Abdulrahman M. Alfuraih

Dr. Abdulrahman M. Alfuraih

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2019 in Aging Clinical and Experimental Research
Verified
Journal Article
Open access
PDF file
AAAbdulrahman M. Alfuraih
Abdulrahman M. Alfuraih
ATAi Lyn Tan
Ai Lyn Tan
POPhilip O’cOnnor
Philip O’cOnnor
PEPaul Emery
Paul Emery
RWRichard J. Wakefield
Richard J. Wakefield
Skeletal muscle undergoes structural changes with ageing which may alter its biomechanical properties. Shear wave elastography (SWE) may detect these changes by measuring muscle stiffness.

9 October 2017 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
PDF file
AAAbdulrahman M. Alfuraih
Abdulrahman M. Alfuraih
POPhilip O'Connor
Philip O'Connor
EHElizabeth Hensor
Elizabeth Hensor
ATAi Lyn Tan
Ai Lyn Tan
PEPaul Emery
Paul Emery
RWRichard J. Wakefield
Richard J. Wakefield

27 February 2019 in Skeletal Radiology
Verified
Journal Article
Open access
PDF file
AAAbdulrahman M. Alfuraih
Abdulrahman M. Alfuraih
POPhilip O’cOnnor
Philip O’cOnnor
ATAi Lyn Tan
Ai Lyn Tan
EHElizabeth M. A. Hensor
Elizabeth M. A. Hensor
ALAndreas Ladas
Andreas Ladas
RWRichard J. Wakefield
Richard J. Wakefield
Objective To investigate muscle stiffness in patients with idiopathic inflammatory myopathies (IIM) using shear wave elastography (SWE) and to correlate the results with muscle strength and MRI features of myositis. Materials and methods Muscle shear wave velocity (SWV) was measured in 23 active IIM patients (13 females, mean age 50.4 ± 16.1 years) and 23 matched healthy controls (13 females, mean age 50.7 ± 16.2 years). The investigated muscles included the vastus lateralis (VL), rectus femoris (RF), vastus medialis (VM) vastus intermedius (VI), biceps femoris (BF), semitendinosus (ST), semimembranosus (SM) and the biceps brachii (BB) scanned during relaxed resting and passive stretching positions. Participants performed multiple tests to evaluate their muscle strength. IIM patients had a thigh MRI to assess degrees of oedema, fatty infiltration and atrophy. Results In the resting position, IIM patients had a 12.9–22.2% significantly lower SWV (p < 0.05) for the quadriceps and hamstrings, but not BB. There was no difference during passive stretching. The SWV for VL, VI and BF showed moderate correlations with the muscle strength tests ranging from r = 0.47 to r = 0.70 (all p < 0.05). Lower SWV was associated with greater MRI scores of oedema (p = 0.001) and atrophy (p = 0.006). However, SWV did not correlate with fatty infiltration (r < 0.3; p = 0.28), creatine kinase (r = 0.28; p = 0.19) or disease duration (r = 0.26; p = 0.24). Conclusion Shear wave elastography may detect abnormal reduced thigh stiffness in IIM patients. SWE measurements were significantly associated with muscle weakness and MRI signs of oedema and atrophy. Future research should investigate this new technology for monitoring disease activity.

29 November 2017 in Medical Ultrasonography
Verified
Journal Article
Open access
PDF file
AAAbdulrahman M. Alfuraih
Abdulrahman M. Alfuraih
POPhilip O'Connor
Philip O'Connor
ATAi Lyn Tan
Ai Lyn Tan
EHElizabeth Hensor
Elizabeth Hensor
PEPaul Emery
Paul Emery
RWRichard J. Wakefield
Richard J. Wakefield
Aims: The reliability and agreement between shear wave elastography (SWE) systems using different acquisition methods in muscles is not yet established. The objectives were to determine the reliability of a new SWE system on normal resting muscles using different acquisition methods and to compare its performance to an established state-of-the-art system.Material and methods: Small, medium and large ROI sizes in addition to longitudinal, oblique and transverse orientations over five different locations within the rectus femoris muscle were tested using the new system. Results were compared to the established system to test for inter-system reproducibility.Results: Lowest within-subject coefficient of variance (4.3%) andshear wave velocity (1.83 m/s) were associated with the medium ROI and longitudinal orientation from the lateral location. This combination resulted in a strong internal agreement of intra-class correlation of 0.76 (0.57–0.89) for the new system and an almost perfect agreement of 0.92 (0.82–0.97) for the established. Inter-system reproducibility for the best combination was 0.71 (0.48–1) with a mean velocity difference ±95% limits of agreement of 0.07±0.49 m/s.Conclusions: Altering SWE acquisition methods can produce variable results. The new system produced reliable results that are comparable with but not as reliable as the established.

1 February 2019 in Radiology
Verified
Journal Article
Open access
ATAniket N. Tavare
Aniket N. Tavare
AAAbdulrahman M. Alfuraih
Abdulrahman M. Alfuraih
EHElizabeth M. A. Hensor
Elizabeth M. A. Hensor
EAEmmanouil Astrinakis
Emmanouil Astrinakis
HGHarun Gupta
Harun Gupta
PRPhilip Robinson
Philip Robinson
Shear-wave elastography helps characterize musculoskeletal soft-tissue lesions as benign or malignant over evaluation with conventional US, but not when US is combined with MRI. PurposeTo examine if shear-wave elastography (SWE) improves the accuracy of diagnosing soft-tissue masses as benign or malignant compared with US alone or in combination with MRI.Materials and MethodsTwo hundred six consecutive adult participants (mean age, 57.7 years; range, 18–91 years), including 89 men (median age, 56.0 years; range, 21–91 years) and 117 women (median age, 59.1 years; range, 18–88 years), who were referred for biopsy of a soft-tissue mass were prospectively recruited from December 2015 through March 2017. Participants underwent B-mode US, MRI, and SWE prior to biopsy. Three musculoskeletal radiologists independently reviewed US images alone, followed by US and MRI images together, and classified lesions as benign, probably benign, probably malignant, or malignant. For SWE, the area under the receiver operating characteristic (ROC) curve (AUC) was calculated for transverse shear-wave velocity (SWV). Multivariable logistic regression was used to investigate the association between SWE a...

1 January 2021 in Ultrasonography
Verified
Journal Article
Open access
PDF file
AAAbdulaziz Ibrahim Alrashed
Abdulaziz Ibrahim Alrashed
AAAbdulrahman M. Alfuraih
Abdulrahman M. Alfuraih
This study was aimed to investigate the reproducibility of shear wave elastography (SWE) among operators, machines, and probes in a phantom, and to evaluate the effect of depth of the embedded inclusions and the accuracy of the measurements. In vitro stiffness measurements were made of six inclusions (10, 40, and 60 kPa) embedded at two depths (1.5 cm and 5 cm) in an elastography phantom. Measurements were obtained by two sonographers using two ultrasound machines (the SuperSonic Imagine Aixplorer with the XC6-1, SL10-2 and SL18-5 probes, and the General Electric LOGIQ E9 with the 9L-D probe). Variability was evaluated using the coefficient of variation. Reproducibility was calculated using intraclass correlation coefficients (ICCs). For shallow inclusions, low variability was observed between operators (range, 0.9% to 5.4%). However, the variability increased significantly for deep inclusions (range, 2.4% to 80.8%). The measurement difference between the operators was 1%-15% for superficial inclusions and 3%-43% for deep inclusions. Inter-operator reproducibility was almost perfect (ICC>0.90). The measurement difference between machines was 0%-15% for superficial inclusions and 38.6%-82.9% for deep inclusions. For superficial inclusions, the reproducibility among the three probes was excellent (ICC>0.97). The mean stiffness values of the 10 kPa inclusion were overestimated by 16%, while those of the 40 kPa and 60 kPa inclusions were underestimated by 42% and 48%, respectively. Phantom SWE measurements were only reproducible among operators, machines, and probes at superficial depths. SWE measurements acquired in deep regions should not be used interchangeably among operators, machines, or probes.