Arwed Elias Michael

Arwed Elias Michael


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MWMatthias Michael Woeltjen
Matthias Michael Woeltjen
JNJulius Henning Niehoff
Julius Henning Niehoff
AMArwed Elias Michael
Arwed Elias Michael
SHSebastian Horstmeier
Sebastian Horstmeier
CMChristoph Mönninghoff
Christoph Mönninghoff
JKJan Robert Kröger
Jan Robert Kröger
This study aims to investigate the qualitative and quantitative image quality of low-dose high-resolution (LD-HR) lung CT scans acquired with the first clinical approved photon counting CT (PCCT) scanner. Furthermore, the radiation dose used by the PCCT is compared to a conventional CT scanner with an energy-integrating detector system (EID-CT). Twenty-nine patients who underwent a LD-HR chest CT scan with dual-source PCCT and had previously undergone a LD-HR chest CT with a standard EID-CT scanner were retrospectively included in this study. Images of the whole lung as well as enlarged image sections displaying a specific finding (lesion) were evaluated in terms of overall image quality, image sharpness and image noise by three senior radiologists using a 5-point Likert scale. The PCCT images were reconstructed with and without a quantum iterative reconstruction algorithm (PCCT QIR+/−). Noise and signal-to-noise (SNR) were measured and the effective radiation dose was calculated. Overall, image quality and image sharpness were rated best in PCCT (QIR+) images. A significant difference was seen particularly in image sections of PCCT (QIR+) images compared to EID-CT images (p < 0.005). Image noise of PCCT (QIR+) images was significantly lower compared to EID-CT images in image sections (p = 0.005). In contrast, noise was lowest on EID-CT images (p < 0.001). The PCCT used significantly less radiation dose compared to the EID-CT (p < 0.001). In conclusion, LD-HR PCCT scans of the lung provide better image quality while using significantly less radiation dose compared to EID-CT scans.

1 March 2024 in Radiology
Verified
Journal Article
Closed access
NHNina Pauline Haag
Nina Pauline Haag
AMArwed Elias Michael
Arwed Elias Michael
SLSimon Lennartz
Simon Lennartz
CPChristoph Panknin
Christoph Panknin
JNJulius Henning Niehoff
Julius Henning Niehoff
JKJan Robert Kröger
Jan Robert Kröger
Agatston scores for coronary artery disease derived from true noncontrast and photon-counting CT angiography virtual noncontrast images (PureCalcium algorithm) showed excellent correlation but limi... Background Coronary artery calcium scoring (CACS) for coronary artery disease requires true noncontrast (TNC) CT alongside contrast-enhanced coronary CT angiography (CCTA). Photon-counting CT provi...

21 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
AMArwed Elias Michael
Arwed Elias Michael
JBJan Boriesosdick
Jan Boriesosdick
DSDenise Schönbeck
Denise Schönbeck
MWMatthias Michael Woeltjen
Matthias Michael Woeltjen
SSSaher Saeed
Saher Saeed
JNJulius Henning Niehoff
Julius Henning Niehoff
In 2021, the first clinical photon-counting CT (PCCT) was introduced. The purpose of this study is to evaluate the image quality of polyenergetic and virtual monoenergetic reconstructions in unenhanced PCCTs of the head. A total of 49 consecutive patients with unenhanced PCCTs of the head were retrospectively included. The signals ± standard deviations of the gray and white matter were measured at three different locations in axial slices, and a measure of the artifacts below the cranial calvaria and in the posterior fossa between the petrous bones was also obtained. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated for all reconstructions. In terms of the SNRs and CNRs, the polyenergetic reconstruction is superior to all virtual monoenergetic reconstructions (p < 0.001). In the MERs, the highest SNR is found in the 70 keV MER, and the highest CNR is in the 65 keV MER. In terms of artifacts below the cranial calvaria and in the posterior fossa, certain MERs are superior to polyenergetic reconstruction (p < 0.001). The PCCT provided excellent image contrast and low-noise profiles for the differentiation of the grey and white matter. Only the artifacts below the calvarium and in the posterior fossa still underperform, which is attributable to the lack of an artifact reduction algorithm in image postprocessing. It is conceivable that the usual improvements in image postprocessing, especially with regard to glaring artifacts, will lead to further improvements in image quality.

24 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
AMArwed Elias Michael
Arwed Elias Michael
JBJan Boriesosdick
Jan Boriesosdick
DSDenise Schönbeck
Denise Schönbeck
ILIngo Lopez-Schmidt
Ingo Lopez-Schmidt
JKJan Robert Kröger
Jan Robert Kröger
JNJulius Henning Niehoff
Julius Henning Niehoff
Background: The purpose of the present study was the evaluation of the image quality of polyenergetic and monoenergetic reconstructions (PERs and MERs) of CT angiographies (CTAs) of the head and neck acquired with the novel photon counting CT (PCCT) method in clinical routine. Methods: Thirty-seven patients were enrolled in this retrospective study. Quantitative image parameters of the extracranial, intracranial and cerebral arteries were evaluated for the PER and MER (40–120 keV). Additionally, two radiologists rated the perceived image quality. Results: The mean CTDIvol used in the PCCT was 8.31 ± 1.19 mGy. The highest signal within the vessels was detected in the 40 keV MER, whereas the lowest noise was detected in the 115 keV MER. The most favorable contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were detected in the PER and low keV MER. In the qualitative image analysis, the PER was superior to the MER in all rated criteria. For MER, 60–65 keV was rated as best image quality. Conclusion: Overall, PCCT offers excellent image quality for CTAs of the head and neck. At the current state, the PER of the PCCT seems to be the most favorable reconstruction for diagnostic reporting.

23 June 2022 in Tomography
Verified
Journal Article
Open access
PDF file
JNJulius Henning Niehoff
Julius Henning Niehoff
ACAlexandra Fiona Carmichael
Alexandra Fiona Carmichael
MWMatthias Michael Woeltjen
Matthias Michael Woeltjen
JBJan Boriesosdick
Jan Boriesosdick
ISIngo Lopez Schmidt
Ingo Lopez Schmidt
JKJan Robert Kröger
Jan Robert Kröger
The purpose of this study was the evaluation of image quality and radiation dose parameters of the novel photon counting CT (PCCT, Naeotom Alpha, Siemens Healthineers) using low-dose scan protocols for the detection of urolithiasis. Standard CT scans were used as a reference (S40, Somatom Sensation 40, Siemens Healthineers). Sixty-three patients, who underwent CT scans between August and December 2021, were retrospectively enrolled. Thirty-one patients were examined with the PCCT and 32 patients were examined with the S40. Radiation dose parameters, as well as quantitative and qualitative image parameters, were analyzed. The presence of urolithiasis, image quality, and diagnostic certainty were rated on a 5-point-scale by 3 blinded readers. Both patient groups (PCCT and S40) did not differ significantly in terms of body mass index. Radiation dose was significantly lower for examinations with the PCCT compared to the S40 (2.4 ± 1.0 mSv vs. 3.4 ± 1.0 mSv; p < 0.001). The SNR was significantly better on images acquired with the PCCT (13.3 ± 3.3 vs. 8.2 ± 1.9; p < 0.001). The image quality of the PCCT was rated significantly better (4.3 ± 0.7 vs. 2.8 ± 0.6; p < 0.001). The detection rate of kidney or ureter calculi was excellent with both CT scanners (PCCT 97.8% and S40 99%, p = 0.611). In high contrast imaging, such as the depiction of stones of the kidney and the ureter, PCCT allows a significant reduction of radiation dose, while maintaining excellent diagnostic confidence and image quality. Given this image quality with our current protocol, further adjustments towards ultra-low-dose CT scans appear feasible.

17 August 2023 in Clinical Neuroradiology
Verified
Journal Article
Open access
PDF file
AMArwed Elias Michael
Arwed Elias Michael
DSDenise Schoenbeck
Denise Schoenbeck
MWMatthias Michael Woeltjen
Matthias Michael Woeltjen
JBJan Boriesosdick
Jan Boriesosdick
JKJan Robert Kroeger
Jan Robert Kroeger
JBJan Borggrefe
Jan Borggrefe
Purpose: Nonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application. Methods: A total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists. Results: In most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best. Conclusion: In nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).