Minjeong Nam

Prof. Dr. Minjeong Nam

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
MNMinjeong Nam
Minjeong Nam
SYSumi Yoon
Sumi Yoon
Mina HurMina Hur
Mina Hur
GLGUN-HYUK LEE
GUN-HYUK LEE
HKHanah Kim
Hanah Kim
HKHyeong Nyeon Kim
Hyeong Nyeon Kim
Minjeong Nam , M.D., Ph.D., Sumi Yoon , M.D., Mina Hur , M.D., Ph.D., Gun Hyuk Lee , M.D., Hanah Kim , M.D., Ph.D., Mikyoung Park , M.D., Ph.D., and Hyeong Nyeon Kim , M.D.. Ann Lab Med 2022;42:398-405. https://doi.org/10.3343/alm.2022.42.4.398

1 July 2022 in Annals of Laboratory Medicine
Verified
Journal Article
Open access
PDF file
MPMikyoung Park
Mikyoung Park
Mina HurMina Hur
Mina Hur
HKHanah Kim
Hanah Kim
CLChae Hoon Lee
Chae Hoon Lee
JLJong Ho Lee
Jong Ho Lee
MNMinjeong Nam
Minjeong Nam
Mikyoung Park , M.D., Ph.D, Mina Hur , M.D., Ph.D, Hanah Kim , M.D., Ph.D, Chae Hoon Lee , M.D., Ph.D, Jong Ho Lee , M.D., Hyung Woo Kim , M.D., and Minjeong Nam , M.D., Ph.D.. Ann Lab Med 2022;42:406-14. https://doi.org/10.3343/alm.2022.42.4.406

23 November 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SYSumi Yoon
Sumi Yoon
Mina HurMina Hur
Mina Hur
GLGUN-HYUK LEE
GUN-HYUK LEE
MNMinjeong Nam
Minjeong Nam
HKHanah Kim
Hanah Kim
Digital morphology (DM) analyzers are widely applied in clinical practice. It is necessary to evaluate performances of DM analyzers by focusing on leukopenic samples. We evaluated the analytical performance, including precision, of a Sysmex DI-60 system (Sysmex, Kobe, Japan) on white blood cell (WBC) differentials in leukopenic samples. In a total of 40 peripheral blood smears divided into four groups according to WBC count (normal, mild, moderate, and severe leukopenia; each group n = 10), we evaluated precision of WBC preclassificaiton by DI-60. %coefficients of variation (%CVs) of precision varied for each sample and for each cell class; the fewer cells per slide, the higher %CV. The overall specificity and efficiency were high for all cell classes except plasma cells (95.9–99.9% and 90.0–99.4%, respectively). The largest absolute value of mean difference between DI-60 and manual count in each group was: 10.77, normal; 10.22, mild leukopenia; 19.09, moderate leukopenia; 47.74, severe leukopenia. This is the first study that evaluated the analytical performance of DI-60 on WBC differentials in leukopenic samples as the main subject. DI-60 showed significantly different performance depending on WBC count. DM analyzers should be evaluated separately in leukopenic samples, even if the overall performance was acceptable.

31 October 2022 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Open access
PDF file
GLGUN-HYUK LEE
GUN-HYUK LEE
SYSumi Yoon
Sumi Yoon
MNMinjeong Nam
Minjeong Nam
HKHanah Kim
Hanah Kim
Mina HurMina Hur
Mina Hur
Objectives: CellaVision DC-1 (DC-1, Sysmex, Kobe, Japan) is a newly launched digital morphology analyzer that was developed mainly for small to medium-volume laboratories. We evaluated the precision, qualitative performance, comparison of cell counts between DC-1 and manual counting, and turnaround time (TAT) of DC-1. Methods: Using five peripheral blood smear (PBS) slides spanning normal white blood cell (WBC) range, precision and qualitative performance of DC-1 were evaluated according to the Clinical and Laboratory Standards Institute (CLSI) EP15-A3, EP15-Ed3-IG1, and EP12-A2 guidelines. Cell counts of DC-1 and manual counting were compared according to the CLSI EP 09C-ED3 guidelines, and TAT of DC-1 was also compared with TAT of manual counting. Results: DC-1 showed excellent precision (%CV, 0.0–3.5%), high specificity (98.9–100.0%), and high negative predictive value (98.4–100.0%) in 18 cell classes (12 WBC classes and six non-WBC classes). However, DC-1 showed 0% of positive predictive value in seven cell classes (metamyelocytes, myelocytes, promyelocytes, blasts, plasma cells, nucleated red blood cells, and unidentified). The largest absolute mean differences (%) of DC-1 vs. manual counting was 2.74. Total TAT (min:s) was comparable between DC-1 (8:55) and manual counting (8:55). Conclusions: This is the first study that comprehensively evaluated the performance of DC-1 including its TAT. DC-1 has a reliable performance that can be used in small to medium-volume laboratories for assisting PBS review. However, DC-1 may make unnecessary workload for cell verification in some cell classes.

15 January 2021 in Clinical Chemistry and Laboratory Medicine (CCLM)
Verified
Journal Article
Closed access
SYSumi Yoon
Sumi Yoon
Mina HurMina Hur
Mina Hur
MPMikyoung Park
Mikyoung Park
HKHanah Kim
Hanah Kim
SKSeung Wan Kim
Seung Wan Kim
YYYeo-Min Yun
Yeo-Min Yun
Objectives: Vision Pro (West Medica, Perchtoldsdorf, Austria) is a recently developed digital morphology analyzer. We evaluated the performance of Vision Pro on white blood cell (WBC) differentials. Methods: In a total of 200 peripheral blood smear samples (100 normal and 100 abnormal samples), WBC preclassification and reclassification by Vision Pro were evaluated and compared with manual WBC count, according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). Results: The overall sensitivity was high for normal WBCs and nRBCs (80.1–98.0%). The overall specificity and overall efficiency were high for all cell classes (98.1–100.0% and 97.7–99.9%, respectively). The absolute values of mean differences between Vision Pro and manual count ranged from 0.01 to 1.31. In leukopenic samples, those values ranged from 0.09 to 2.01. For normal WBCs, Vision Pro preclassification and manual count showed moderate or high correlations (r=0.52–0.88) except for basophils (r=0.34); after reclassification, the correlation between Vision Pro and manual count was improved (r=0.36–0.90). Conclusions: This is the first study that evaluated the performance of Vision Pro on WBC differentials. Vision Pro showed reliable analytical performance on WBC differentials with improvement after reclassification. Vision Pro could help improve laboratory workflow.

31 August 2022 in Microbiology Spectrum
Verified
Journal Article
Open access
MNMinjeong Nam
Minjeong Nam
SYSeung Gyu Yun
Seung Gyu Yun
SKSang-Wook Kim
Sang-Wook Kim
CKChris Gunwoo Kim
Chris Gunwoo Kim
JCJae Hyun Cha
Jae Hyun Cha
YCYunjung Cho
Yunjung Cho
There have been few studies that comprehensively evaluated factors affecting immune responses and the correlation between humoral and cellular immune responses after vector, mix-and-match, and mRNA vaccines against SARS-CoV-2. Therefore, we analyzed the effects of age, sex, and the different vaccine regimens on the immune responses to vaccination against SARS-CoV-2.