Mei-Feng Lai

Prof. Dr. Mei-Feng Lai


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Ching-Wen LouChing-Wen Lou
Ching-Wen Lou
MLMeng-Chen Lin
Meng-Chen Lin
CHChen-Hung Huang
Chen-Hung Huang
MLMei-Feng Lai
Mei-Feng Lai
BSBing-Chiuan Shiu
Bing-Chiuan Shiu
Jia-Horng LinJia-Horng Lin
Jia-Horng Lin
Electrospinning is an efficient method of producing nanofibers out of polymers that shows a great potential for the filtration territory. Featuring water-soluble chitosan (WS-CS), a low-pollution process and a self-made needleless machine, PVA/WS-CS nanofibrous membranes were prepared and evaluated for nanofiber diameter, bacteriostatic property, filtration efficiency, pressure drop, and quality factor. Test results indicate that the minimal fiber diameter was 216.58 ± 58.15 nm. Regardless of the WS-CS concentration, all of the PVA/WS-CS nanofibrous membranes attained a high porosity and a high water vapor transmission rate (WVTR), with a pore size of 12.06–22.48 nm. Moreover, the membranes also exhibit bacteriostatic efficacy against Staphylococcus aureus, an optimal quality factor of 0.0825 Pa−1, and a filtration efficiency as high as 97.0%, that is 72.5% higher than that of common masks.

16 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Jia-Horng LinJia-Horng Lin
Jia-Horng Lin
PHPo-Wen Hsu
Po-Wen Hsu
CHChen-Hung Huang
Chen-Hung Huang
MLMei-Feng Lai
Mei-Feng Lai
BSBing-Chiuan Shiu
Bing-Chiuan Shiu
Ching-Wen LouChing-Wen Lou
Ching-Wen Lou
In this study, a low-melting-point polyester nonwoven fabric (L), a nylon spacer fabric (N), and a carbon fiber woven fabric (C) are laminated in different orders and then needle-bonded at a depth of 15.0 cm to form NLC, NLN, CLC, and CLN composites with a sandwich construction. Regardless of the lamination order, four composite types exhibit high tensile strengths and tearing strengths. Based on the ASTM D4935-18 test standard, the electromagnetic wave shielding measurement is conducted in a frequency range of 1~3 GHz. The two groups—NLC and CLN—demonstrate different electromagnetic wave shields, which are −45~−65 dB for the former, and −60 dB for the latter. According to FTTS-FA-003, in the specified requirements of the test method for electromagnetic shielding textiles, the proposed composites achieve level III, which is the highest standard, and are thus qualified for use in the aviation, construction, and commerce fields.

25 February 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Jia-Horng LinJia-Horng Lin
Jia-Horng Lin
PHPo-Yang Hsu
Po-Yang Hsu
CHChen-Hung Huang
Chen-Hung Huang
MLMei-Feng Lai
Mei-Feng Lai
BSBing-Chiuan Shiu
Bing-Chiuan Shiu
Ching-Wen LouChing-Wen Lou
Ching-Wen Lou
Noise pollution is the primary environmental issue that is increasingly deteriorated with the progress of modern industry and transportation; hence, the purpose of this study is to create flexible PU foam with mechanical properties and sound absorption. In this study, hollow ceramic microsphere (HCM) is used as the filler of polyurethane (PU) foam for mechanical reinforcement. The sound absorption efficacy of PU pores and the hollow attribute of HCM contribute to a synergistic sound absorption effect. HCM-filled PU foam is evaluated in terms of surface characteristic, mechanical properties, and sound absorption as related to the HCM content, determining the optimal functional flexible PU foam. The test results indicate that the presence of HCM strengthens the stability of the cell structure significantly. In addition, the synergistic effect can be proven by a 2.24 times greater mechanical strength and better sound absorption. Specifically, with more HCM, the flexible PU foam exhibits significantly improved sound absorption in high frequencies, suggesting that this study successfully generates functional PU foam with high mechanical properties and high sound absorption.

16 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Ching-Wen LouChing-Wen Lou
Ching-Wen Lou
JLJian-Hong Lin
Jian-Hong Lin
MLMei-Feng Lai
Mei-Feng Lai
CHChen-Hung Huang
Chen-Hung Huang
BSBing-Chiuan Shiu
Bing-Chiuan Shiu
Jia-Horng LinJia-Horng Lin
Jia-Horng Lin
Medical protective clothing is the first line of defense for medical staff, which makes the acquisition of protection and multiple function challenging. When it comes to contagious diseases, the physical properties of protective clothing are deemed the top priority and, subsequently, they have significant meaning for the structural design, production cost evaluation, convenient production, and innovation. In this study, nonwoven technology is employed to produce matrices in which mechanical properties are supported by Tencel fibers and recycled Kevlar fibers. Next, the electrostatic spinning is conducted to generate breathable and waterproof films. The nonwoven fabrics and membranes are combined to have diverse functions, forming lay-up compound matrices for medical protective clothing. Moreover, measurements are conducted to characterize the lay-up compound matrices in terms of the tensile strength, tearing strength, bursting strength, puncture resistance, stiffness, air-permeable property, surface resistance, comfort performance, sub-micron particulate filtration efficiency, and the penetration of synthetic blood. As for the nonwoven fabrics, the mechanical properties are significantly improved after Kevlar fibers are incorporated. The tensile strength is (62.6 ± 2.4) N along the machine direction (MD) and (50.1 ± 3.1) N along the cross machine direction (CD); the tearing strength is (29.5 ± 1.6) N along the MD and (43.0 ± 1.7) N along the CD; the bursting strength is (365.8 ± 5.0) kPa; and the puncture resistance is (22.6 ± 1.0) N. Moreover, the lay-up compound matrices exhibit a stiffness of (14.7 ± 0.2) cm along the MD and (14.6 ± 0.1) cm along the CD, a surface resistance of (2.85 × 109 ± 0.37 × 109) Ω, an air-permeable property of (45.4 ± 2.3) cm3/s/cm2, and sub-micron particulate filtration efficiency of over 98%. In the measurement for penetration of synthetic blood, the K40/PAN/TPU group prevents the synthetic blood from penetration. Hence, the incorporation of recycled Kevlar fibers and lay-up compound technique creates good physical properties, an appropriate comfort attribute, and functions, which suggests that this study provides a greater diversity and new concepts for the production of medical protective clothing.

27 September 2021 in Polymers
Verified
Journal Article
Open access
PDF file
Jia-Horng LinJia-Horng Lin
Jia-Horng Lin
YSYing-Huei Shih
Ying-Huei Shih
CHChen-Hung Huang
Chen-Hung Huang
MLMei-Feng Lai
Mei-Feng Lai
SLShu-An Lee
Shu-An Lee
Ching-Wen LouChing-Wen Lou
Ching-Wen Lou
In recent years, air filtration has been gaining much attention, and now people are much more concerned about antibacterial filters due to the spreading of COVID-19. The electret polypropylene (PP) nonwoven fabrics possess excellent filtration efficiency but a limited antibacterial effect against S. aureus and E. coli, and therefore triclosan is used in this study. Serving as an antibacterial agent, triclosan with a low molecular weight is an effective additive for the test results, indicating that the presence of triclosan strengthens the antibacterial effects of the filters. In addition, triclosan also strengthens the PP’s crystallinity, which in turn betters the filtration efficiency of the filters concurrently. Demonstrating powerful filtration and antibacterial performances, the antibacterial electret PP filters are highly qualified for filter applications.

26 April 2022 in Polymers
Verified
Journal Article
Open access
PDF file
YSYu-Tung Shih
Yu-Tung Shih
ACAn-Pang Chen
An-Pang Chen
MLMei-Feng Lai
Mei-Feng Lai
MLMei-Chen Lin
Mei-Chen Lin
BSBing-Chiuan Shiu
Bing-Chiuan Shiu
Jia-Horng LinJia-Horng Lin
Jia-Horng Lin
To reduce the bleeding time and to shorten the surgery time are vital to patients’ prog-nosis, therefore, in this study, high moisture absorption nonwoven composites are proposed to attain hemostasis in time. Polyacrylate fiber and Tencel® fibers at different blending ratios (10:90, 20:80, 30:70, 40:60, and 50:50) are used to form PT composite nonwoven. Next, composed of a 50:50 ratio, PT composite nonwoven exhibits the maximal vertical wicking height of 4.4 cm along the cross direction. Additionally, the UV-Vis absorption spectra analysis shows that at absorption waves of 413–415 nm, the occurring of distinct peaks suggests the presence of nanoparticles. The XRD patterns indicate the presence of silver nanoparticles with corresponding crystal planes of characteristic peaks at (111), (200), and (220). Polyacrylate/Tencel® nonwoven composites exhibit comparable adsorption capacity of blood and water molecules. In particular, 30PT composite nonwoven outperforms the control group, exhibiting 3.8 times and 4.7 times greater the water absorption and blood absorption, respectively. Moreover, a great number of red blood cells with a size of 4–6 μm agglomerate among fibers as observed in SEM images, while 6hr-PT composite dressing demonstrates the optimal antibacterial efficacy against Escherichia coli and Staphylococcus aureus, proven by the zone of inhibition being 1.9 mm and 0.8 mm separately. When in contact with plasma, hemostasis composites have plasma hemostasis prothrombin time of 97.9%, and activated partial thromboplastin time of 96.7%. As for animal hemostasis model, the arteria over the rats’ thigh bones is cut open perpendicularly, generating mass arteria hemorrhage. To attain hemostasis, it takes 46.5% shorter time when using composite dressings (experimental group) than the control group.