Yunhua Luo

Prof. Yunhua Luo

University of Manitoba, Winnipeg, Manitoba, Canada
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2021 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Closed access
Yunhua LuoYunhua Luo
Yunhua Luo
Voigt and Reuss models do not make any assumption regarding composite microstructure, but they are only able to estimate bounds rather than values of composite properties. To enable the models to predict elastic properties of particulate composites, we isotropized Voigt and Reuss models based on the equivalence of normal and shear strain energy respectively in a representative volume element, and derived a set of simple and uncoupled equations for the prediction of composite Young’s modulus and shear modulus. Composite bulk modulus and Poisson’s ratio can then be determined either by the elasticity relationships or by generalization of the isotropized Voigt-Reuss equations. Validation with reported experimental data show that, for composites with phase properties of either small or large contrast, isotropized Voigt-Reuss model has similar accuracy as the widely used micromechanical models, for the prediction of Young’s modulus and shear modulus.

17 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
Yunhua LuoYunhua Luo
Yunhua Luo
The Poisson effect, measured by the Poisson’s ratio, plays an important role in the regulation of the elastic properties of composite materials, but it is not considered in the conventional Voigt (iso-strain) and Reuss (iso-stress) formulas, which explains why the formulas are inaccurate even if the iso-strain or the iso-stress conditions are satisfied. To consider the Poisson effect, we derived a set of new formulas based on the governing equations of elasticity. The obtained formulas show greater mathematical complexity. To further understand how the Poisson effect influences composite elastic properties, two types of finite element models (FEM) were constructed to simulate the situations where the Poisson effect does or does not have an influence. The results show that the conventional Voigt and Reuss formulas are special cases of the newly derived ones. The Poisson effect induces secondary strains and stresses into the phase materials, which demands more strain energy to achieve the same deformation in the primary (loading) direction, and thus increases composite stiffness; the magnitude of the increase is dependent on the contrast of phase properties. The findings may have significant impact on the study of the emerging nanocomposites and functionally graded materials, where the conventional Voigt and Reuss formulas have wide applications.

1 August 1998 in Computer Methods in Applied Mechanics and Engineering
Verified
Journal Article
Closed access
Yunhua LuoYunhua Luo
Yunhua Luo

21 April 2013 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
Yunhua LuoYunhua Luo
Yunhua Luo
ZFZannatul Ferdous
Zannatul Ferdous
WLWilliam D. Leslie
William D. Leslie

17 October 2011 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
PDF file
Yunhua LuoYunhua Luo
Yunhua Luo
ZFZ Ferdous
Z Ferdous
WLW D Leslie
W D Leslie
To more accurately assess osteoporotic hip fracture risk in a specific patient, a dual-energy X-ray absorptiometry (DXA)-based finite element model was constructed from the patient’s femur DXA image. The outermost contour of the femur bone segmented from the DXA image was used to generate a finite element mesh. Bone mechanical properties, such as Young’s modulus, are correlated with areal bone mineral density (BMD) captured in the DXA image. A quasi-static loading condition representing a sideway fall was applied to the finite element model. Three fracture risk indices were introduced and expressed as ratios of internal forces caused by impact forces occurring in sideway fall to bone ultimate cross-section strength at the three critical locations, i.e. the femoral neck, the intertrochanteric region, and the subtrochanteric region. The proposed finite element modelling procedure was validated against six representative clinical cases extracted from the Manitoba BMD database, where initial and follow-up DXA images have been taken to monitor longitudinal variation of areal BMD in individual patients. It was found from the clinical validation that variations in the proposed fracture risk indices have the same trends as those indicated by the conventional areal BMD and T-score. In addition, by the three proposed fracture risk indices it is possible to further identify the specific fracture location. It was also found that for the same subject, the variations in the three fracture risk indices have quite different magnitudes, with intertrochanteric region the largest and subtrochanteric region the smallest, which is probably owing to the different content of trabecular and cortical bones in the three regions. With further development, it is promising that the proposed DXA-based finite element model will be a useful tool for accurate assessment of osteoporosis development and for treatment monitoring.

12 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Yunhua LuoYunhua Luo
Yunhua Luo
Personalized orthopedic devices are increasingly favored for their potential to enhance long-term treatment success. Despite significant advancements across various disciplines, the seamless integration and full automation of personalized orthopedic treatments remain elusive. This paper identifies key interdisciplinary gaps in integrating and automating advanced technologies for personalized orthopedic treatment. It begins by outlining the standard clinical practices in orthopedic treatments and the extent of personalization achievable. The paper then explores recent innovations in artificial intelligence, biomaterials, genomic and proteomic analyses, lab-on-a-chip, medical imaging, image-based biomechanical finite element modeling, biomimicry, 3D printing and bioprinting, and implantable sensors, emphasizing their contributions to personalized treatments. Tentative strategies or solutions are proposed to address the interdisciplinary gaps by utilizing innovative technologies. The key findings highlight the need for the non-invasive quantitative assessment of bone quality, patient-specific biocompatibility, and device designs that address individual biological and mechanical conditions. This comprehensive review underscores the transformative potential of these technologies and the importance of multidisciplinary collaboration to integrate and automate them into a cohesive, intelligent system for personalized orthopedic treatments.