Stefano Quaia

Prof. Dr. Stefano Quaia


Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2011 in Electric Power Systems Research
Verified
Journal Article
Closed access
MDMaurizio Delfanti
Maurizio Delfanti
SQStefano Quaia
Stefano Quaia

14 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
DLDavide Lauria
Davide Lauria
Fabio MottolaFabio Mottola
Fabio Mottola
SQStefano Quaia
Stefano Quaia
The loadability characteristics of overhead transmission lines (OHLs) is certainly not a new topic. However, driven by sustainability issues, the increasing need to exploit existing electrical infrastructures as much as possible, has given OHL loadability a renowned central role and, recently, new investigations on this subject have been carried out. OHL loadability is generally investigated by means of numerical methods. Even though this approach allows deducing useful information in both planning and operation stage, it does not permit to capture all the insights obtainable by an analytical approach. The goal of this paper is to tailor a general analytical formulation for the loadability of OHLs. The first part of the paper is devoted to the base-case of uncompensated OHLs. Later, aiming to demonstrate the inherent feasibility and flexibility of the novel approach proposed, the less frequent case of shunt compensated radial OHLs is investigated as well. The analytical formulation is combined with the use of circular diagrams. Such diagrams allow a geometrical interpretation of the analytical relationships and are very useful to catch the physical insights of the problem. Finally, in order to show the applicability of the new analytical approach, a practical example is provided. The example concerns calculation of the loadability characteristics of typical 400 kV single-circuit OHLs.

29 September 2022 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
FGFEDERICO GATTA
FEDERICO GATTA
DLDavide Lauria
Davide Lauria
SQStefano Quaia
Stefano Quaia
SLStefano Lauria
Stefano Lauria

20 July 2022 in Electrical Engineering
Verified
Journal Article
Open access
PDF file
SQStefano Quaia
Stefano Quaia
AMAlessandro Mauri
Alessandro Mauri
MMMatteo Marega
Matteo Marega
AMAlessio Marchesin
Alessio Marchesin
DRDavide Rampazzo
Davide Rampazzo
CVChiara Vergine
Chiara Vergine
Different harmful events affecting high voltage overhead lines (OHLs) cause changes in the mechanical tension (tensile strength) of conductors. A mechanical monitoring of OHLs, therefore, can provide useful additional information (compared with the information provided by the widely used SCADA systems) about the power system state. The tension measurements combined with a few environmental measurements (air temperature, wind speed) can be used for an automatic (fast) detection of different events and for their approximate location along an OHL, reducing the impact of these events. Referring to 132–150 kV sub-transmission OHLs, this paper proposes some original algorithms, based on the mechanical monitoring of OHLs, for the automatic detection of the following events: conductor breaking, fall of trees on the conductors, ice/snow sleeve accretion on the conductors, strands breaking and galloping. The proposed algorithms require a limited number of sensors placed along the OHLs for measurements of the conductor tension and weather-related quantities.

1 January 1998
Verified
Conference Paper
Closed access
ABA. Boscolo
A. Boscolo
SQStefano Quaia
Stefano Quaia
FTF. Tosato
F. Tosato
Voltage sags can be compensated at low voltage level through using no-energy stored voltage conditioners based on power electronic components. Different compensation principles and power semiconductor devices (SCRs, GTOs, IGBTs) can be used, with different expected performances. This paper illustrates the advantages offered in voltage sag compensation by conditioners based on high switching frequency components and underlines the need for an in-depth voltage sag characterization.

13 November 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
SQStefano Quaia
Stefano Quaia
AMAlessio Marchesin
Alessio Marchesin
DRDavide Rampazzo
Davide Rampazzo
CMCristian Mancuso
Cristian Mancuso
Despite the good operating results of passive anti‐icing devices installed by the Italian transmission system operator (TSO) on high‐voltage overhead lines (OHLs), the increasing number and consequences of wet snow events have prompted consideration of other anti‐icing measures. In particular, attention focuses on the thermal approach, which is intended to achieve – before, or in the early stage of wet snow events – the anti‐icing current in OHL phase conductors where snow sleeve formation is foreseen. The authors carried out a specific anti‐icing study with reference to a 132 kV critical path in an area of the Apennines, with simulation results illustrated in this study. Anti‐icing measures investigated were (i) load shifting actions and (ii) insertion of shunt reactors used as ballast loads. The results show that shunt reactors are the most effective anti‐icing measure. The main disadvantage of this innovative solution is the degradation of voltage regulation in the area. However, this downside can be limited by combining the insertion of reactors with control of autotransformers under load tap changers. Similar results are obtained from analyses of other critical areas. As a result of these findings, the Italian TSO is now undertaking the installation of the first ballast reactors.