Ching-Fu Wang

Dr. Ching-Fu Wang

Biomedical Engineering Research and Development Center
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
YKYi-Feng Ko
Yi-Feng Ko
PKPei-Hsin Kuo
Pei-Hsin Kuo
Ching-Fu WangChing-Fu Wang
Ching-Fu Wang
YCYu-Jen Chen
Yu-Jen Chen
PCPei-Chi Chuang
Pei-Chi Chuang
YCYou-Yin Chen
You-Yin Chen
Rapid eye movement (REM) sleep behavior disorder (RBD) is associated with Parkinson’s disease (PD). In this study, a smartwatch-based sensor is utilized as a convenient tool to detect the abnormal RBD phenomenon in PD patients. Instead, a questionnaire with sleep quality assessment and sleep physiological indices, such as sleep stage, activity level, and heart rate, were measured in the smartwatch sensors. Therefore, this device can record comprehensive sleep physiological data, offering several advantages such as ubiquity, long-term monitoring, and wearable convenience. In addition, it can provide the clinical doctor with sufficient information on the patient’s sleeping patterns with individualized treatment. In this study, a three-stage sleep staging method (i.e., comprising sleep/awake detection, sleep-stage detection, and REM-stage detection) based on an accelerometer and heart-rate data is implemented using machine learning (ML) techniques. The ML-based algorithms used here for sleep/awake detection, sleep-stage detection, and REM-stage detection were a Cole–Kripke algorithm, a stepwise clustering algorithm, and a k-means clustering algorithm with predefined criteria, respectively. The sleep staging method was validated in a clinical trial. The results showed a statistically significant difference in the percentage of abnormal REM between the control group (1.6 ± 1.3; n = 18) and the PD group (3.8 ± 5.0; n = 20) (p = 0.04). The percentage of deep sleep stage in our results presented a significant difference between the control group (38.1 ± 24.3; n = 18) and PD group (22.0 ± 15.0, n = 20) (p = 0.011) as well. Further, our results suggested that the smartwatch-based sensor was able to detect the difference of an abnormal REM percentage in the control group (1.6 ± 1.3; n = 18), PD patient with clonazepam (2.0 ± 1.7; n = 10), and without clonazepam (5.7 ± 7.1; n = 10) (p = 0.007). Our results confirmed the effectiveness of our sensor in investigating the sleep stage in PD patients. The sensor also successfully determined the effect of clonazepam on reducing abnormal REM in PD patients. In conclusion, our smartwatch sensor is a convenient and effective tool for sleep quantification analysis in PD patients.

25 February 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Ching-Fu WangChing-Fu Wang
Ching-Fu Wang
TWTing-Yun Wang
Ting-Yun Wang
PKPei-Hsin Kuo
Pei-Hsin Kuo
HWHan-Lin Wang
Han-Lin Wang
SLShih-Zhang Li
Shih-Zhang Li
YCYou-Yin Chen
You-Yin Chen
Wearable cuffless photoplethysmographic blood pressure monitors have garnered widespread attention in recent years; however, the long-term performance values of these devices are questionable. Most cuffless blood pressure monitors require initial baseline calibration and regular recalibrations with a cuffed blood pressure monitor to ensure accurate blood pressure estimation, and their estimation accuracy may vary over time if left uncalibrated. Therefore, this study assessed the accuracy and long-term performance of an upper-arm, cuffless photoplethysmographic blood pressure monitor according to the ISO 81060-2 standard. This device was based on a nonlinear machine-learning model architecture with a fine-tuning optimized method. The blood pressure measurement protocol followed a validation procedure according to the standard, with an additional four weekly blood pressure measurements over a 1-month period, to assess the long-term performance values of the upper-arm, cuffless photoplethysmographic blood pressure monitor. The results showed that the photoplethysmographic signals obtained from the upper arm had better qualities when compared with those measured from the wrist. When compared with the cuffed blood pressure monitor, the means ± standard deviations of the difference in BP at week 1 (baseline) were −1.36 ± 7.24 and −2.11 ± 5.71 mmHg for systolic and diastolic blood pressure, respectively, which met the first criterion of ≤5 ± ≤8.0 mmHg and met the second criterion of a systolic blood pressure ≤ 6.89 mmHg and a diastolic blood pressure ≤ 6.84 mmHg. The differences in the uncalibrated blood pressure values between the test and reference blood pressure monitors measured from week 2 to week 5 remained stable and met both criteria 1 and 2 of the ISO 81060-2 standard. The upper-arm, cuffless photoplethysmographic blood pressure monitor in this study generated high-quality photoplethysmographic signals with satisfactory accuracy at both initial calibration and 1-month follow-ups. This device could be a convenient and practical tool to continuously measure blood pressure over long periods of time.

27 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JCJia-Wei Chen
Jia-Wei Chen
HHHsin-Kai Huang
Hsin-Kai Huang
YFYu-Ting Fang
Yu-Ting Fang
YLYen-Ting Lin
Yen-Ting Lin
SLShih-Zhang Li
Shih-Zhang Li
YCYou-Yin Chen
You-Yin Chen
Ambulatory blood pressure (BP) monitoring (ABPM) is vital for screening cardiovascular activity. The American College of Cardiology/American Heart Association guideline for the prevention, detection, evaluation, and management of BP in adults recommends measuring BP outside the office setting using daytime ABPM. The recommendation to use night–day BP measurements to confirm hypertension is consistent with the recommendation of several other guidelines. In recent studies, ABPM was used to measure BP at regular intervals, and it reduces the effect of the environment on BP. Out-of-office measurements are highly recommended by almost all hypertension organizations. However, traditional ABPM devices based on the oscillometric technique usually interrupt sleep. For all-day ABPM purposes, a photoplethysmography (PPG)-based wrist-type device has been developed as a convenient tool. This optical, noninvasive device estimates BP using morphological characteristics from PPG waveforms. As measurement can be affected by multiple variables, calibration is necessary to ensure that the calculated BP values are accurate. However, few studies focused on adaptive calibration. A novel adaptive calibration model, which is data-driven and embedded in a wearable device, was proposed. The features from a 15 s PPG waveform and personal information were input for estimation of BP values and our data-driven calibration model. The model had a feedback calibration process using the exponential Gaussian process regression method to calibrate BP values and avoid inter- and intra-subject variability, ensuring accuracy in long-term ABPM. The estimation error of BP (ΔBP = actual BP—estimated BP) of systolic BP was −0.1776 ± 4.7361 mmHg; ≤15 mmHg, 99.225%, and of diastolic BP was −0.3846 ± 6.3688 mmHg; ≤15 mmHg, 98.191%. The success rate was improved, and the results corresponded to the Association for the Advancement of Medical Instrumentation standard and British Hypertension Society Grading criteria for medical regulation. Using machine learning with a feedback calibration model could be used to assess ABPM for clinical purposes.

9 May 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
CKChao-Hung Kuo
Chao-Hung Kuo
JCJia-Wei Chen
Jia-Wei Chen
YYYi Yang
Yi Yang
YLYu-Hao Lan
Yu-Hao Lan
SLShaowei Lu
Shaowei Lu
YCYou-Yin Chen
You-Yin Chen
An exoskeleton, a wearable device, was designed based on the user’s physical and cognitive interactions. The control of the exoskeleton uses biomedical signals reflecting the user intention as input, and its algorithm is calculated as an output to make the movement smooth. However, the process of transforming the input of biomedical signals, such as electromyography (EMG), into the output of adjusting the torque and angle of the exoskeleton is limited by a finite time lag and precision of trajectory prediction, which result in a mismatch between the subject and exoskeleton. Here, we propose an EMG-based single-joint exoskeleton system by merging a differentiable continuous system with a dynamic musculoskeletal model. The parameters of each muscle contraction were calculated and applied to the rigid exoskeleton system to predict the precise trajectory. The results revealed accurate torque and angle prediction for the knee exoskeleton and good performance of assistance during movement. Our method outperformed other models regarding the rate of convergence and execution time. In conclusion, a differentiable continuous system merged with a dynamic musculoskeletal model supported the effective and accurate performance of an exoskeleton controlled by EMG signals.

27 May 2024 in Healthcare
Verified
Journal Article
Open access
PDF file
YLYi-Jun Lin
Yi-Jun Lin
CCChia-Ying Chung
Chia-Ying Chung
CCCarl P.C. Chen
Carl P.C. Chen
YHYu-Wei Hsieh
Yu-Wei Hsieh
Ching-Fu WangChing-Fu Wang
Ching-Fu Wang
CCChih-Chi Chen
Chih-Chi Chen
Home exercise programs are beneficial in managing frozen shoulder (FS), yet adherence remains challenging. This pilot study introduces the remote app, Defrozen, designed for home exercises and assesses its feasibility and clinical outcomes in FS patients undergoing intra-articular and sub-acromial corticosteroid treatment. Over a four-week period, patients used the Defrozen-app, engaging in guided exercises. The feasibility of the intervention was assessed through several measurement scales, including adherence, the Technology Acceptance Model 2 (TAM2), the System Usability Scale (SUS), and User Satisfaction and Engagement (USE). Clinical outcomes included pain scale, Oxford Shoulder Score (OSS), Quick Disability of the Arm, Shoulder, and Hand (QuickDASH) Score, and passive range of motion. The TAM2 results indicated high perceived usefulness (4.5/5), ease of use (4.8/5), and intention to use (4.4/5); the SUS score was high at 81.7/100, complemented by USE scores reflecting ease of learning (4.9/5) and satisfaction (4.3/5). Clinical outcomes showed significant pain reduction, improved shoulder function, reduced shoulder-related disability, and increased shoulder range of motion. These findings suggest the Defrozen-app as a promising solution for FS, significantly improving adherence and showing potential to enhance clinical outcomes. However, these clinical outcome results are preliminary and necessitate further validation through a large-scale randomized controlled trial to definitively confirm efficacy and assess long-term benefits.

16 April 2025 in APL Bioengineering
Verified
Journal Article
Open access
YKYun-Ting Kuo
Yun-Ting Kuo
HWHan-Lin Wang
Han-Lin Wang
BCBo-Wei Chen
Bo-Wei Chen
Ching-Fu WangChing-Fu Wang
Ching-Fu Wang
YLYu-Chun Lo
Yu-Chun Lo
YCYou-Yin Chen
You-Yin Chen
Neural signal degradation poses a significant challenge in maintaining stable performance when decoding motor tasks using multiunit activity (MUA) and local field potential (LFP) signals in the implantable brain machine interface (iBMI) applications. Effective methods for imputing degraded or missing signals are essential to restore neural signal integrity, thereby improving decoding accuracy and system robustness over long-term recordings with fluctuating signal quality. This study introduces a confidence-weighted Bayesian linear regression (CW-BLR) approach to impute neural signals affected by degradation, enhancing the robustness and consistency of decoding. The performance of CW-BLR was compared to traditional methods—mean imputation (Mean-imp) and Gaussian-mixture-model-based expectation–maximization (GMM-EM)—using a kernel-sliced inverse regression (kSIR) decoder to evaluate decoding outcomes. Four Wistar rats were trained to perform a forelimb-reaching task while neural activity (MUA and LFPs) was recorded over 27 days. CW-BLR imputed signals degraded during days 8–27. Decoding performance was evaluated using kSIR and compared with Mean-imp and GMM-EM. CW-BLR demonstrated superior performance by effectively preserving both temporal and spatial dependencies within the neural signals. CW-BLR-imputed data significantly improved decoding accuracy over traditional imputation methods, with the kSIR decoder showing consistently higher performance, particularly in maintaining signal quality from the degraded period. CW-BLR offers a robust and effective imputation framework for iBMI applications, addressing signal degradation challenges and maintaining accurate decoding over prolonged recordings. By utilizing confidence-based quality metrics, CW-BLR surpasses traditional methods, providing stable neural decoding across fluctuating signal quality scenarios.