Siddhartha Singh

Dr. Siddhartha Singh

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2022 in MAUSAM
Verified
Journal Article
Open access
PDF file
PSPriyanka Sinha
Priyanka Sinha
SSSiddhartha Singh
Siddhartha Singh
PSPooja Saroj
Pooja Saroj
In the present study, continuous measurements of Surface Ozone (O3), Oxides of Nitrogen (NOx (NO+ NO2)), and carbon monoxide (CO), monitored at five different locations in Delhi National Capital Region have been studied for the period 2013 – 2019. The five monitoring locations used are namely IMD Lodi Road, IGI Airport Palam, CV Raman Dheerpur, CRRI Mathura Road, and NCMRWF Noida. The average hourly concentration of O3, NO, NO2, CO, NOx (NO + NO2), and OX(NO2 +O3) are found in the range of 32.44 ppb to 36.57 ppb, 19.46 to 28.09 ppb, 20.83 to 26.89 ppb,1.67 to 1.89 ppm,43.04 to 54.99 ppb, and 54.06 to 60.99 ppb respectively during the study period. Diurnal variation of NOx and CO Concentrations show higher values during the morning (0600-0900h) and late evening (1900-2400h) hours while the highest concentrations of ozone have been observed during afternoon hours. The relationship between NO, NO2, and surface O3 as a function of NOx has also been examined during daylight hours (0500hrs IST to 1900 hrs IST) and chemical coupling of the three species i.e. NO, NO2 and O3 have been studied. The ground-level concentration of Ozone has been found to decrease with increasing NOx concentration during the daytime. The variations in concentrations of oxidants (NO2 + O3) with the concentration of [NOx] have been studied to examine the contributing pollution sources of oxidants at all the study sites. The average rate of change of O3 concentrations (dO3/dt) has been examined at all five locations. The monthly and diurnal variation of oxidants [OX] at all the study locations has shown a strong positive correlation with temperature whereas a negative correlation with humidity.

1 April 2013 in MAUSAM
Verified
Journal Article
Open access
PDF file
SPSunil Peshin
Sunil Peshin
SSSiddhartha Singh
Siddhartha Singh
Ok;q foKku os/k’kkyk] lqdqck] tkiku esa 6 ekpZ ls 24 ekpZ 2006 rd MkWclu vkstksu LisDVªksa QksVks ehVj ijLij rqyuk djus ds fy, ,d MCY;w-,e-vks-@th-,-MCY;w- vfHk;ku pyk;k x;kA bl ijLij rqyukRed vfHk;ku ds nkSjku Hkkjrh; ekud MkWclu vkst+ksu LisDVªksQksVksehVj la[;k 112 dh rqyuk {ks=h; ekud MkWclu vkstksu LisDVªksQksVksehVj la[;k 116 ds lkFk dh xbZA bu rqyukvksa ls bl ckr dh iqf"V gqbZ gS fd Hkkjrh; MkWCklu vkstksu LisDVªksQksVksehVj la[;k 112 va’kkdu dh lgh fLFkfr esa Fkk vkSj midj.k ls izkIr vk¡dM+sa lgh FksA 36 ds lkFk 112 ls izkir ifj.kke Hkh ,d nwljs ls lgh esy [kk jgs gSaA The WMO/GAW campaign for inter-comparison of Dobson Ozone Spectrophotometer was held from 6 to 24 March 2006 at the Aerological Observatory, Tsukuba, Japan. During the inter-comparison campaign, the Indian standard Dobson Ozone Spectrophotometer no.112 was compared with the regional standard Dobson Ozone Spectrophotometer no.116. The comparisons confirmed that the Indian standard Dobson Ozone Spectrophotometer no.112 was in good state of calibration and the data derived from the instrument was reliable. The results of 112 with 36 are also in good agreement with each other.

10 July 2013
Verified
Book Chapter
Closed access
PDF file
SSSiddhartha Singh
Siddhartha Singh
SPS. K. Peshin
S. K. Peshin

26 June 2025 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
LRLatha Radhadevi
Latha Radhadevi
MBMurthy Bandaru
Murthy Bandaru
YYYesobu Yarragunta
Yesobu Yarragunta
GBGufran Beig
Gufran Beig
ARAditi Rathod
Aditi Rathod
SSSiddhartha Singh
Siddhartha Singh

2 September 2021 in Research Square
Verified
Preprint
Open access
PDF file
PSPriyanka Sinha
Priyanka Sinha
SSSiddhartha Singh
Siddhartha Singh
PSPooja Saroj
Pooja Saroj
GBGufran Beig
Gufran Beig
BMB. S. Murthy
B. S. Murthy
In the present study, continuous measurements of Surface Ozone (O3), Oxides of Nitrogen (NOx (NO + NO2)), and carbon monoxide (CO), monitored at five different locations in Delhi National Capital Region have been studied for the period 2013–2019. The five monitoring locations used are namely IMD Lodi Road, IGI Airport Palam, CV Raman Dheerpur, CRRI Mathura Road, and NCMRWF Noida. The average hourly concentration of O3, NO, NO2, CO, NOx (NO + NO2), and OX(NO2 + O3) are found in the range of 32.44 ppb to 36.57 ppb, 19.46 to 28.09 ppb, 20.83 to 26.89 ppb,1.67 to 1.89 ppm,43.04 to 54.99 ppb, and 54.06 to 60.99 ppb respectively during the study period. Diurnal variation of NOx and CO Concentrations show higher values during the morning (0600-0900h) and late evening (1900-2400h) hours while the highest concentrations of ozone have been observed during afternoon hours. The relationship between NO, NO2, and surface O3 as a function of NOx has also been examined during daylight hours (0500hrs IST to 1900 hrs IST) and chemical coupling of the three species i.e. NO, NO2 and O3 have been studied. The ground-level concentration of Ozone have been found to decrease with increasing NOx concentration during daytime. The variations in concentrations of oxidants (NO2 + O3) with the concentration of [NOx] have been studied to examine the contributing pollution sources of oxidants at all the study sites. The average rate of change of O3 concentrations (dO3/dt) has been examined at all five locations. The monthly and diurnal variation of oxidants [OX] at all the study locations has shown a strong positive correlation with temperature whereas a negative correlation with humidity.