Lutz Gärtner

Dr. Lutz Gärtner

Hannover Medical School
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
LGLutz Gärtner
Lutz Gärtner
TLThomas Lenarz
Thomas Lenarz
ABAndreas Büchner
Andreas Büchner
In cochlear implants (CI) measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the electrode-nerve interface as well as establishing a basis for a map to program the speech processor. In a standard clinical setup recordings are averaged over 25–100 repetitions to allow for the detection of ECAPs within the noise floor. To obtain an amplitude growth function, these measurements are normally performed for 5–10 different stimulation levels. We evaluate a recording paradigm where the stimulation intensity is increased in quasi-continuous steps and instead of averaging repeated recordings with identical stimulation parameters, running averages over small intervals of stimulation levels are computed. The first visible nerve response was manually identified by two experts. Both recording paradigms were evaluated in 39 cochlear implants, showing an on average lower threshold of the first nerve response for the quasi-continuous measurement paradigm (Wilcoxon signed-rank test, p = 6.2e−08) compared to the clinical standard paradigm. The mean maximal loudness over all implants and stimulation electrodes was 13% lower at the 80 pulses/s quasi-continuous paradigm compared to the 44 pulses/s clinical standard paradigm. Beside a more robust determination of the ECAP threshold, the proposed quasi-continuous stimulation paradigm results in a more robust behavioral feedback of the CI user upon the maximal acceptable loudness percept. Furthermore this paradigm can also reveal the fine-structure in the amplitude growth function.

4 December 2009 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
LGLutz Gärtner
Lutz Gärtner
TLThomas Lenarz
Thomas Lenarz
GJGert Joseph
Gert Joseph
ABAndreas Büchner
Andreas Büchner
The CustomSoundEP software can record ECAP traces in an automated manner and calculate the ECAP threshold from them. These values are in good agreement with those determined by audiologists. Manual optimization measurements, as needed when using the predecessor version 3 of the software, are done by the software itself in the newer system. The programming of a cochlear implant speech processor is usually carried out in a subjective manner, influenced by the audiologist and the subject, and it takes considerable time. With increasing numbers of patients there is a growing need for a rapid and reliable technique to measure and analyse neural responses - one which could give suggestions for programming the speech processor and thus shorten the fitting procedure. In 30 patients, ECAP responses were recorded postoperatively in an automated procedure. ECAP thresholds were determined automatically by the AutoNRT(TM) (Automatic Neural Response Telemetry) software and visually by seven persons. The time required to determine a TECAP threshold for a single electrode contact was found to be between 0.5 and 1 min.

15 August 2020 in The Laryngoscope
Verified
Journal Article
Open access
PDF file
LGLutz Gärtner
Lutz Gärtner
ABAndreas Buechner
Andreas Buechner
AIAngelika Illg
Angelika Illg
TLThomas Lenarz
Thomas Lenarz
When the impedance of an electrode contact is highly increased in a cochlear implant, a failure of the appropriate electrode seems obvious. We present a case where impedances of some electrodes were at the lower edge of the normal range and not regarded as suspicious neither by the clinical fitting software nor by in‐vivo tests conducted by the implant manufacturer. However, speech comprehension was substantially degraded and sound perception distorted. Also, on the affected electrodes, loudness perception was compromised and responses of the electrically evoked compound action potential were no longer measureable. After re‐implantation, the subjective sound percept was clear again and speech comprehension scored much better than before. Later, inspection of the explant revealed shorts on the device and the implant was classified as device failure. Our case shows the importance of collecting longitudinal data of cochlear implant patients, i.e. device related technical measurements and hearing performance data, and the consideration of all these data in cases of patient complaints or suspected implant failures. Laryngoscope, 2020

22 January 2022 in Cochlear Implants International
Verified
Journal Article
Closed access
LGLutz Gärtner
Lutz Gärtner
TLThomas Lenarz
Thomas Lenarz
JIJurgita Ivanauskaite
Jurgita Ivanauskaite
ABAndreas Buechner
Andreas Buechner
To describe the influence of stimulus parameters on aberrant facial nerve stimulation in cochlear implant users.Retrospective case series (three ears – two patients). Cochlear implant patients with...

11 February 2022 in Life
Verified
Journal Article
Open access
PDF file
LGLutz Gärtner
Lutz Gärtner
TBTimo Bräcker
Timo Bräcker
MKMathias Kals
Mathias Kals
RPRichard T Penninger
Richard T Penninger
MBMareike Billinger-Finke
Mareike Billinger-Finke
ABAndreas Buechner
Andreas Buechner
This study assessed the safety and performance of ARTFit, a new tool embedded in MAESTRO, the cochlear implant (CI) system software by MED-EL GmbH (Innsbruck, Austria). ARTFit automatically measures thresholds of the electrically evoked compound action potential (ECAP) to produce initial ‘maps’ (ECAPMAPs), i.e., configuration settings of the audio processor that the audiologist switches to live mode and adjusts for comfortable loudness (LiveECAPMAPs). Twenty-three adult and ten pediatric users of MED-EL CIs participated. The LiveECAPMAPs were compared to behavioral maps (LiveBurstMAPs) and to the participants’ everyday clinical maps (ClinMAPs). Four evaluation measures were considered: average deviations of the maximum comfortable loudness (MCL) levels of the LiveECAPMAPs and the LiveBurstMAPs from the MCLs of the ClinMAPs; correlations between the MCLs of the LiveECAPMAPs (MCLecap) and the LiveBurstMAPs (MCLburst) with the MCLs of the ClinMAPs (MCLclin); fitting durations; and speech reception thresholds (SRTs). All evaluation measures were analyzed separately in the adult and pediatric subgroups. For all evaluation measures, the deviations of the LiveECAPMAPs from the ClinMAPs were not larger than those of the LiveBurstMAPs from the ClinMAPs. The Pearson correlation between the MCLecap and the MCLclin across all channels was r2 = 0.732 (p < 0.001) in the adult and r2 = 0.616 (p < 0.001) in the pediatric subgroups. The mean fitting duration in minutes for the LiveECAPMAPs was significantly shorter than for that of the LiveBurstMAPs in both subgroups: adults took 5.70 (range 1.90–11.98) vs. 9.27 (6.83–14.72) min; children took 3.03 (1.97–4.22) vs. 7.35 (3.95–12.77). SRTs measured with the LiveECAPMAPs were non-inferior to those measured with the ClinMAPs and not statistically different to the SRTs measured with the LiveBurstMAPs. ARTFit is a safe, quick, and reliable tool for audiologists to produce ECAP-based initial fitting maps in adults and young children who are not able to provide subjective feedback.

5 March 2021 in Life
Verified
Journal Article
Open access
PDF file
LGLutz Gärtner
Lutz Gärtner
KKKatharina Klötzer
Katharina Klötzer
TLThomas Lenarz
Thomas Lenarz
Verena ScheperVerena Scheper
Verena Scheper
Cochlear implants (CI) are the treatment of choice in profoundly deaf patients. Measuring the electrically evoked compound action potential (ECAP) has become an important tool for verifying the function of the spiral ganglion neurons (SGN), which are the target cells of the CI stimulation. ECAP measurement is only possible after electrode insertion. No information about the neuronal health status is available before cochlear implantation. We investigated possible correlations between the ECAP amplitude growth function (AGF) slope and anamnestic parameters to identify possible predictors for SGN health status and therefore for CI outcome. The study included patients being implanted with various electrode array lengths. Correlation analysis was performed for the mean AGF slope of the whole array, for separate electrodes as well as for grouped electrodes of the apical, medial, and basal region, with duration of deafness, age at implantation, residual hearing (grouped for electrode length), and etiology. The mean ECAP AGF slopes decreased from apical to basal. They were not correlated to the length of the electrode array or any etiology. For the mean of the full array or when grouped for the apical, middle, and basal part, the ECAP AGF slope was negatively correlated to the duration of hearing loss and the age at implantation. Since a significant negative correlation of the ECAP AGF slope and age at cochlear implantation and duration of deafness was observed, this study supports the statement that early implantation of a CI is recommended for sensorineural hearing loss. Additional factors such as the cochlear coverage and insertion angle influence the ECAP AGF slope and performance of the patient and should be included in future multifactorial analysis to study predictive parameters for the CI outcome.