Matthew L. Magnuson

Dr. Matthew L. Magnuson


Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2005 in Environmental Science & Technology
Verified
Journal Article
Closed access
MMMatthew L. Magnuson
Matthew L. Magnuson
TSThomas F. Speth
Thomas F. Speth


29 October 2002 in Environmental Science & Technology
Verified
Journal Article
Closed access
MMMatthew L. Magnuson
Matthew L. Magnuson
CKCatherine A. Kelty
Catherine A. Kelty
CSCharles M. Sharpless
Charles M. Sharpless
KLKarl Linden
Karl Linden
WFWilliam Fromme
William Fromme
RKRamesh Kashinkunti
Ramesh Kashinkunti


1 November 2000 in Applied and Environmental Microbiology
Verified
Journal Article
Closed access
PDF file
MMMatthew L. Magnuson
Matthew L. Magnuson
JOJames H. Owens
James H. Owens
CKCatherine A. Kelty
Catherine A. Kelty
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) was used to investigate whole and freeze-thawed Cryptosporidium parvum oocysts. Whole oocysts revealed some mass spectral features. Reproducible patterns of spectral markers and increased sensitivity were obtained after the oocysts were lysed with a freeze-thaw procedure. Spectral-marker patterns for C. parvum were distinguishable from those obtained for Cryptosporidium muris . One spectral marker appears specific for the genus, while others appear specific at the species level. Three different C. parvum lots were investigated, and similar spectral markers were observed in each. Disinfection of the oocysts reduced and/or eliminated the patterns of spectral markers.

1 January 1999 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
EUEdward T. Urbansky
Edward T. Urbansky
MMMatthew L. Magnuson
Matthew L. Magnuson
DFDavid Freeman
David Freeman
CJChristopher Jelks
Christopher Jelks
Quantitation of trace levels of perchlorate ion in water has become a key issue since this species was discovered in water supplies around the United States. Although ion chromatographic methods presently offer the lowest limit of detection, ≈40 nM (4 ng ml–1), chromatographic retention times are not considered to be unique identifiers and often cannot be used in legal proceedings without confirmatory testing. Mass spectrometry can provide such confirmation; however, detection capabilities can impose a practical limitation on its use. Moreover, quadrupole mass spectrometers cannot provide sufficient accuracy and precision in m/z to identify conclusively an ion as perchlorate when samples are run directly without prior chromatographic or electrophoretic separation. We report on the abilities of (1) tetralkylammonium cations and (2) minimally nucleophilic, sterically hindered organic bases to increase selectivity in the electrospray ionization mass spectrometric (ESI-MS) determination of perchlorate ion without concomitant loss of sensitivity. Selectivity arises from the formation of a stable association complex between a base molecule and a perchlorate anion. The best results were obtained using 10 µM chlorhexidine in methanolic solution; the lower limit of detection (LLOD) for S/N ≥ 2 was less than or equal to 0.10 µM (10 ng ml–1). This compares favorably with the LLOD determined for perchlorate in the absence of any complexing agents (≈0.05 µM = 5 ng ml–1). For the other bases, which were diazabicyclo compounds (DBN, DBU, DBO), sensitivity was lower by 90% or more. The chlorhexidine–perchlorate complex (m/z = 605) can be observed even in the presence of equiformal nitrate, nitrite, hydrogensulfate, chloride, bromide, bromate, and chlorate (all together) down to approximately 1 µM; thus, the method is rugged enough to find application to systems containing multiple inorganic anions.