Jorge Flores

Dr. Jorge Flores


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RCRosa Camarillo
Rosa Camarillo
JFJorge Flores
Jorge Flores
PMPedro Marin-Montoya
Pedro Marin-Montoya
GGGuillermo García-Torales
Guillermo García-Torales
JCJuana M. Camarillo-Escobedo
Juana M. Camarillo-Escobedo
Deaths caused by respiratory and cardiovascular diseases have increased by 10%. Every year, exposure to high levels of air pollution is the cause of 7 million premature deaths and the loss of healthy years of life. Air pollution is generally caused by the presence of CO, NO2, NH3, SO2, particulate matter PM10 and PM2.5, mainly emitted by economic activities in large metropolitan areas. The problem increases considerably in the absence of national regulations and the design, installation, and maintenance of an expensive air quality monitoring network. A smart multi-sensor system to monitor air quality is proposed in this work. The system uses an unmanned aerial vehicle and LoRa communication as an alternative for remote and in-situ atmospheric measurements. The instrumentation was integrated modularly as a node sensor to measure the concentration of carbon monoxide (CO), nitrogen dioxide (NO2), ammonia (NH3), sulfur dioxide (SO2), and suspended particulate mass PM10 and PM2.5. The optimal design of the multi-sensor system has been developed under the following constraints: A low weight, compact design, and low power consumption. The integration of the multi-sensor device, UAV, and LoRa communications as a single system adds aeeded flexibility to currently fixed monitoring stations.

11 December 2015 in Applied Optics
Verified
Journal Article
Closed access
PDF file
AFAriel Fernandez
Ariel Fernandez
JFJorge Flores
Jorge Flores
JAJulia R. Alonso
Julia R. Alonso
JFJosé A. Ferrari
José A. Ferrari
We present some pattern recognition applications of a generalized optical Hough transform and the temporal multiplexing strategies for dynamic scale and orientation-variant detection. Unlike computer-based implementations of the Hough transform, in principle its optical implementation does not impose restrictions on the execution time or on the resolution of the images or frame rate of the videos to be processed, which is potentially useful for real-time applications. Validation experiments are presented.

7 October 2011 in Optics Express
Verified
Journal Article
Open access
PDF file
AFAriel Fernandez
Ariel Fernandez
JAJulia R. Alonso
Julia R. Alonso
JFJorge Flores
Jorge Flores
GAGastón A. Ayubi
Gastón A. Ayubi
JMJ. Matías Di Martino
J. Matías Di Martino
JFJosé A. Ferrari
José A. Ferrari
We present a novel optical method for edge enhancement in color images based on the polarization properties of liquid-crystal displays (LCD). In principle, a LCD generates simultaneously two color-complementary, orthogonally polarized replicas of the digital image used as input. The currently viewed image in standard LCD monitors and cell phone’s screens -which we will refer as the “positive image or true-color image”- is the one obtained by placing an analyzer in front of the LCD, in cross configuration to the back polarizer of the display. The orthogonally polarized replica of this image –the “negative image or complementary-color image”- is absorbed by the front polarizer. In order to generate the positive and negative replica with a slight displacement between them, we used a LCD monitor whose analyzer (originally a linear polarizer) was replaced by a calcite crystal acting as beam displacer. When both images are superimposed laterally displaced across the image plane, one obtains an image with enhanced first-order derivatives along a specific direction. The proposed technique works under incoherent illumination and does not require precise alignment, and thus, it could be potentially useful for processing large color images in real-time applications. Validation experiments are presented.

8 February 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
JFJosé A Ferrari
José A Ferrari
JFJorge Flores
Jorge Flores
MLMatías Fernández Lakatos
Matías Fernández Lakatos
GAGastón A Ayubi
Gastón A Ayubi
CPCésar D Perciante
César D Perciante
EFErna Frins
Erna Frins
The purpose of the present work is to compare single-shot phase-retrieval methods based on Hilbert’s transform with Takeda’s spatial linear-carrier method. In addition, we briefly discuss the so-called slightly-off-axis method that involves two interferograms as an efficient way to remove background illumination bias. After carefully analyzing the assumptions implicit in both approaches, we demonstrate that the Hilbert transform based method is completely identical to the 30 years old Takeda’s interferometry with a spatial linear-carrier. Validation experiments are presented.

20 February 2025 in Measurement Science and Technology
Verified
Journal Article
Closed access
JVJesús Villa
Jesús Villa
JFJorge Flores
Jorge Flores
Guillermo Garcia ToralesGuillermo Garcia Torales
Guillermo Garcia Torales
MMManuel Montes-Flores
Manuel Montes-Flores
Processing interferometric images is a key task in optical interferometry for measurement purposes. It is well known that there are two main kinds of interferograms: those with open fringes and those with closed fringes. Often, processing a single interferogram with closed fringes can be challenging; therefore, applying phase-shifting is almost obligatory. However, it requires several images and a high precision mechanical device to achieve accurate results. On the other hand, interferograms with open fringes are more straightforward to process. However, precise knowledge of the carrier frequency of the fringes is essential for accurate processing. An alternative solution to the challenges posed above is the use of digital moiré interferometry, which consists of superimposing a reference interferogram and another obtained with the object to be measured. In this work we propose a digital moiré interferometry method that uses the Fourier transform and Butterworth-type filters. The feasibility and versatility of the proposed method is experimentally demonstrated using a Mach–Zehnder-type interferometer to analyze gas flow in a flame.

21 May 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
RCRosa Camarillo
Rosa Camarillo
JFJorge Flores
Jorge Flores
JCJuana M. Camarillo-Escobedo
Juana M. Camarillo-Escobedo
EHElizabeth Hernandez-Campos
Elizabeth Hernandez-Campos
LGLuis Héctor García-Muñoz
Luis Héctor García-Muñoz
Micromixing is a crucial process in microfluidic systems. In biochemical and chemical analysis, the sample is usually tested with reagents. These solutions must be well mixed for the reaction to be possible, generally using micromixers manufactured with sophisticated and expensive technology. The present work shows the design and evaluation of micromixers fabricated with LTCC (low-temperature co-fired ceramics) and FDM (fused deposition modeling) technologies for the development of functional and complex geometries. Two-dimensional planar serpentine and 3D chaotic convection serpentine micromixers were manufactured and implemented in an automated microanalytical system using photometric methods. To evaluate the performance of the micromixers, flow, mixing and absorbance measurements were carried out. Green tape and PP materials were used and showed good resistance to the acidic chemical solutions. The devices presented achieved mixing times in seconds, a reduced dispersion due to their aspect ratio, high sensitivity, and precision in photometric measurement. The optical sensing cells stored sample volumes in a range of 10 to 600 µL, which allowed the reduction of reagent consumption and waste generation. These are ideal characteristics for in situ measurement, portable, and low-cost applications focused on green chemistry and biochemistry.