Yusuke Chiba

Dr. Yusuke Chiba

Iwate Medical University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2019 in JOR SPINE
Verified
Journal Article
Open access
PDF file
YCYusuke Chiba
Yusuke Chiba
HMHideki Murakami
Hideki Murakami
MSMakoto Sasaki
Makoto Sasaki
HEHirooki Endo
Hirooki Endo
DYDaisuke Yamabe
Daisuke Yamabe
MDMinoru Doita
Minoru Doita
Reports on spinal‐implant metallic artifacts in 7‐T magnetic resonance imaging (MRI) are lacking. Thus, we investigated the magnitude of metal artifacts derived from spinal implants in 7‐T MRI and analyzed the differences obtained with spinal rods manufactured from pure titanium, titanium alloy, and cobalt‐chrome (5.5‐mm and 6.0‐mm diameters and 50‐mm length). Following the American Society for Testing and Materials guidelines, we measured the artifact size and artifact volume ratio of each rod during image acquisition using 7‐T MRI scanners with three‐dimensional (3D) T1‐weighted and 3D T2* spoiled gradient echo (GRE), 3D T2‐weighted fast spin echo, zero echo time (ZTE), and diffusion‐weighted imaging sequences. Pure titanium and titanium alloy rods yielded significantly smaller artifacts than did cobalt‐chrome rods, with no significant difference between pure titanium and titanium alloy rods. The artifact sizes of the 5.5‐mm and 6.0‐mm diameter rods were similar. The artifact magnitude increased in the following sequence order: ZTE, 3D T2 fast spin echo, 3D T1 spoiled GRE, 3D T2* spoiled GRE, and diffusion‐weighted imaging. Artifacts obtained using the spin echo method were smaller than those obtained with the GRE method. Because the echo time in ZTE is extremely short, the occurrence of artifacts because of image distortion and signal loss caused by differences in magnetic susceptibility is minimal, resulting in the smallest artifacts. ZTE can be a clinically useful method for the postoperative evaluation of patients after instrumentation surgery, even with 7‐T MRI.

16 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HEHirooki Endo
Hirooki Endo
HMHideki Murakami
Hideki Murakami
DYDaisuke Yamabe
Daisuke Yamabe
YCYusuke Chiba
Yusuke Chiba
RORyosuke Oikawa
Ryosuke Oikawa
MDMinoru Doita
Minoru Doita
We compared radiological and clinical outcomes between multilevel lateral lumbar interbody fusion (LLIF) + hybrid posterior fixation (PF) and multilevel LLIF + conventional open PF in patients with adult spinal deformity (ASD). Patients who underwent minimally invasive surgery for ASD in a single institution between 2014 and 2018 were retrospectively reviewed. Fifty-six patients (hybrid PF, 30; open PF, 26) who underwent ASD correction surgery were enrolled between 2014 and 2018. We evaluated patients’ demographics, clinical outcomes, and radiographical parameters in each group. There was significantly less estimated blood loss in the hybrid PF group (662.8 mL vs. 1088.8 mL; p = 0.012). The CRP level 7 days after surgery was significantly lower in the hybrid PF group (2.9 mg/dL vs. 4.3 mg/dL; p = 0.035). There was no significant difference between the two groups in other demographic variables, visual analog scores for back pain and leg pain, Oswestry Disability Index, coronal Cobb angle, lumbar lordosis, pelvic tilt, pelvic incidence–lumbar lordosis mismatch, and sagittal vertical axis. There was a significantly higher percentage of major complications in the open PF group (42.3% vs. 13.3%; p = 0.039). Thus, LLIF + hybrid PF for ASD corrective surgery may be comparable to LLIF + open PF in terms of clinical and radiographic outcomes.