Reperfusion of myocardial tissue is the main goal of primary percutaneous coronary intervention (PPCI) with stent implantation in the treatment of acute ST-segment elevation myocardial infarction (STEMI). Although PPCI has contributed to a dramatic reduction in cardiovascular mortality over three decades, normal myocardial perfusion is not restored in approximately one-third of these patients. Several mechanisms may contribute to myocardial reperfusion failure, in particular distal embolization of the thrombus and plaque fragments. In fact, this is a possible complication during PPCI, resulting in microvascular obstruction and no-reflow phenomenon. The presence of a visible thrombus at the time of PPCI in patients with STEMI is associated with poor procedural and clinical outcomes. Aspiration thrombectomy during PPCI has been proposed to prevent embolization in order to improve these outcomes. In fact, the most recent guidelines suggest the routine use of manual aspiration thrombectomy during PPCI (class IIa) to reduce the risk of distal embolization. Even though numerous international studies have been reported, there are conflicting results on the clinical impact of aspiration thrombectomy during PPCI. In particular, data on long-term clinical outcomes are still inconsistent. In this review, we have carefully analyzed literature data on thrombectomy during PPCI, taking into account the most recent studies and meta-analyses.
Left ventricular assist device (LVAD) obstruction can be a dramatic and life-threatening complication in patients with advanced heart failure (HF). Despite surgical redo is often required in these patients, it is associated with a high risk of periprocedural negative outcome. We report the case of a 68-year-old male with a thrombotic stenosis of the LVAD proximal outflow-graft. Following Heart Team debate, a percutaneous intervention was planned during veno-arterial Extra Corporeal Membrane Oxygenation (ECMO) assistance. To achieve the needed catheter support, we used the “distal balloon anchoring technique” through the outflow-graft and managed to implant a covered stent, rapidly restoring the flow through the LVAD. The patient was discharged without further complications. Our case shows that, in selected cases, percutaneous treatment of LVAD obstructions can be feasible, especially using advanced techniques derived from the experiences in coronary interventions and under ECMO assistance. More cases and prospective studies are mostly needed to explore long-term patency of the LVADs and clinical outcomes in these high-risk patients.
1 January 2014 in Journal of Clinical and Diagnostic Research
We are reporting a clinical case of a 78-year-old male who had oppressive chest pain at rest, which regressed with the intake of sublingual nitrates. Coronary angiography showed a chronic total occlusion (CTO) of the left anterior descending (LAD) artery, a normal circumflex, a hypoplasic right coronary artery and a Cardiac Magnetic Resonance showing vital tissue in anterior wall. During the procedure of CTO-PCI on LAD, patient developed multiple and contemporary coronary thrombosis in spite of low platelet reactivity, which was assessed by using Multiplate. A manual thrombectomy was performed with a good final result only after drug eluting stents (DES) implantation.
Drug-eluting stents (DES) have a moderately higher incidence of stent thrombosis compared to bare metal stents (BMS) and very late DES thrombosis has been frequently described. We report a case of a 66 year-old male who experienced very late stent thrombosis at 5 years after paclitaxel-eluting stent (PES) implantation and 3 days after clopidogrel withdrawal. Intravascular ultrasound (IVUS) performed during the index procedure showed that the previously implanted PES was undersized. Since the patient could not take clopidogrel, we treated him with only a noncompliant balloon (3.0 × 15 mm) with optimal expansion as confirmed by IVUS. This case report describes a patient who continued clopidogrel treatment for 5 years and was probably protected from a procedural failure. During the current hospitalization, the patient was found to be a responder to clopidogrel after a platelet function assessment with Multiplate (Dynabyte Informationssysteme GmbH, Munich, Germany).
In patients with advanced heart failure (HF), left ventricular assist devices (LVADs) have demonstrated to be effective in improving the quality of life and reducing further hospitalizations. Although uncommon, LVAD outflow graft obstruction (OGO) is a potentially life-threatening complication and percutaneous treatment has been proposed as a standard intervention strategy in such cases. We report the case of a 69 year old man admitted due to LVAD failure causing unstable HF. Past medical history included percutaneous intervention on the outflow graft with stent implantation one year before. The patient was under chronic treatment with vitamin K antagonists (VKA). Emergent percutaneous angiography was performed, showing recurrent OGO due to thrombosis located at a kinking site, distally to the previously treated segment. Using distal anchoring technique, a balloon-expandable 10 × 79 mm endoprosthesis (GORE® Viabahn® VBX) was effectively positioned and post-dilated. Final angiography confirmed the patency of the stent implanted one-year before. Despite the procedure succeeding in restoring LVAD function, the patient died due to septic shock ten days after. Our case suggests that recurrent OGO can be effectively treated with percutaneous redo and that long-term stent patency can be achieved with a standard antithrombotic treatment, despite further thrombotic events in other segments of the graft are still possible (especially at the kinking site). Moreover, other noncardiac conditions as infective complications, can dramatically impact the clinical course and lead to unfavorable outcomes.
About Me
Interventional cardiologist at the San Camillo Forlanini Hospital.
Interventional cardiologist at the San Camillo Forlanini Hospital.