Ahad Behboodi

Dr. Ahad Behboodi

Biomechanics, University of Nebraska at Omaha, Omaha, Nebraska, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
NZNicole Zahradka
Nicole Zahradka
Khushboo VermaKhushboo Verma
Khushboo Verma
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Barry BodtBarry Bodt
Barry Bodt
HWHenry Wright
Henry Wright
SLSamuel Lee
Samuel Lee
Video- and sensor-based gait analysis systems are rapidly emerging for use in ‘real world’ scenarios outside of typical instrumented motion analysis laboratories. Unlike laboratory systems, such systems do not use kinetic data from force plates, rather, gait events such as initial contact (IC) and terminal contact (TC) are estimated from video and sensor signals. There are, however, detection errors inherent in kinematic gait event detection methods (GEDM) and comparative study between classic laboratory and video/sensor-based systems is warranted. For this study, three kinematic methods: coordinate based treadmill algorithm (CBTA), shank angular velocity (SK), and foot velocity algorithm (FVA) were compared to ‘gold standard’ force plate methods (GS) for determining IC and TC in adults (n = 6), typically developing children (n = 5) and children with cerebral palsy (n = 6). The root mean square error (RMSE) values for CBTA, SK, and FVA were 27.22, 47.33, and 78.41 ms, respectively. On average, GED was detected earlier in CBTA and SK (CBTA: −9.54 ± 0.66 ms, SK: −33.41 ± 0.86 ms) and delayed in FVA (21.00 ± 1.96 ms). The statistical model demonstrated insensitivity to variations in group, side, and individuals. Out of three kinematic GEDMs, SK GEDM can best be used for sensor-based gait event detection.

1 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Ahad BehboodiAhad Behboodi
Ahad Behboodi
NZNicole Zahradka
Nicole Zahradka
HWHenry Wright
Henry Wright
JAJames Alesi
James Alesi
SLSamuel Lee
Samuel Lee
A recently designed gait phase detection (GPD) system, with the ability to detect all seven phases of gait in healthy adults, was modified for GPD in children with cerebral palsy (CP). A shank-attached gyroscope sent angular velocity to a rule-based algorithm in LabVIEW to identify the distinct characteristics of the signal. Seven typically developing children (TD) and five children with CP were asked to walk on treadmill at their self-selected speed while using this system. Using only shank angular velocity, all seven phases of gait (Loading Response, Mid-Stance, Terminal Stance, Pre-Swing, Initial Swing, Mid-Swing and Terminal Swing) were reliably detected in real time. System performance was validated against two established GPD methods: (1) force-sensing resistors (GPD-FSR) (for typically developing children) and (2) motion capture (GPD-MoCap) (for both typically developing children and children with CP). The system detected over 99% of the phases identified by GPD-FSR and GPD-MoCap. Absolute values of average gait phase onset detection deviations relative to GPD-MoCap were less than 100 ms for both TD children and children with CP. The newly designed system, with minimized sensor setup and low processing burden, is cosmetic and economical, making it a viable solution for real-time stand-alone and portable applications such as triggering functional electrical stimulation (FES) in rehabilitation systems. This paper verifies the applicability of the GPD system to identify specific gait events for triggering FES to enhance gait in children with CP.

18 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Vahid MohammadiVahid Mohammadi
Vahid Mohammadi
RSRamin Shahbad
Ramin Shahbad
MHMojtaba Hosseini
Mojtaba Hosseini
HGHossein Gholampour
Hossein Gholampour
SAEED SHIRY GHIDARYSAEED SHIRY GHIDARY
SAEED SHIRY GHIDARY
Ahad BehboodiAhad Behboodi
Ahad Behboodi
Haptic hands and grippers, designed to enable skillful object manipulation, are pivotal for high-precision interaction with environments. These technologies are particularly vital in fields such as minimally invasive surgery, where they enhance surgical accuracy and tactile feedback: in the development of advanced prosthetic limbs, offering users improved functionality and a more natural sense of touch, and within industrial automation and manufacturing, they contribute to more efficient, safe, and flexible production processes. This paper presents the development of a two-finger robotic hand that employs simple yet precise strategies to manipulate objects without damaging or dropping them. Our innovative approach fused force-sensitive resistor (FSR) sensors with the average current of servomotors to enhance both the speed and accuracy of grasping. Therefore, we aim to create a grasping mechanism that is more dexterous than grippers and less complex than robotic hands. To achieve this goal, we designed a two-finger robotic hand with two degrees of freedom on each finger; an FSR was integrated into each fingertip to enable object categorization and the detection of the initial contact. Subsequently, servomotor currents were monitored continuously to implement impedance control and maintain the grasp of objects in a wide range of stiffness. The proposed hand categorized objects’ stiffness upon initial contact and exerted accurate force by fusing FSR and the motor currents. An experimental test was conducted using a Yale–CMU–Berkeley (YCB) object set consisted of a foam ball, an empty soda can, an apple, a glass cup, a plastic cup, and a small milk packet. The robotic hand successfully picked up these objects from a table and sat them down without inflicting any damage or dropping them midway. Our results represent a significant step forward in developing haptic robotic hands with advanced object perception and manipulation capabilities.

28 September 2022 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Ahad BehboodiAhad Behboodi
Ahad Behboodi
WLWalker A. Lee
Walker A. Lee
VHVictoria S. Hinchberger
Victoria S. Hinchberger
DDDiane L. Damiano
Diane L. Damiano
Background: Brain–computer interfaces (BCI), initially designed to bypass the peripheral motor system to externally control movement using brain signals, are additionally being utilized for motor rehabilitation in stroke and other neurological disorders. Also called neurofeedback training, multiple approaches have been developed to link motor-related cortical signals to assistive robotic or electrical stimulation devices during active motor training with variable, but mostly positive, functional outcomes reported. Our specific research question for this scoping review was: for persons with non-progressive neurological injuries who have the potential to improve voluntary motor control, which mobile BCI-based neurofeedback methods demonstrate or are associated with improved motor outcomes for Neurorehabilitation applications? Methods: We searched PubMed, Web of Science, and Scopus databases with all steps from study selection to data extraction performed independently by at least 2 individuals. Search terms included: brain machine or computer interfaces, neurofeedback and motor; however, only studies requiring a motor attempt, versus motor imagery, were retained. Data extraction included participant characteristics, study design details and motor outcomes. Results: From 5109 papers, 139 full texts were reviewed with 23 unique studies identified. All utilized EEG and, except for one, were on the stroke population. The most commonly reported functional outcomes were the Fugl-Meyer Assessment (FMA; n = 13) and the Action Research Arm Test (ARAT; n = 6) which were then utilized to assess effectiveness, evaluate design features, and correlate with training doses. Statistically and functionally significant pre-to post training changes were seen in FMA, but not ARAT. Results did not differ between robotic and electrical stimulation feedback paradigms. Notably, FMA outcomes were positively correlated with training dose. Conclusion: This review on BCI-based neurofeedback training confirms previous findings of effectiveness in improving motor outcomes with some evidence of enhanced neuroplasticity in adults with stroke. Associative learning paradigms have emerged more recently which may be particularly feasible and effective methods for Neurorehabilitation. More clinical trials in pediatric and adult neurorehabilitation to refine methods and doses and to compare to other evidence-based training strategies are warranted.

30 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
NZNicole Zahradka
Nicole Zahradka
Ahad BehboodiAhad Behboodi
Ahad Behboodi
HWHenry Wright
Henry Wright
Barry BodtBarry Bodt
Barry Bodt
SLSamuel Lee
Samuel Lee
Functional electrical stimulation systems are used as neuroprosthetic devices in rehabilitative interventions such as gait training. Stimulator triggers, implemented to control stimulation delivery, range from open- to closed-loop controllers. Finite-state controllers trigger stimulators when specific conditions are met and utilize preset sequences of stimulation. Wearable sensors provide the necessary input to differentiate gait phases during walking and trigger stimulation. However, gait phase detection is associated with inherent system delays. In this study, five stimulator triggers designed to compensate for gait phase detection delays were tested to determine which trigger most accurately delivered stimulation at the desired times of the gait cycle. Motion capture data were collected on seven typically-developing children while walking on an instrumented treadmill. Participants wore one inertial measurement unit on each ankle and gyroscope data were streamed into the gait phase detection algorithm. Five triggers, based on gait phase detection, were used to simulate stimulation to five muscle groups, bilaterally. For each condition, stimulation signals were collected in the motion capture software via analog channels and compared to the desired timing determined by kinematic and kinetic data. Results illustrate that gait phase detection is a viable finite-state control, and appropriate system delay compensations, on average, reduce stimulation delivery delays by 6.7% of the gait cycle.

1 June 2019
Verified
Conference Paper
Closed access
Ahad BehboodiAhad Behboodi
Ahad Behboodi
SLS.C.K. Lee
S.C.K. Lee
Recent commercial availability of a stacked dielectric elastomer actuator (SDEA) has opened up possibilities of their use as “artificial muscles” for rehabilitation robots and powered exoskeleton devices. Made by CTsystems, this actuator (CT_SDEA) is made from soft materials, and offers a lightweight and acoustically noiseless alternative to DC motor actuators used in conventional rehabilitation robotic systems. The purpose of the present work was to benchmark the electromechanical properties of CT-SDEAs to assess its capabilities and limitations for mechanizing rehabilitation robots. The CT-SDEAs tested in this study showed 21 ms electrometrical delay, and their calculated strain-rate was 660 %/s. They could generate 21.74 N of force and have a 426 W/kg power-to-mass ratio. Their longitudinal strain was measured at 3.3%. Additionally, their steady state current consumption was measured 39 $\mu$ A. CT-SDEAs' fast response, short electromechanical delay and high strain-rate, make them highly suitable for closed-loop control. Additionally, their force generation capability, fast response, high power-to-mass ratio, and low steady state power consumption make them a strong candidates for exoskeleton applications. It's longitudinal strain (3.3%) however, was less than that of skeletal muscle (20%). Depending on the application, their use may require the addition of mechanical linkages, for force to displacement conversion.