Dur-e-Zehra Baig

Dr. Dur-e-Zehra Baig

Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2022 in IEEE Access
Verified
Journal Article
Open access
MKMuhammad Aseer Khan
Muhammad Aseer Khan
MKMuhammad Arqum Khan
Muhammad Arqum Khan
HAHusan Ali
Husan Ali
BABilal Ashraf
Bilal Ashraf
SKShahbaz Khan
Shahbaz Khan
Tahir KhurshaidTahir Khurshaid
Tahir Khurshaid
With the increase in energy demand, renewable energy has become a need of almost every country. Solar Energy is an important constituent of it and contributes a large portion in it. Forecasting the output power of a Photovoltaic (PV) system has always been a challenging problem in the power sector from the last few decades. The output power of a PV system depends upon several environmental factors such as irradiance (G), temperature (T), humidity (H), wind speed (W), provided the tilt angle is kept constant, among which the vital role is played by irradiance. Researchers have utilized several techniques to accurately predict the output power of PV module but every method has various pros and cons. In this paper, an experimental measurement dataset of 28296 samples with all the environmental parameters mentioned above are taken as the inputs and power as its output, of a Poly-Silicon (Poly-Si) PV module, is trained through Artificial Neural Network (ANN), to predict the output power accurately. The proposed ANN contains a layer size of 15 and training algorithm used is Levenberg-Marquardt. A detailed analysis and preprocessing of the data is carried out through Pearson’s correlation method prior to training. The hyperparameters of Neural Network tuning are selected through heuristic method. The data division is done randomly with 70 % dataset used for training, 15 % dataset used for each validation and testing. The statistical results show that ANN accurately predicted the power output of PV module. The regression analysis values acquired are 98 % and the MSE of all the three phases is 0.0604.

28 October 2024 in Electronics
Verified
Journal Article
Open access
PDF file
FBFarheen Bano
Farheen Bano
Muhammad AyazMuhammad Ayaz
Muhammad Ayaz
DBDur-e-Zehra Baig
Dur-e-Zehra Baig
SRSyed Muhammad Hur Rizvi
Syed Muhammad Hur Rizvi
Ensuring stable power system performance is crucial for reliable grid operation. This study assesses various Load Frequency Control (LFC) strategies, including conventional PID, pole placement, Genetic Algorithm (GA)-optimized PID, Particle Swarm Optimization (PSO)-optimized PID, and an Artificial Neural Network (ANN)-based controller, in single and interconnected power grids. The results reveal that GA- and PSO-optimized PID outperform conventional methods, offering minimal overshoot and fast settling times. Pole placement strikes a balance between response time and stability, while the ANN controller demonstrates adaptability and quick rise times but exhibits higher overshoot and longer settling times compared to the optimization techniques. Tie-line bias control aids in frequency stabilization but presents challenges with overshoot and prolonged settling times. Notably, PSO-optimized PID emerges as a promising solution, effectively mitigating overshoot and achieving rapid frequency recovery. This study underscores the importance of tailored control strategies for optimal LFC, which are essential for enhancing power system stability and efficiency. Future research should explore the potential of advanced techniques, such as deep learning and reinforcement learning, to further improve control performance.

12 March 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMuhammad Aseer Khan
Muhammad Aseer Khan
DBDur-e-Zehra Baig
Dur-e-Zehra Baig
HAHusan Ali
Husan Ali
FAFahad Albogamy
Fahad Albogamy
This study investigates the nonlinear dynamics of Brushless DC (BLDC) motors using the MATLAB/Simulink platform, emphasizing system identification through the Least Squares (LS) method and Nonlinear Autoregressive Network With Exogenous Inputs (NARX) models with variable regressors. Accurate data-driven models derived from these techniques are essential for designing efficient feedback control systems, enabling precise motor dynamics representation and facilitating early fault detection by identifying deviations from normal operation. A detailed simulation of the BLDC motor under no-load conditions is performed to analyze the speed response and ripple effects in torque and speed, underscoring the need for effective modeling and control. Comprehensive datasets are generated to develop LS and NARX models across varying operational conditions. A variable step input voltage signal with both ascending and descending steps is employed for training, while a distinct validation signal of similar trends but different magnitudes is used for performance evaluation. All techniques are benchmarked using identical training and validation signals. Among the models, the NARX model with customized regressors demonstrated superior performance, achieving 99.1% training accuracy and 98.01% validation accuracy in predicting motor dynamics. All the models are further tested under real-time signal conditions like ramp-up acceleration, deceleration, & turning and noisy signal conditions to evaluate the robustness and accuracy of these models in real-world conditions. The findings highlight the NARX model’s potential to enhance control strategies and improve BLDC motor stability, with statistical analysis confirming the robustness and effectiveness of the proposed approach.

7 March 2022 in Processes
Verified
Journal Article
Open access
PDF file
MKMuhammad Aseer Khan
Muhammad Aseer Khan
DBDur-e-Zehra Baig
Dur-e-Zehra Baig
BABilal Ashraf
Bilal Ashraf
HAHusan Ali
Husan Ali
JRJunaid Rashid
Junaid Rashid
JKJungeun Kim
Jungeun Kim
A system identification of a two-wheeled robot (TWR) using a data-driven approach from its fundamental nonlinear kinematics is investigated. The fundamental model of the TWR is implemented in a Simulink environment and tested at various input/output operating conditions. The testing outcome of TWR’s fundamental dynamics generated 12 datasets. These datasets are used for system identification using simple autoregressive exogenous (ARX) and non-linear auto-regressive exogenous (NLARX) models. Initially the ARX structure is heuristically selected and estimated through a single operating condition. We conclude that the single ARX model does not satisfy TWR dynamics for all datasets in term of fitness. However, NLARX fitted the 12 estimated datasets and 2 validation datasets using sigmoid nonlinearity. The obtained results are compared with TWR’s fundamental dynamics and predicted outputs of the NLARX showed more than 98% accuracy at various operating conditions.

1 August 2010
Verified
Conference Paper
Closed access
DBDur-e-Zehra Baig
Dur-e-Zehra Baig
HSHao Su
Hao Su
TCTeddy M. Cheng
Teddy M. Cheng
ASAndrey V. Savkin
Andrey V. Savkin
Steven SuSteven Su
Steven Su
BCBranko G. Celler
Branko G. Celler
The aim of this paper is to study the human Heart Rate (HR) response during walking, cycling and rowing exercises using linear time varying (LTV) models. We used the frequency of exercise locomotion as the input to the model. This frequency characterizes the stride rate, cadence rate and strokes rate of the walking, cycling and rowing exercises respectively. The time varying parameters in the LTV models were estimated by the Kalman Filter (KF). The results in this study demonstrate that HR responses to these exercises exhibit some degree of time varying nature.

23 May 2024
Verified
Conference Paper
Closed access
Muhammad AyazMuhammad Ayaz
Muhammad Ayaz
DBDur-e-Zehra Baig
Dur-e-Zehra Baig
SRSyed Muhammad Hur Rizvi
Syed Muhammad Hur Rizvi
MAMuhammad Akbar
Muhammad Akbar
This study explores Load Frequency Control (LFC) through three distinct strategies, emphasizing the critical role of stable and optimal power system performance in ensuring reliable energy grid operation. In Case 1, without a PID controller, the system experiences characteristics such as a Rise Time of 0.4143 seconds, Settling Time of 6.9202 seconds, a notable Overshoot of 0.9709%, and a Peak Value of 60. Transitioning to Case 2 with Conventional PID control, improvements are evident in parameters like reduced Rise Time (2.3980 × 10 −6 ), shorter Settling Time (4.6951 seconds), negligible Overshoot (0.0016%), and a Peak Value of 60.0001. In Case 3, employing Particle Swarm Optimization (PSO)-optimized PID control showcases exceptional performance with a remarkable Rise Time (3.0765 ×10 −10 ), swift Settling Time (1.5093 seconds), minimal Overshoot (9.8068 ×10 −5 %), and a Peak Value of 60.0001 at 2.9381 seconds. These outcomes highlight the efficacy of PSO-optimized PID control in achieving rapid response, minimal overshoot, and heightened stability, providing valuable insights for optimizing power system stability in interconnected grids.