Glowka Pawel

Mr. Glowka Pawel


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDPrzemysław Daroszewski
Przemysław Daroszewski
Juliusz HuberJuliusz Huber
Juliusz Huber
KKKatarzyna Kaczmarek
Katarzyna Kaczmarek
PJPiotr Janusz
Piotr Janusz
GPGlowka Pawel
Glowka Pawel
TKTomasz Kotwicki
Tomasz Kotwicki
Introduction: A practical solution to the incidental unreliability of intraoperative neuromonitoring (IONM) may be the simultaneous neurophysiological recording and control of the surgical field through a camera (the concept of “Real-time” IONM). During “Real-time” IONM, the surgeon is immediately warned about the possibility of damage to the neural structures during, but not after, standard idiopathic scoliosis (IS) corrective surgery procedures (the concept of “Surgeon–neurophysiologist” interactive, verbal IONM). This study aimed to compare the advantages, utilities, reliabilities, and time consumption of the two IONM scenarios. Methods: Studies were performed in two similar groups of patients undergoing surgery primarily due to Lenke 2 idiopathic scoliosis (N = 120), when both IONM approaches were applied. Neurophysiological evaluations of the spinal transmission were performed pre- (T0), intra- (before (T1) and after (T2) surgery), and postoperatively (T3), as well as once in healthy volunteers (control, N = 60). Non-invasive and innovative recordings of the motor evoked potentials (MEPs) bilaterally from the peroneal (PER) nerve and tibialis anterior (TA) muscle were performed with surface electrodes as a result of transcranial magnetic stimulation (TMS) or electrical stimulation (TES) at T0–T3. Results: In both groups, the MEP amplitudes and latencies recorded from the PER nerve were approximately 67% lower and 3.1 ms shorter than those recorded from the TA muscle. The MEP recording parameters differed similarly at T0–T3 compared to the control group. In all patients, the MEP parameters induced by TMS (T0) and TES (T1) did not differ. The MEP amplitude parameters recorded from the TA and PER at T1 and T2 indicated a bilateral improvement in the neural spinal conduction due to the surgical intervention. The TMS-induced MEP amplitude at T3 further increased bilaterally. In both IONM groups, an average 51.8 BIS level of anesthesia did not affect the variability in the MEP amplitude, especially in the PER recordings when the applied TES strength was 98.2 mA. The number of fluctuations in the MEP parameters was closely related to the number of warnings from the neurophysiologist during the transpedicular screw implantation, corrective rod implantation, and distraction, derotation, and compression procedures, and it was higher in the “Surgeon–neurophysiologist” IONM group. The average duration of surgery was shorter by approximately one hour in the “Real-time” IONM group. The number of two-way communications between the surgeon and the neurophysiologist and vice versa in the “Real-time” IONM group decreased by approximately half. Conclusions: This study proves the superiority of using “Real-time” IONM over the standard “Surgeon–neurophysiologist” IONM procedure in increasing the safety and non-invasiveness, shortening the time, and lowering the costs of the surgical treatment of IS patients. The modifications of the MEP nerve-conduction-recording technology with surface electrodes from nerves enable precise and reliable information on the pediatric patient’s neurological condition at every stage of the applied surgical procedures, even under conditions of slight fluctuations in anesthesia.

Verified
Journal Article
Open access
PDF file
Pawel GrabalaPawel Grabala
Pawel Grabala
Munish C GuptaMunish C Gupta
Munish C Gupta
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
Michał LatalskiMichał Latalski
Michał Latalski
Anna DanielewiczAnna Danielewicz
Anna Danielewicz
MGMichal Grabala
Michal Grabala
Background: The management of spinal deformities diagnosed before the age of 10 is critical due to the child’s development, skeletal system, and growth mechanism. Magnetically controlled growing rods (MCGRs) are a surgical treatment option for the growing spine. The aim of this study was to analyze the radiological findings of patients treated with MCGRs for early-onset scoliosis (EOS) of various etiologies. We hypothesized that the MCGRs could provide acceptable long-term radiographic results, such as an increase in the T1–T12 and T1–S1 height and significant overall deformity correction. Methods: We retrospectively reviewed 161 EOS patients with a combined total of 302 MCGRs inserted at five institutions between 2016 and 2022 with a mean follow-up of at least two years. The Cobb angle of the major curve (MC), thoracic kyphosis (TK), lumbar lordosis (LL), and T1–T12 and T1–S1 height measurements were assessed before, after, and during the follow-up. Results: Among the 90 female and 71 male patients, there were 51 neurological, 42 syndromic, 58 idiopathic, and ten congenital scoliosis etiologies. Of the patients, 73 were aged under six years old. The mean follow-up time was 32.8 months. The mean age at placement of the MCGRs was 7 years and that at the last follow-up after fusion surgery was 14.5 years. The mean MC before the initial surgery was 86.2°; following rod implantation, it was 46.9°, and at the last follow-up visit, it was 45.8°. The mean correction rate among the etiology subgroups was from 43% to 50% at follow-up. The mean TK was noted as 47.2° before MCGR implantation, 47.1° after MCGR placement, and 44.5° at the last follow-up visit. The mean T1–T12 height increased by 5.95 mm per year, with a mean T1–S1 height of 10.1 mm per year. Conclusions: MCGR treatment allowed for an average correction of the curvature by 50% during the period of lengthening, while controlling any deformity and growth of the spine, with a significant increase in the T1–T12 and T1–S1 values during the observation period. MCGR treatment in EOS carries a risk of complications. While congenital and syndromic EOS often have short and less flexible curves in those groups of patients, single rods can be as effective and safe. Definitive fusion results in the mean final coronal correction between the start of MCGR treatment and after undergoing PSF of approximately 70%. The mean T1–T12 spinal height increased by 75 mm, while the T1–S1 spinal height gained a mean of 97 mm.

8 March 2023 in Rheumatology
Verified
Journal Article
Open access
PDPrzemysław Daroszewski
Przemysław Daroszewski
AGAnna Garasz
Anna Garasz
Juliusz HuberJuliusz Huber
Juliusz Huber
KKKatarzyna Kaczmarek
Katarzyna Kaczmarek
PJPiotr Janusz
Piotr Janusz
TKTomasz Kotwicki
Tomasz Kotwicki
Introduction: Motor evoked potentials (MEPs) are currently considered as a more useful method for neurophysi-ological intraoperative monitoring than somatosensory evoked potentials in cases of surgery applied to patients with adolescent idiopathic scoliosis. The non-invasive approach is preferred to modify MEP recordings, criticizing, in many cases, the fundamentalism for neurophysiological monitoring based only on needle recordings. The aim of the review is to provide our own experience and prac-tical guidelines with reference to neuromonitoring innovations.Material and Methods: Recordings of MEPs with surface electrodes instead of needle electrodes including nerve instead of muscle combinations during neurophysiological monitoring associated with surgical interventions to the spine have become more relevant for pediatric purposes, avoiding the anesthesiology-related influences. Observations on 280 patients with Lenke A–C types of spine curvature are presented before and after the surgical correction.Results: The MEPs recorded from nerves do not undergo fluctuations at different stages of scoliosis correc-tions and the anesthesia effect more than MEPs recorded from muscles. The use of non-invasive surface electrodes during neuromonitoring for MEP recordings shortens the total time of the surgical procedure without diminishing the precision of the neural transmission evaluation. The quality of MEP recordings during intraoperative neuromonitoring from muscles can be significantly influ-enced by the depth of anesthesia or administration of muscle relaxants but not those recorded from nerves.Conclusions: The proposed definition of “real-time” neuromonitoring comprises the immediate warning from a neurophysiologist about the changes in a patient’s neurological status during scoliosis surgery (es-pecially during pedicle screws’ implantation, corrective rods’ implantation, correction, distraction and derotation of the spine curvature) exactly during the successive steps of corrective procedures. This is possible due to the simultaneous observation of MEP recordings and a camera image of the surgical field. This procedure clearly increases safety and limits financial claims resulting from possible complications.

30 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PDPrzemysław Daroszewski
Przemysław Daroszewski
Juliusz HuberJuliusz Huber
Juliusz Huber
KKKatarzyna Kaczmarek
Katarzyna Kaczmarek
PJPiotr Janusz
Piotr Janusz
GPGlowka Pawel
Glowka Pawel
TKTomasz Kotwicki
Tomasz Kotwicki
The relationships between the results of pre- and intraoperative motor evoked potential recordings during neuromonitoring and whether idiopathic scoliosis (IS) surgical correction improves the spinal efferent transmission have not been specified in detail. This study aims to compare the results of surface-recorded electromyography (EMG), electroneurography (ENG, M, and F-waves), and especially motor evoked potential (MEP) recordings from tibialis anterior muscle (TA) bilaterally in 353 girls with right idiopathic scoliosis (types 1–3 according to Lenke classification). It has not yet been documented whether the results of MEP recordings induced by transcranial single magnetic stimulus (TMS, pre- and postoperatively) and trains of electrical stimuli (TES; intraoperatively in T0—before surgery, T1—after pedicle screws implantation, and T2—after scoliosis curvature distraction and derotation following two-rod implantation) can be compared for diagnostic verification of the improvement of spinal cord neural transmission. We attempted to determine whether the constant level of optimal anesthesia during certain surgical steps of scoliosis treatment affects the parameters of MEPs recorded during neuromonitoring procedures. No neurological deficits have been observed postoperatively. The values of amplitudes but not latencies in MEP recordings evoked with TMS in IS patients compared before and after surgery indicated a slight improvement in efferent neural transmission. The results of all neurophysiological studies in IS patients were significantly asymmetrical and recorded worse on the concave side, suggesting greater neurological motor deficits at p = 0.04. The surgeries brought significant improvement (p = 0.04) in the parameters of amplitudes of sEMG recordings; however, the consequences of abnormalities in the activity of TA motor units were still reflected. ENG study results showed the symptoms of the axonal-type injury in peroneal motor fibers improving only on the concave side at p = 0.04, in parallel with F-wave parameters, which suggests that derotation and distraction might result in restoring the proper relations of the lumbar ventral roots in the spinal central canal, resembling their decompression. There were no significant differences detected in the amplitudes or latencies of MEPs induced with TMS or TES when comparing the parameters recorded preoperatively and intraoperatively in T0. The amplitudes of TES-evoked MEPs increased gradually at p = 0.04 in the subsequent periods (T1 and T2) of observation. A reduction in MEP latency at p = 0.05 was observed only at the end of the IS surgery. Studies on the possible connections between the level of anesthesia fluctuations and the required TMS stimulus strength, as well as the MEP amplitude changes measured in T0–T2, revealed a lack of relationships. These might not be the factors influencing the efferent transmission in spinal pathways beside the surgical procedures. Pre- (TMS-evoked) and intraoperative (TES-evoked) recordings are reliable for evaluating the patient’s neurological status before and during surgical scoliosis correction procedures. An increase in MEP amplitude parameters recorded on both sides after scoliosis surgery proves the immediate improvement of the total efferent spinal cord transmission. Considering comparative pre- and postoperative sEMG and ENG recordings, it can be concluded that surgeries might directly result in additional lumbar ventral root decompression. We can conclude that MEP parameter changes are determined by the surgery procedures during neuromonitoring, not the anesthesia conditions if they are kept stable, which influences a decrease in the number of false-positive neuromonitoring warnings.

Verified
Journal Article
Open access
PDF file
GPGlowka Pawel
Glowka Pawel
Pawel GrabalaPawel Grabala
Pawel Grabala
Munish C GuptaMunish C Gupta
Munish C Gupta
Daniel Enrique PereiraDaniel Enrique Pereira
Daniel Enrique Pereira
Michał LatalskiMichał Latalski
Michał Latalski
TKTomasz Kotwicki
Tomasz Kotwicki
Background: Early-onset scoliosis (EOS) refers to spinal deformities that develop and are diagnosed before the age of 10. The most important goals of the surgical treatment of EOS are to stop the progression of curvature, achieve the best possible correction, preserve motion, and facilitate spinal growth. The objectives of this multicenter study were to analyze the risk of complications among patients with EOS treated using magnetically controlled growing rods (MCGRs) and assess the patients’ and their parents’ quality of life after diagnosis and treatment with a minimum two-year follow-up. Methods: Patients given an ineffective nonoperative treatment qualified for surgery with MCGRs. This study involved 161 patients (90 females and 71 males) who were classified according to the etiology of curvature. The intraoperative and postoperative complications and those that occurred during the continuation of treatment with MCGRs were recorded and analyzed. The 24-item Early-Onset Scoliosis Questionnaire (EOSQ-24) was used to evaluate the patients’ quality of life and satisfaction with the treatment. Results: Implant-related complications requiring instrumentation revision were recorded in 26% of the patients. Medical complications occurred in 45% of the population. The EOSQ-24 revealed a significant improvement in the average scores during the follow-up. Conclusions: The treatment of early-onset scoliosis with MCGRs carries 66% risks of incurring medical and mechanical complications, the latter 26% of patients requiring revision procedures. Children with neuromuscular scoliosis, females, and with curvature greater than 90 degrees are at a higher risk of developing complications. Limiting the number of elective surgeries necessitated to prolong the instrumentation and treatment process for patients with MCGRs can greatly enhance their quality of life and satisfaction throughout the follow-up period.

7 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
PDPrzemysław Daroszewski
Przemysław Daroszewski
Juliusz HuberJuliusz Huber
Juliusz Huber
KKKatarzyna Kaczmarek
Katarzyna Kaczmarek
PJPiotr Janusz
Piotr Janusz
GPGlowka Pawel
Glowka Pawel
TKTomasz Kotwicki
Tomasz Kotwicki
Neuromonitoring of the efferent nerve impulses transmission in the spinal cord tracts during surgical scoliosis treatment makes it possible to assess whether the functional status is deteriorating, affecting the procedure's safety. Is there any relationship between pre- and intraoperative motor evoked potentials recordings and does idiopathic scoliosis (IS) surgical correction improve directly the spinal efferent transmission? This study aimed to compare the results of surface recorded electromyography (EMG), electroneurography (ENG, M and F-waves), and especially motor evoked potentials (MEP) from tibialis anterior (TA) muscle bilaterally in 353 girls with the right idiopathic scoliosis (types 1A-4C according to Lenke classification). It has not yet been documented whether the results of MEPs recordings induced by transcranial single magnetic stimulus (TMS, pre – and postoperatively) and trains of electrical stimuli (TES; intraoperatively in T0-before surgery, T1 – after pedicle screws implantation, T2 – after scoliosis curvature distraction and derotation following two rods implantation) can be compared for diagnostic verification of improvement of the spinal neural transmission. The study also attempted to determine whether the constant level of optimal anesthesia during the certain surgical steps of scoliosis treatment affects the parameters of MEPs recorded during neuromonitoring procedures. No neurological deficits have been observed postoperatively. Values of amplitudes but not latencies in MEPs recordings evoked with TMS in IS patients compared before and after surgery indicated a slight improvement in the efferent transmission of neural impulses within the fibers of the spinal tracts postoperatively. Results of all neurophysiological studies in IS patients were significantly asymmetrical and recorded worse on the concave side, suggesting greater neurological motor deficits at p=0.04. This asymmetry had been significantly reduced following IS surgery. The surgeries in IS patients brought significant improvement (p=0.04) in parameters of amplitudes of sEMG recordings, however reflecting still the consequences of the neurogenic injury of TA muscle motor units. ENG studies results indicated the symptoms of the axonal type injury in peroneal motor fibers improved only on the concave side at p=0.04 in parallel with the significant improvement of F-waves parameters, which suggests that surgeries might result in the lumbar ventral roots decompression. There were not detected significant differences in amplitudes or latencies of MEPs induced with TMS or TES comparing the parameters recorded preoperatively (one day before surgery) and intraoperatively in T0. The amplitudes of TES evoked MEPs increased gradually at p=0.04 in the subsequent periods (T1 and T2) of observation. The significant reduction of MEPs latency at p=0.05 was observed only at the end of the IS surgery. Studies on the possible connections between the level of anesthesia fluctuations and the required TMS stimulus strength, as well as the MEPs amplitude changes measured in T0-T2 revealed lack of relationships. It is not likely that they could be the factors influencing the efferent transmission in spinal pathways beside the surgical procedures. Considering that MEPs amplitude parameter reflects the number of axons excited from the motor cortex and transmitting the efferent impulses via spinal descending tracts in the white matter, pre- (TMS evoked) and intraoperative (TES evoked) recordings are reliable for evaluating the patient’s neurological status before and during surgical scoliosis correction procedures. The results of this study indicate an agreement between preoperative and early-intraoperative evaluations with these both diagnostic methods. An increase of MEPs amplitude parameters recorded on both sides after scoliosis surgery proves immediate improvement of the total efferent spinal cord transmission. Considering comparative pre- and postoperative sEMG and ENG recordings it can be concluded that surgeries might directly result in the additional lumbar ventral roots decompression. Our results of the tests on the possible variability of the anesthesia level on the parameters of intraoperative recorded MEPs show no clear relationships. We can conclude that MEPs parameters changes are determined by the surgery procedures during neuromonitoring, not the anesthesia conditions if they are kept stable, which influences a decrease in the number of false-positive neuromonitoring warnings. Further studies on a larger population of patients with long-lasting observation postoperatively are required to confirm the presented conclusions on the direct influences of scoliosis surgery on improvement of the motor function in patients with IS.