An experimental program was conducted to ascertain the efficiency of Carbon Fiber Reinforced Polymer (CFRP) in enhancing the flexural response of hollow section reinforced concrete (RC) beams. Nine beams were tested under four-point bending in three groups. Beams were categorized to reflect the presence or configuration of the CFRP sheet. Each group consisted of three beams: one with a solid section, one with a square mm × mm opening and 1 with mm × mm opening. Beams in 1st group were tested in as-built conditions. Beams in the 2nd group were strengthened with a single CFRP sheet bonded to their bottom sides. Configuration of CFRP sheet was altered to U-shape applied to the tension side of 3rd group beams. The inclusion of openings, regardless of their size, did not result in degradation of ultimate load and corresponding deflections. However, cracking loads were found to decline as the opening size increased. Regardless of the opening size and CFRP configuration, ultimate loads of beams increased with the application of CFRP. However, this improvement was limited to the debonding and rupture of CFRP in group 2 and 3 beams, respectively. A comparison in the behavior of group 2 and 3 beams revealed that the application of the U-shape CFRP sheet yielded better flexural performance in comparison with the flat-CFRP sheet bonded to the bottom of beams. In the end, In order to further evaluate the economic and performance benefits of these beams, the cost-benefit analysis was also performed. The analysis showed that the feasibility of the hollow section RC beams is more than the solid section RC beams.
Full-scale testing of multiple span girders is scarce in the literature, often related to the complexity of loading setup and time constraints. The importance of full-scale tests is manifested in the fact that useful information regarding failure mechanisms can be obtained. In addition, important guidelines can be established for structural designers. Further, results from full-scale tests can help establish constitutive laws for various mechanisms involved in the response of actual structures. The structural performance of individual members can be assessed by monitoring their strains at service and ultimate loads. This study presents a comparison of experimentally monitored strains on longitudinal steel bars, stirrups, and prestressing tendons embedded in single and multi-span full-scale precast pre-tensioned girders. These girders were constructed and detailed to simulate the response of newly proposed straddle-type monorail girders. Single-span girders were tested under monotonic two-point service and ultimate loads, whereas multi-span girders were tested under both two- and four-point service and ultimate load. It was revealed that longitudinal steel and prestressing tendon strains monitored within single-span girders at service and ultimate loads were significantly higher than those recorded at corresponding locations in multi-span girders.