To meet the high radiation challenge for detectors in future high-energy physics, a novel 3D 4H-SiC detector was investigated. Three-dimensional 4H-SiC detectors could potentially operate in a harsh radiation and room-temperature environment because of its high thermal conductivity and high atomic displacement threshold energy. Its 3D structure, which decouples the thickness and the distance between electrodes, further improves the timing performance and the radiation hardness of the detector. We developed a simulation software—RASER (RAdiation SEmiconductoR)—to simulate the time resolution of planar and 3D 4H-SiC detectors with different parameters and structures, and the reliability of the software was verified by comparing the simulated and measured time-resolution results of the same detector. The rough time resolution of the 3D 4H-SiC detector was estimated, and the simulation parameters could be used as guideline to 3D 4H-SiC detector design and optimization.
The concept of ''SU(3) analysis'' is proposed for the B(E2) anomaly based on various mechanisms reported recently. The B(E2) anomaly is analyzed in the SU(3) symmetry limit. According to the results of the analysis, the SU(3) third-order interaction can generate the level-crossing phenomenon for any mechanism, which is vital for the emergence of the B(E2) anomaly. Thus, this anomaly is found to be related with the SU(3) symmetry. The B(E2) anomaly in is also analyzed.
We investigate the exclusive $$J/\psi $$ production at the future Electron-ion collider in China by utilizing the eSTARlight event generator. We model the cross-section and kinematics by fitting to the world data of $$J/\psi $$ photoproduction. Projected statistical uncertainties on $$J/\psi $$ production are based on the design of a central detector, which consists of a tracker and vertex subsystem. The precision of the pseudo-data allows us to probe the near-threshold mechanism, e.g. the re-scattering effect. The significance of the forward amplitudes is discussed as well. The design and optimization of the detector enhance the potential for exploring the near-threshold region and the realm of high four-momentum transfer squared, which is of particular interest on several physics topics.
A search for C P violation with an entangled system of Ξ − Ξ ¯ + pairs is performed, using ( 10 , 087 ± 44 ) × 10 6 J / ψ events collected with the BESIII experiment. A nine-dimensional helicity amplitude is used to fit e + e − → J / ψ → Ξ − Ξ ¯ + and its subsequent decays. The Ξ − and Ξ ¯ + decay parameters are determined with higher precision compared to the best results reported so far. Furthermore, the strong phase difference, ( δ P − δ S ) = ( 0.3 ± 1.2 ± 0.2 ) × 10 − 2 rad , and the weak phase difference, ( ξ P − ξ S ) = ( − 0.2 ± 1.2 ± 0.1 ) × 10 − 2 rad , are directly determined. These are the most precise measurements to date. The C P asymmetry observables A C P Ξ = ( − 7.8 ± 4.8 ± 0.8 ) × 10 − 3 and Δ ϕ C P Ξ = ( 0.6 ± 5.1 ± 0.2 ) × 10 − 3 rad are determined, which are consistent with C P conservation. In addition, independent measurements of the Λ decay parameter and C P asymmetry A C P Λ = ( − 2.9 ± 4.3 ± 0.7 ) × 10 − 3 are also obtained, which are in agreement with the previous measurements, but with much improved precision.
We report a direct search for a new gauge boson, X , with a mass of 17 MeV / c 2 , which could explain the anomalous excess of e + e − pairs observed in the Be 8 nuclear transitions. The search is conducted in the charmonium decays χ c J → X J / ψ ( J = 0 , 1 , 2 ) via the radiative transition ψ ( 3686 ) → γ χ c J using ( 2712.4 ± 14.3 ) × 10 6 ψ ( 3686 ) events collected with the BESIII detector at the BEPCII collider. No significant signal is observed, and the updated upper limit on the coupling strength of charm quark and the new gauge boson, ε c , is set to be | ε c | < 1.2 × 10 − 2 at 90% confidence level. We also report new constraints on the mixing strength ε between the Standard Model photon and dark photon γ ′ in the mass range from 5 to 300 MeV / c 2 . The upper limits at 90% confidence level vary within ( 2.5 – 17.5 ) × 10 − 3 depending on the γ ′ mass.
About Me
Staff of the school of physics, Liaoning University,China.
Staff of the school of physics, Liaoning University,China.