Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.
Ultrasonic testing (UT) has been widely used for the Nondestructive Evaluation (NDE) of pipes due to its many favorable characteristics. However, one of the main challenges in the general use of UT for real-world pipelines is the sensitivity of this method to environmental and operational condition changes. This paper proposes a new UT method with enhanced compensation for environmental effects and operational condition changes. In particular, the effectiveness of the new method is tested in the presence of temperature variations, and changes in water flow rate inside a stainless-steel pipe. The proposed UT method uses multi-mode and broadband guided ultrasonic waves in the pipe walls, excited and received by single-element ultrasonic sensors that are spatially separated, forming a measurement zone between any pair of such transmit and receive sensors. Amplitude changes, time shifts, and frequency content variations in the ultrasonic signal due to temperature changes and water flow are evaluated and compensated for reliable UT of mechanical changes in the pipe. It is observed that spurious effects of water flow on ultrasonic response, if not properly compensated, can dominate over effects due to actual mechanical changes, but such liquid-boundary effects can be compensated effectively by the proposed time- and frequency-filtering method.