Vincent Leclerc

Dr. Vincent Leclerc

Assistance Publique - Hopitaux de Paris
+1
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2020 in Clinical Pharmacokinetics
Verified
Journal Article
Closed access
PDF file
HMHanen Marsit
Hanen Marsit
MPMichaël Philippe
Michaël Philippe
MNMichael Neely
Michael Neely
TRTeresa Rushing
Teresa Rushing
YBYves Bertrand
Yves Bertrand
SGSylvain Goutelle
Sylvain Goutelle

4 January 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
JHJustine Heitzmann
Justine Heitzmann
YTYann Thoma
Yann Thoma
RBRomain Bricca
Romain Bricca
MGMarie-Claude Gagnieu
Marie-Claude Gagnieu
VLVincent Leclerc
Vincent Leclerc
SGSylvain Goutelle
Sylvain Goutelle
Daptomycin is a candidate for therapeutic drug monitoring (TDM). The objectives of this work were to implement and compare two pharmacometric tools for daptomycin TDM and precision dosing. A nonparametric population PK model developed from patients with bone and joint infection was implemented into the BestDose software. A published parametric model was imported into Tucuxi. We compared the performance of the two models in a validation dataset based on mean error (ME) and mean absolute percent error (MAPE) of individual predictions, estimated exposure and predicted doses necessary to achieve daptomycin efficacy and safety PK/PD targets. The BestDose model described the data very well in the learning dataset. In the validation dataset (94 patients, 264 concentrations), 21.3% of patients were underexposed (AUC24h < 666 mg.h/L) and 31.9% of patients were overexposed (Cmin > 24.3 mg/L) on the first TDM occasion. The BestDose model performed slightly better than the model in Tucuxi (ME = −0.13 ± 5.16 vs. −1.90 ± 6.99 mg/L, p < 0.001), but overall results were in agreement between the two models. A significant proportion of patients exhibited underexposure or overexposure to daptomycin after the initial dosage, which supports TDM. The two models may be useful for model-informed precision dosing.

5 February 2018 in Drugs in R&D
Verified
Journal Article
Open access
PDF file
VLVincent Leclerc
Vincent Leclerc
MDMichel Ducher
Michel Ducher
NBNathalie Bleyzac
Nathalie Bleyzac
Background Pediatric hematopoietic stem cell transplantation (HSCT) allows the treatment of numerous diseases, both malignant and non-malignant. Cyclosporine, a narrow therapeutic index drug, is the major immunosuppressant used to prevent graft-versus-host disease (GVHD), but may also cause severe adverse effects in case of overdosing. Objective The objective of this study is to predict the initial cyclosporine residual blood concentration value after pediatric HSCT, and consequently the dose necessary to reach the therapeutic range, using a mathematical individual predictive model. Methods Clinical and biological data collected from the graft infusion for 2 months after transplantation in 155 pediatric patients undergoing HSCT between 2008 and 2016 were used to generate synthetic data for 1000 subjects which were used to build a Bayesian network model. We compared the characteristics and sensitivity to clinical or biological missing data of this model with four other methods. Results The tree-augmented Naïve Bayesian network showed the best characteristics, with no missing data (area under the curve of the receiving operator characteristics curve [AUC-ROC] of 0.89 ± 0.02), 18.9 ± 2.6% of patients misclassified, and positive and negative predictive values of 85.9 ± 3.4% and 74.2 ± 5.1%, respectively, and this trend is found in the synthetic dataset from no to 10% missing data. The most relevant variables that could influence whether the initial residual cyclosporine concentration is in the therapeutic range are the last dose before measurement and the mean dose before measurement. Conclusions We developed and cross-validated an online Bayesian network to predict the first cyclosporine concentration after pediatric HSCT. This model allows simulation of different dosing regimens, and enables the best dosing regimen to reach the therapeutic range immediately after transplantation to be found, minimizing the risk of adverse effects and GVHD occurrence.

8 June 2021 in The Journal of Clinical Pharmacology
Verified
Journal Article
Closed access
PDF file
VLVincent Leclerc
Vincent Leclerc
MDMichel Ducher
Michel Ducher
ACAntony Ceraulo
Antony Ceraulo
YBYves Bertrand
Yves Bertrand
NBNathalie Bleyzac
Nathalie Bleyzac

24 January 2010
Verified
Conference Paper
Open access
PDF file
JBJoanna Berzowska
Joanna Berzowska
MBMarc Beaulieu
Marc Beaulieu
VLVincent Leclerc
Vincent Leclerc
GOGaia Orain
Gaia Orain
CMCatherine Marchand
Catherine Marchand
MSMiliana Sesartic
Miliana Sesartic

9 June 2023 in European Journal of Hospital Pharmacy
Verified
Journal Article
Closed access
PDF file
MGMarie-Pauline Gagaille
Marie-Pauline Gagaille
VLVincent Leclerc
Vincent Leclerc
JAJeanne Allard
Jeanne Allard
FMFlorent Marty
Florent Marty
BTBleuenn Treguier
Bleuenn Treguier
NPNathalie Pons-Kerjean
Nathalie Pons-Kerjean
Objectives Anticancer drug preparation control is essential to ensure quality and patient safety. Drugcam (Eurekam Company) is a digital video-assisted control system based on artificial intelligence methods to identify vials used and volumes withdrawn. As for any control system, qualification is required before use in a chemotherapy compounding unit (CCU). Methods We conducted an operational qualification (sensitivity, specificity and accuracy assessment of vials and volumes recognition and quantitative analysis of measured volumes) and a performance qualification (comparison with visual control) of Drugcam in our CCU, as well as an impact study on compounding time and compound supply time. Results Sensitivity, specificity and accuracy of vials (94%, 98% and 96%, respectively) and volumes (86%, 96% and 91%, respectively) recognition are satisfactory. It depends on both the object presented and the camera tested. False positives, which could lead to release of non-compliant preparation, were detected. Volume reading errors may exceed the tolerance threshold of ±5% for small volumes. Drugcam did not significantly lengthen compounding time and compound supply time. Conclusions No recommendations for a qualification method of this new type of control equipment exist. However, a qualification process is essential to understand tool limitations and integrate them into the CCU risk management system. Drugcam enables anticancer drug preparation to be secure and is also useful for initial and continuous staff training.