Joshua Anani

Mr. Joshua Anani

Egypt-Japan University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2022 in Polymers
Verified
Journal Article
Open access
Joshua AnaniJoshua Anani
Joshua Anani
HNHussien Noby
Hussien Noby
Abdelrahman ZkriaAbdelrahman Zkria
Abdelrahman Zkria
TYTsuyoshi Yoshitake
Tsuyoshi Yoshitake
Marwa ElkadyMarwa Elkady
Marwa Elkady
Owing to bio-polymer’s low-cost, environmental friendliness and mechanically stable nature, calcium alginate microcapsules have attracted much interest for their applications in numerous fields. Among the common production methods, the Electrospraying technique has shown a great potential due to smaller shape capsule production and ease of control of independent affecting parameters. Although one factor at a time (OFAT) can predict the trends of parameter effect on size and sphericity, it is inefficient in explaining the complex parameter interaction of the electrospray process. In the current study, the effects of the main parameters affecting on size and sphericity of the microcapsules using OFAT were optimized to attain calcium alginate microcapsules with an average diameter below 100 µm. Furthermore, we propose a statistical model employing the Surface Responses Methodology (RSM) and Central Composite Design (CDD) to generate a quadratic order linear regression model for the microcapsule diameter and sphericity coefficient. Experimentally, microcapsules with a size of 92.586 µm and sphericity coefficient of 0.771 were predicted and obtained from an alginate concentration of 2.013 w/v, with a flowrate of 0.560 mL/h, a needle size of 27 G and a 2.024 w/v calcium chloride concentration as optimum parameters. The optimization processes were successfully aligned towards formation of the spherical microcapsules with smaller average diameter of less than 100 µm, owing to the applied high voltage that reached up to 21 kV.

1 February 2024 in International Journal of Chemical Reactor Engineering
Verified
Journal Article
Closed access
Kingsley SafoKingsley Safo
Kingsley Safo
Joshua AnaniJoshua Anani
Joshua Anani
AEAhmed El-shazly
Ahmed El-shazly
This study explores and analyzes the mixing efficiency of five innovative micromixers, each featuring serpentine microchannels, through comprehensive experimentation. The mixing experiments were conducted on micromixers with distinct shapes: backward arrow, loop, square, circular, and box waves, all equipped with backward arrow-shaped inlets, using the Villermaux–Dushman protocol. The assessment of mixing performance was carried out across a range of Reynolds numbers (Re) from 100 to 700, accompanied by varying pressure drop measurements. The efficiency of mixing was determined using ultraviolet spectrophotometry to measure the absorbance values and times for mixed fluids from the five micromixers. At Re values greater than 100, the mixing performance ranked as follows: Square-wave > Circular-wave > Box-wave > Loop-wave > Backward Arrow-shaped micromixers. Factors such as repeated perturbations, the presence of crests and troughs, the angle of the channels, and the split and recombination effects played significant roles in these outcomes. With increasing Re from 100 to 700, we observed progressive and consistent results across all microchannels. Remarkably, at a broad range of Reynolds numbers, the five micromixers demonstrated superior mixing performance compared to designs based on unbalanced split and collisions, achieving an impressive mixing efficiency of over 93 %, while keeping the pressure drop under 80 kPa. This pressure drop range is suitable for a variety of lab-on-a-chip and micro-total analysis systems. Furthermore, the experimental results show that the mixing performance of microfluidic systems can be improved by incorporating the presented design method of microchannel shapes, especially the Square-wave.

14 October 2024 in Journal of Coatings Technology and Research
Verified
Journal Article
Closed access
PDF file
Joshua AnaniJoshua Anani
Joshua Anani
HNHussien Noby
Hussien Noby
Marwa ElkadyMarwa Elkady
Marwa Elkady

26 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Kingsley SafoKingsley Safo
Kingsley Safo
Joshua AnaniJoshua Anani
Joshua Anani
AEAhmed El-shazly
Ahmed El-shazly
This study presents an innovative passive micromixer design featuring convergent–divergent sinusoidal walls, evaluated using the Villermaux–Dushman protocol. Five distinct designs were fabricated and tested, demonstrating superior mixing efficiency without additional obstructions. Testing of flow rates from 1000 to 50 mL/h revealed that the square-wave micromixer had the highest efficiency due to repeated fluid perturbations from its 90-degree angles. The loop-wave mixer performed the worst due to its lack of angles. The circular and box-wave mixers outperformed the loop-wave and backward arrow mixers due to their split and recombination effects. These designs, especially the circular and box-wave designs, offer optimal mixing for short-length applications, improving the efficiency and manufacturing simplicity for biomedical and biochemical analyses.