Bo Wang

Bo Wang


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HQHe Qi
He Qi
YZYu ZHOU
Yu ZHOU
ZZZhonghua Zhang
Zhonghua Zhang
BWBo Wang
Bo Wang
YZYi Zhang
Yi Zhang
XWXi Wang
Xi Wang
A ground source heat pump system is a highly efficient renewable heating, cooling, and ventilation system that utilizes the ground as a heat source or sink via ground heat exchangers. Energy pile is an energy geotechnical structure that couples a ground heat exchanger with a geotechnical structure, leading to low capital cost. The design of energy piles can be challengeable due to their complicated geometries and the requirement of mechanical load. This study focuses on the heat transfer across the concrete–soil interface of energy piles in urban areas. Case studies from two projects, the Lambeth College and Shell Centre projects, are presented and discussed. The back analysis of two energy pile cases illustrated that the heat transfer coefficient at the pile–soil interface can differ between the cooling mode and the heating mode. It can be concluded that the difference in the heat transfer coefficient is influenced by a number of factors such as soil properties, concrete (grout) properties, and the installation method.

8 March 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HXHui Xie
Hui Xie
YLYajing Li
Yajing Li
EKErcan Kahya
Ercan Kahya
BWBo Wang
Bo Wang
XGXiyun Ge
Xiyun Ge
GLGuanda Li
Guanda Li
Traffic noise and solid waste pollution are two major problems that restrict urban development and affect urban environments. In this study, a new kind of cement-based material for sound barriers was prepared using industrial waste fly ash cenosphere to explore the material ratio of the sound absorption, sound insulation, and composite layers and to optimize the material’s properties. The research findings showed that the compressive strength had significant effects on the material properties of the sound absorption layer, with the optimal compressive strength range being 0.2–0.4 MPa. At 0.4 MPa, the material with an aggregate-to-binder ratio of 1.0 had the best comprehensive properties. The sound insulation layer had the best compressive strength of 29.00 MPa at a 45% fiber admixture. The composite had the best sound insulation when the thickness ratio of the sound absorption and insulation layers was 60:40, and the sound transmission loss was 38 dB. The embodied carbon (EC) and embodied energy (EE) of the new fly ash cenosphere across the whole life cycle were 57.57 kgCO2e and 477.08 MJ, respectively, which were 4.8−52.9% and 53.2−82.3% lower than other traditional sound barriers, respectively. Thus, they were environmentally friendly and had satisfactory energy-saving and environmental protection values.