Changjie Xu

Dr. Changjie Xu

College of Civil Engineering and Architecture, Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
LTLihong Tong
Lihong Tong
Zhenbo GaoZhenbo Gao
Zhenbo Gao
WHWentao Hu
Wentao Hu
YSYufeng Shi
Yufeng Shi
CXChangjie Xu
Changjie Xu

1 August 2018 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
Yong TanYong Tan
Yong Tan
WJWeizhen Jiang
Weizhen Jiang
WLWenjun Luo
Wenjun Luo
YLYe Lu
Ye Lu
CXChangjie Xu
Changjie Xu
This paper introduces thirteen kinds of typical excavation failures widely encountered in practice in China along with corresponding failure mechanisms and damages to adjacent structures and facilities. Emphasis is placed on investigation of longitudinal slip failure during excavation of subway station, which frequently occurs but rarely receives serious attention. This investigation is based on a sliding event in Hangzhou, China, in which a soft earthen slope about 13 m high inside an uncompleted subway station underwent massive slip failure. Slide debris travelling on sloped terrain caused the detachment of braced steel pipe struts and breakage of interior columns and two concrete struts atop them. Fortunately, an efficient contingency plan was executed right after the event; thus, potential catastrophic collapse of the entire earth supporting system, a domino effect of the massive sliding, was avoided. Postfailure investigations in terms of ground survey, visual inspection, and numerical analyses show that for this three-step earthen slope with an overall slope gradient (including benches) of 1 vertical (V) to 3 horizontal (H) (1V∶3H ), the sliding took place at the uppermost 6-m slope and there was no sign of sliding in the lower 7 m of slopes (1V∶2H ) atop firm to stiff clayey strata. The steep local slope gradient (1V∶1.75H ) of the uppermost slope overlying weak muddy clay was the predominant factor triggering the sliding; probabilistic stability analyses indicate a high slip failure probability of 88.92%. Degradation of soil strength resulting from soil deformation was mitigated by negative excess pore water pressure associated with excavation (unloading); consequently, the uppermost slope did not show signs of potential sliding during the excavation. Following postexcavation dissipation of negative excess pore water pressure accompanied by decreasing of soil shear strength, the uppermost slope underwent an abrupt sliding failure 7 days later. Apart from its recognized effectiveness in limiting lateral wall displacement, quick soil removal was helpful for keeping the soft earthen slope temporarily stable during excavation. To ensure stability of soft earthen slopes underlain by weak subgrades, a slope gradient no steeper than 1V:3H is essential. Based on sensitivity analysis results, optimal slope angles corresponding to strength parameters of soft subsoils are proposed for future excavations. To prevent slip failure of soft earthen slopes, one cost-effective solution is to install recyclable steel sheet pile vertically penetrating through a potential slide at the deepest point of the estimated critical slip surface.

1 September 2018 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
Yong TanYong Tan
Yong Tan
YLYe Lu
Ye Lu
CXChangjie Xu
Changjie Xu
DWDalong Wang
Dalong Wang

3 March 2006 in International Journal for Numerical and Analytical Methods in Geomechanics
Verified
Journal Article
Closed access
PDF file
XGXueyu Geng
Xueyu Geng
CXChangjie Xu
Changjie Xu
YCYuanqiang Cai
Yuanqiang Cai

27 October 2022 in International Journal for Numerical and Analytical Methods in Geomechanics
Verified
Journal Article
Closed access
GFGuohui Feng
Guohui Feng
CXChangjie Xu
Changjie Xu
LLLuju Liang
Luju Liang
MTMing‐Wang Tey
Ming‐Wang Tey
MCMin‐Liang Chi
Min‐Liang Chi
SGShangqi Ge
Shangqi Ge

9 September 2019 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
HZHaiyang Zhuang
Haiyang Zhuang
JRJiawei Ren
Jiawei Ren
MYMiao Yu
Miao Yu
LJLiguo Jing
Liguo Jing
EYErlei Yao
Erlei Yao
CXChangjie Xu
Changjie Xu
With the soil constitutive model developed for the dynamic large deformation of soft soil, a finite element model was constructed to simulate the soil–underground structure static and dynamic coupling interaction system, in which the dynamic contact between soil and underground structure and the dynamic damage of reinforced concrete were considered. The seismic performance and damage mechanism of the large underground subway station in different soil foundations were investigated and evaluated in detail. It was proven that the interaction mechanism between the soil and underground structure would change with the type of soil foundation and the peak acceleration of input ground motion, which can be evaluated by the interaction coefficient between the soils and underground structure. At the same time, some regulations on the seismic performance of underground structure in China code are already unsuitable for evaluating the seismic performance of a large underground subway station in the soft soil foundation or subjected to a strong earthquake, which should be investigate by the specialized time–history analysis method instead. In this study, five seismic performance levels were firstly defined by the inter-storey drift angle of underground structure and corresponding earthquake damage states.