Alfredo Lanzaro

Dr. Alfredo Lanzaro

Guangzhou University, Guangzhou 510006, China
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Journal of Non-Newtonian Fluid Mechanics
Verified
Journal Article
Closed access
ALAlfredo Lanzaro
Alfredo Lanzaro
XYXue-Feng Yuan
Xue-Feng Yuan

1 April 2017 in Journal of Non-Newtonian Fluid Mechanics
Verified
Journal Article
Closed access
ALAlfredo Lanzaro
Alfredo Lanzaro
DCDaniel Corbett
Daniel Corbett
XYXue-Feng Yuan
Xue-Feng Yuan

13 September 2014 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
ALAlfredo Lanzaro
Alfredo Lanzaro
ZLZhuo Li
Zhuo Li
XYXue-Feng Yuan
Xue-Feng Yuan

14 June 2021 in Molecular Pharmaceutics
Verified
Journal Article
Closed access
ALAlfredo Lanzaro
Alfredo Lanzaro
ARAisling Roche
Aisling Roche
NSNicole Sibanda
Nicole Sibanda
DCDaniel Corbett
Daniel Corbett
PDPeter Davis
Peter Davis
Robin CurtisRobin Curtis
Robin Curtis

1 May 2014 in Journal of Non-Newtonian Fluid Mechanics
Verified
Journal Article
Closed access
ALAlfredo Lanzaro
Alfredo Lanzaro
XYXue-Feng Yuan
Xue-Feng Yuan

24 August 2021 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
ALAlfredo Lanzaro
Alfredo Lanzaro
Subcutaneous injection by means of prefilled syringes allows patients to self-administrate high-concentration (100 g/L or more) protein-based drugs. Although the shear flow of concentrated globulins or monoclonal antibodies has been intensively studied and related to the injection force proper of SC processes, very small attention has been paid to the extensional behavior of this category of complex fluids. This work focuses on the flow of concentrated bovine serum albumin (BSA) solutions through a microfluidic “syringe-on-chip” contraction device which shares some similarities with the geometry of syringes used in SC self-injection. By comparing the velocity and pressure measurements in complex flow with rheometric shear measurements obtained by means of the “Rheo-chip” device, it is shown that the extensional viscosity plays an important role in the injection process of protinaceous drugs. Article Highlights: A microfluidic “syringe on chip” device mimicking the injection flow of protinaceous drugs has been developed. The velocity field of concentrated BSA solutions through the “syringe on chip” is Newtonian-like. The extensional viscosity of concentrated protein solutions should also be considered when computing injection forces through needles.