Renzhi Hu

Dr. Renzhi Hu

Key Laboratory of Environment Optics and Technology, Anhui Institute of Optics and Fine Mechanics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
Xinping YangXinping Yang
Xinping Yang
Keding LuKeding Lu
Keding Lu
XMXuefei Ma
Xuefei Ma
YLYanhui Liu
Yanhui Liu
HWHaichao Wang
Haichao Wang
YZYuanhang Zhang
Yuanhang Zhang

1 March 2022 in Science of The Total Environment
Verified
Journal Article
Closed access
GZGuoxian Zhang
Guoxian Zhang
Renzhi HuRenzhi Hu
Renzhi Hu
PXPinhua Xie
Pinhua Xie
SLShengrong Lou
Shengrong Lou
FWFengyang Wang
Fengyang Wang
WLWenqing Liu
Wenqing Liu

19 March 2019 in Optics Express
Verified
Journal Article
Closed access
FWFengyang Wang
Fengyang Wang
Renzhi HuRenzhi Hu
Renzhi Hu
HCHao Chen
Hao Chen
PXPinhua Xie
Pinhua Xie
YWYihui Wang
Yihui Wang
WLWenqing Liu
Wenqing Liu
A ground-based system for measuring tropospheric OH radical based on laserinduced fluorescence (AIOFM-LIF) was developed in this work. In this system, ambient air is expanded through a 0.4 mm nozzle to low pressure in a detection chamber, where OH radical is irradiated by the 308 nm laser pulse at a repetition rate of 8.5 kHz. Then, the resultant fluorescence corresponding to the A2S (0) X2. (0) i +. =.. = transition at 308 nm is detected using gated photon counting. The AIOFM-LIF system was integrated into a mobile observing platform for the field observation following the series of laboratory characterization. A portable standard OH radical source by water photolysis-ozone actinometry was established and optimized for accurate system calibration. The factors affecting the system sensitivity were quantified. It was shown that the ultimate system sensitivity is 9.9 x 10(-8) cps (molecules cm(-3))-1 mw-1; the minimum detection limits are (1.84 +/- 0.26) x 10(5) cm(-3) and (3.69 +/- 0.52) x 10(5) cm(-3) at night and noon, respectively; and the whole error of AIOFM-LIF system is about 16%. Then, the system was deployed in Shenzhen, China, during the " A comprehensive STudy of the Ozone foRmation Mechanism in Shenzhen" (STORM) campaign. Valid OH radical concentrations for 31 days were obtained, and the peak of the daily average concentration was 6.6 x 10(6) cm(-3) around 12: 00. And a high correlation (R-2 = 0.77) between OH and j(O1D) was also observed in this field campaign. The relationship between OH concentration and NOx was attentively discussed. The deployment of AIOFM-LIF system in STORM campaign has demonstrated its capability of measuring tropospheric OH radical with high sensitivity and accuracy in a polluted environment. (c) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

1 January 2021 in Journal of Environmental Sciences
Verified
Journal Article
Closed access
YWYihui Wang
Yihui Wang
Renzhi HuRenzhi Hu
Renzhi Hu
PXPinhua Xie
Pinhua Xie
HCHao Chen
Hao Chen
FWFengyang Wang
Fengyang Wang
WLWenqing Liu
Wenqing Liu

3 April 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
ZLZhiyan Li
Zhiyan Li
Renzhi HuRenzhi Hu
Renzhi Hu
PXPinhua Xie
Pinhua Xie
HCHao Chen
Hao Chen
SWShengyang Wu
Shengyang Wu
WLWenqing Liu
Wenqing Liu
An inexpensive, compact instrument for sensitive measurement of nocturnal nitrogen oxides NO3 and N2O5 in ambient air at high time resolution has been described. The instrument measures NO3 and N2O5 which is converted into the NO3 radical through thermal decomposition by optical extinction using a diode laser at 662.08 nm in two separate detection channels. The minimum detection limits (1σ) for the NO3 radical and N2O5 are estimated to be 2.3 pptv and 3.1 pptv in an average time of 2.5 s, with the accessible effective absorption path length generally exceeding 30 km, which is sufficient for quantifying NO3 radical and N2O5 concentrations under moderately polluted conditions. The total uncertainties of the NO3 and N2O5 measurements are 8% and 15% respectively, which are mainly dominated by the uncertainty of NO3 across section calculated for 353 K in this system. In addition, the dependence of the instrument’s sensitivity and accuracy on a variety of conditions was presented in winter of 2016 and in summer of 2017 during two China-UK joint campaigns. Distinct N2O5 vertical profiles were observed at night in winter. The equilibrium among observed NO2, NO3 and N2O5 based on the equilibrium constants during summer time also provides confirmation of the measurement accuracy of the instrument.

17 June 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
ZLZhiyan Li
Zhiyan Li
Renzhi HuRenzhi Hu
Renzhi Hu
PXPinhua Xie
Pinhua Xie
HCHao Chen
Hao Chen
XLXiaoyan Liu
Xiaoyan Liu
WLWenqing Liu
Wenqing Liu
Nitric oxide (NO) and nitrogen dioxide (NO2) are relevant to air quality due to their roles in tropospheric ozone (O3) production. In China, NOx emissions are very high and NOx emissions exhausted from on-road vehicles make up 20 % of total NOx emissions. In order to detect the NO and NO2 emissions on road, a dual-channel cavity ring-down spectroscopy (CRDS) system for NO2 and NO detection has been developed. In the system, NO is converted to NO2 by its reaction with excess O3 in the NOx channel, such that NO can be determined through the difference between two channels. The detection limits of NO2 and NOx for the system are estimated to be about 0.030 (1σ, 1 s) and 0.040 ppb (1σ, 1 s), respectively. Considering the error sources of NO2 absorption cross section and RL determination, the total uncertainty of NO2 measurements is about 5%. The performance of the system was validated against a chemiluminescence (CL) analyser (42i, Thermo Scientific, Inc.) by measuring the NO2 standard mixtures. The measurement results of NO2 showed a linear correction factor (R2) of 0.99 in a slope of 1.031±0.006, with an offset of (-0.940±0.323 ) ppb. An intercomparison between the system and a cavity-enhanced absorption spectroscopy (CEAS) instrument was also conducted separately for NO2 measurement in an ambient environment. Least-squares analysis showed that the slope and intercept of the regression line are 1.042±0.002 and (-0.393±0.040 ) ppb, respectively, with a linear correlation factor of R2=0.99. Another intercomparison conducted between the system and the CL analyser for NO detection also showed a good agreement within their uncertainties, with an absolute shift of (0.352±0.013) ppb, a slope of 0.957±0.007 and a correlation coefficient of R2=0.99. The system was deployed on the measurements of on-road vehicle emission plumes in Hefei, and the different emission characteristics were observed in the different areas of the city. The successful deployment of the system has demonstrated that the instrument can provide a new method for retrieving fast variations in NO and NO2 plumes.