The aim of the present study was to describe a 10 years single-centre experience in pacing and defibrillating leads removal using an effective and safe modified mechanical dilatation technique. We developed a single mechanical dilating sheath extraction technique with multiple venous entry site approaches. We performed a venous entry site approach (VEA) in cases of exposed leads and an alternative transvenous femoral approach (TFA) combined with an internal transjugular approach (ITA) in the presence of very tight binding sites causing failure of VEA extraction or in cases of free-floating leads. We attempted to remove 2062 leads [1825 pacing and 237 implantable cardiac defibrillating (ICD) leads; 1989 exposed at the venous entry site and 73 free-floating] in 1193 consecutive patients. The VEA was effective in 1799 leads, the TFA in 28, and the ITA in 205; in the overall population, we completely removed 2032 leads (98.4%), partially removed 18 (0.9%), and failed to remove 12 leads (0.6%). Major complications were observed in eight patients (0.7%), causing three deaths (0.3%). Mechanical single sheath extraction technique with multiple venous entry site approaches is effective, safe, and with a good cost effective profile for pacing and ICD leads removal.
We aimed at describing outcomes and predictors of cardiac avulsion or tear (CA/T) with tamponade and vascular avulsion or tear (VA/T) after transvenous lead extraction (TLE) in the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) registry. A total of 3555 consecutive patients of whom 3510 underwent TLE at 73 centres in 19 European countries were enrolled. Among 58 patients (1.7%) with procedure-related major complications, 49 (84.5%) patients (30 CA/T and 19 VA/T) presented cardiovascular complications requiring pericardiocentesis, chest tube positioning and/or surgical repair. The mortality was 20% in patients with tamponade due to CA/T and 31.6% in patients with VA/T. Pericardiocentesis as first manoeuvre followed by rescue surgical repair was highly effective in case of CA/T (93.8%). At multivariate analysis, CA/T with tamponade was more common in RIATA lead extraction, female patients, leads with a mean dwelling time more than 10 years, and when ≥3 leads were extracted or multiple sheaths required. Occlusion or critical stenosis of superior venous access and the leads mean dwelling time more than 10 years were independent predictors for VA/T, while mechanical dilatation was an independent predictor of a lower incidence of this complication as compared to the use of powered sheaths. In the ELECTRa registry, RIATA lead extraction and superior venous access occlusion/thrombosis are two new independent predictors for cardiac tamponade and major vascular complications, respectively. The use of mechanical sheaths seems to be associated with a lower incidence of VA/T. A strategy of pericardiocentesis followed by a rescue surgical approach seems to be reasonable in order to treat a CA/T with tamponade.