Wen-Pei Sung

Prof. Dr. Wen-Pei Sung

National Chin-Yi University of Technology, Taichung, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
MWMing-Ju Wu
Ming-Ju Wu
YFYun-Shu Feng
Yun-Shu Feng
WSWen-Pei Sung
Wen-Pei Sung
RSRao Y. Surampalli
Rao Y. Surampalli
Indoor air quality has become a critical issue because people spend most of their time in the indoor environment. The factors that influence indoor air quality are very important to environmental sanitation and air quality improvement. This study focuses on monitoring air quality, colony counts, and bacteria species of the indoor air of a nursing care institution. The regular colony counts in two different wards range from 55 to 600 cfu m−3. Regression analysis results indicate that the bacterial colony counts have close correlation with relative humidity or carbon dioxide (CO2) but not with carbon monoxide (CO) or ozone (O3). Real-time PCR was used to quantify the bacterial pathogens of nosocomial infection, including Acinetobacter baumannii, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, and methicillin-sensitive Staphylococcus aureus. The most abundant bacteria species in the air of the nursing care institution is E. coli.

1 March 2010 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
YZYu-Kuang Zhao
Yu-Kuang Zhao
WSWen-Pei Sung
Wen-Pei Sung
TTTzai-Tang Tsai
Tzai-Tang Tsai
HWHsien-Jung Wang
Hsien-Jung Wang
The deterioration of indoor air quality because of airborne bacterial consortia is a widespread environmental problem. The main objective of this study is to evaluate the feasibility of ap...

15 July 2014 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
MSMing-Hsiang Shih
Ming-Hsiang Shih
WSWen-Pei Sung
Wen-Pei Sung
The capacity of buildings to resist external excitation is an important factor to consider for the structural design of buildings. When subject to external excitation, a building may suffer a certain degree of damages, and its residual capacity to resist external excitation cannot be evaluated. In this research, dynamic digital image correlation method combined with parameter evaluation available in system identification is used to evaluate the structural capacity to resist external excitation. The results reveal possible building latent safety problems so that timely structural reinforcement or dismantling of the building can be initiated to alleviate further damages. The results of experiments using the proposed method conform to the results obtained using the conventional method, but this method is more convenient and rapid than the latter in the subsequent procedure of data processing. If only the frequency change is used, the damages suffered by the building can be detected, but the damage location is not revealed. The interstory drift mode shape (IDMS) based on the characteristic of story drift has higher sensitivity than the approximate story damage index (ADSI) method based on modal frequency and vibration type; however, both indices can be used to determine the degree and location of building damages.

1 March 2011 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
WSWen-Pei Sung
Wen-Pei Sung
TTT. T. Tsai
T. T. Tsai
MWM. J. Wu
M. J. Wu
HWH. J. Wang
H. J. Wang
RSR. Y. Surampalli
R. Y. Surampalli
Deterioration of indoor air quality attributable to airborne bacterial consortia is a widespread environmental problem. The main objective of this study is to evaluate the feasibility of applying the syngetic effect of nano-Ag/TiO2 as a photocatalyst and UV light to enhance the disinfecting capability of full-scale bacterial restraining equipment on-site in the National Museum of Natural Science and a medical-nursing institute. The influence of initial counts of total airborne bacteria and volume of space on the efficiency of bacterial restraining have been studied. In the case of museum application, a higher initial total bacterial count leads to better bacterial restraining rates; Site A (initial total bacterial counts = 506 CFU/m3) has the best bacterial restraining rate (92%) as compared with Site B (69%, initial total bacterial counts = 158 CFU/m3) and Site C (80%, initial total bacterial counts = 338 CFU/m3) after 24 h of operation. Higher initial counts of total airborne bacteria lead to an incr...

16 July 2020 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
MSMing-Hsiang Shih
Ming-Hsiang Shih
WSWen-Pei Sung
Wen-Pei Sung

1 January 2019 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
MSMing-Hsiang Shih
Ming-Hsiang Shih
WSWen-Pei Sung
Wen-Pei Sung
When natural disasters cause bridges to collapse, the delivery of rescue equipment and supplies to remote disaster areas is impeded and disaster relief efforts are thus delayed. In this study, to enhance and improve light bridges for disaster relief, a neutral equilibrium mechanism (NEM) is proposed to adjust the internal force of the bridge and reduce the deformation of the bridge. The NEM is installed at the center of a bridge to form a virtual bridge pier. A prototype of the NEM, composed of a pair of prestressed steel tendons, two pairs of anchor seats, a rotation cantilever arm mechanism, and a pair of radio‐controlled (RC) servos, is proposed to test and verify the control effect of a bridge with the NEM. Test and analysis results show the following: (1) The rotation angle of the cantilever arm can be rotated by the RC servo to appropriate angles to provide adequate upwards resultant force to balance the moving load. (2) The vertical displacement of the bridge can be controlled to close to zero by this proposed NEM. (3) The maximum vertical displacement at the midpoint of a bridge with the NEM control mechanism can be controlled to far below 1/400 of the span of the bridge required by the design criteria. (4) A bridge under the control of an NEM under a low‐speed moving load with various control gains achieves fine displacement reduction effects, but the displacement reduction effect for a high‐speed moving load with low control gain decreases. Test results also show that the bearing capacity of an existing bridge with an NEM can be increased and the weight of the bridge can be reduced. The effective span of a bridge can be increased without increasing the depth of the cross section. The feasibility and practicality of applying this proposed NEM to form a virtual pier of a bridge have been verified in this study.