Arjan Singh Kahlon

Mr. Arjan Singh Kahlon

University of Pennsylvania, Philadelphia, Mississippi, USA
+2
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in Biomechanics
Verified
Journal Article
Open access
PDF file
Arjan Singh KahlonArjan Singh Kahlon
Arjan Singh Kahlon
Ashwini SansareAshwini Sansare
Ashwini Sansare
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Gait analysis has applications in medical diagnosis, biometrics, and development of therapeutic rehabilitation interventions (such as orthotics, prosthetics, and exoskeletons). While offering accurate measurements, gait laboratories are expensive, not scalable, and not easily accessible. In a pandemic-afflicted world, where telemedicine is crucial, there is need for subject-driven data remote collection. This study proposed a remote and purely subject-driven procedure for reproducible and scalable collection of real-life gait data. To evaluate the feasibility of our proposed procedure, the spatiotemporal parameters of gait were compared across two real-life terrains using a smartphone application on a focus population of healthy middle-aged individuals. Previous research validated smartphone motion sensors as accurate instruments for gait analysis, but required highly supervised, controlled environments on smaller sample sizes, thereby limiting application in real-life gait analysis. To this end, a custom-designed mobile application was developed to record lower extremity angular velocities on 69 healthy middle-aged adults; factoring in a subject-driven data submission error rate (DSER) of 17.4%, there were 57 usable data sets for analysis. Comparisons of spatiotemporal gait parameters across primary outcome measures on grass versus asphalt revealed significant measurable increases in gait duration (stride time), valley depth (max swing phase), and peak-to-valley (max stance phase to max swing phase). These results demonstrated the feasibility of using smartphones for a remote and fully subject-driven gait data collection. Additionally, our data analysis showed that even in short trials, a physical environmental load has a substantial and measurable effect on the gait of the understudied middle-aged population.

16 February 2026 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
JFJason Fink
Jason Fink
DNDogerno J. Norceide
Dogerno J. Norceide
Arjan Singh KahlonArjan Singh Kahlon
Arjan Singh Kahlon
KNKenneth T. Nguyen
Kenneth T. Nguyen
KWKevin Wu
Kevin Wu
RPRobert L. Parisien
Robert L. Parisien
Tranexamic acid (TXA) is increasingly used in total shoulder arthroplasty to minimize perioperative blood loss; however, the quality and objectivity of evidence supporting its use remain uncertain. Systematic reviews and meta-analyses are critical for informing clinical practice, but their conclusions can be affected by reporting bias—particularly spin, which may distort study findings and mislead clinical decision-making. Despite the rising interest in TXA for total shoulder arthroplasty, the extent to which spin is present in this body of literature has not been evaluated. Therefore, the purpose of this study was to analyze reporting bias in the form of spin present in systematic reviews and meta-analyses related to TXA use in shoulder arthroplasty. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, systematic reviews were collected from PubMed, Scopus, and Embase using the search “Shoulder Arthroplasty” AND “Tranexamic Acid” OR “TXA” AND “systematic review” OR “meta-analysis” in March of 2025. A MeaSurement Tool to Assess systematic Reviews (AMSTAR 2) was used to evaluate the quality of the studies. Associations between these factors and spin presence or type were determined using statistical tests, including t-tests, one-way analysis of variance, Fisher tests, and Spearman's rank coefficients. The initial database search identified 72 studies, of which 31 duplicates were removed. Twenty-one additional studies were removed after title and abstract screening, and 5 more were removed during full-text screening because they did not meet the inclusion criteria. Spin was present in 12 out of the 15 remaining study abstracts (80.0%), all of which were determined to contain misleading reporting, and 10 (66.7%) of which were also found to contain misleading interpretation. Furthermore, 12 of the 15 reviews (80.0%) received a critically low AMSTAR 2 confidence rating. The majority of systematic reviews on TXA use in shoulder arthroplasty received critically low AMSTAR 2 ratings, reflecting the poor quality of evidence in this area. This analysis highlights the widespread occurrence of spin and low-quality evidence in TXA use in shoulder arthroplasty reviews, underscoring the importance of critical evaluation and improved research quality.

7 March 2022
Verified
Conference Paper
Closed access
Arjan Singh KahlonArjan Singh Kahlon
Arjan Singh Kahlon
SKSara Khaksari
Sara Khaksari
ABAhad Behboodi
Ahad Behboodi
ASAshwini Sansare
Ashwini Sansare
Wearable systems can evaluate a subject’s gait without the need to meet a therapist. Some of these wearables are in the form of smartphone built-in sensors. Gait characteristics give us a knowledge of health status in individuals with movement disorders. In this study, we designed a gyroscope-based smartphone application for quantifying gait parameters through a built-in smartphone sensor. This method uses a custom created algorithm for measuring a person’s manner of walking. The outcome is an inexpensive application for tracking the prognosis of the disease and monitoring patient recovery that allows a point-of-care at-home monitoring of patients with limb problems.