. Snigireva
ASA. Souvorov
A. Souvorov
BLB. Lengeler
B. Lengeler
Compound lenses made from low-Z materials (e.g., Be, B, C, and Al) set up as a linear array of refractive lenses are proposed for submicrometer focusing of high-energy x rays (>5 keV) in one or two dimensions. A theory of focusing based on Maxwell’s equation and the Fresnel–Kirchhoff approach is presented. Compound refractive lenses were manufactured by drilling into an Al block a linear array of 200 closely spaced holes 0.5 mm in diameter for linear focusing and two crossed arrays of 100 holes each for point focusing. Focal spots of 3.7 μm and 8 μm × 18 μm were obtained at 30 keV for linear and two-dimensional lenses, respectively. Different technologies of manufacturing and possible applications of the proposed lenses are discussed.